  • product_code: VC-234G
  • product_editor_4418_tab_content: <strong>Ethernet Distance Extension</strong> Two VC-234G devices, acting as a standalone pair, are good for Ethernet distance extension over the existing telephone wires. With just one pair of AWG-24 copper wires, you can easily connect two Ethernet networks together with a maximum data rate of 200Mbps. The telephone service can still be used while the VC-234G CO/CPE is in operation. The two solutions listed below are typical applications for the Ethernet over VDSL2 Bridge. <p style="text-align: center;"><img class="img-fluid" src="https://www.planet.com.sa/planet-storage/2025/01/VC-234G-2_L.png" /></p> <strong>MTU/MDU/Hospitality Solution</strong> The VC-234G is a perfect solution to quickly providing cost-effective yet high-speed network services to multi-unit buildings such as residential buildings (multi-dwelling units), commercial (multi-tenant units) buildings, hotels and hospitals. By utilizing the existing telephony infrastructure, network installation is straightforward and requires no new wiring. With up to <strong>200/100Mbps (G.INP, Asym, 8dB)</strong> transmission, VoD, IP telephony and various broadband services can be easily provided. <p style="text-align: center;"><img class="img-fluid" src="https://www.planet.com.sa/planet-storage/2025/01/VC-231G-2_L_1.png" /></p> <strong>Last Mile of FTTx Deployment</strong> The VC-234G is an ideal solution for FTTx (Fiber to the Building, Fiber to the Campus or Fiber to the Node) applications. It supports high-bandwidth VDSL2 over the existing telephone wires in the “last mile” from the telecom or Internet service provider’s fiber node to the buildings and customers’ apartments. The 10/100/1000Mbps port of the VC-234G can be directly connected to a PC or Ethernet devices such as Ethernet switches or broadband routers. It is excellent for phone line network built under Internet because every room or house can use the existing phone line to transmit data through the Internet and the whole building can share the Internet to the wider area network at a minimum cost. <p style="text-align: center;"><img class="img-fluid" src="https://www.planet.com.sa/planet-storage/2025/01/VC-234G-3_L.png" /></p>
  • product_editor_4418_tab_enabled: yes
  • product_editor_4418_tab_content_changed: yes
  • product_editor_4418_tab_title: Applications
  • product_editor_4421_tab_content: <ul type="disc"> <li>ITU-T G.993.5 G.Vector and G.INP</li> <li>DMT-based coding technology</li> <li>Built-in POST splitter to share voice and date</li> <li>One RJ11 connector for VDSL port with VDSL connection</li> <li>One phone connector for telephone connection</li> <li>Voice and data communication can be shared simultaneously based on the existing telephone wire</li> <li>CO/CPE mode selectable via DIP switch</li> <li>Selectable target band plan and SNR margin</li> <li>Up to <strong>200/100Mbps (G.INP, Asym, 8dB)</strong> bandwidth</li> <li>4 10/100/1000BASE-TX LAN ports</li> <li>Complies with IEEE 802.3, 10BASE-T, IEEE 802.3u, 100BASE-TX and IEEE 802.3x, flow control Ethernet standards</li> <li>Half duplex back pressure and IEEE 802.3x full duplex pause frame flow control</li> <li>Supports IEEE 802.1Q VLAN tag transparency</li> <li>VDSL2 stand-alone transceiver for simple bridge modem application</li> <li>Advantage of minimum installation time (Simply Plug-and-Play)</li> <li>Supports extensive LED indicators for network diagnosis</li> <li>Compact in size and easy to install</li> </ul>
  • product_editor_4421_tab_enabled: yes
  • product_editor_4421_tab_content_changed: yes
  • product_editor_4421_tab_title: Key Features
  • product_editor_4422_tab_content:   <div class="table-responsive"> <table class="common_table_sky" style="width: 100%;"> <thead> <tr> <th colspan="2">Hardware Specifications</th> </tr> </thead> <tbody> <tr> <td class="align-middle">LAN Ports</td> <td>4 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports</td> </tr> <tr> <td class="align-middle">VDSL Port</td> <td>1 VDSL2 RJ11 female phone jack Twisted-pair telephone wires (AWG24 or better) up to 1.4km</td> </tr> <tr> <td class="align-middle">Phone Port</td> <td>1 RJ11, built-in splitter for POTS connection</td> </tr> <tr> <td class="align-middle">Dimensions (W x D x H)</td> <td>154.6 x 86.0 x 26.3 mm</td> </tr> <tr> <td class="align-middle">Weight</td> <td>350g</td> </tr> <tr> <td class="align-middle">Power Requirements</td> <td>5V DC, 2A external power</td> </tr> <tr> <td class="align-middle">LED Indicators</td> <td>1 power: <span style="color: green;"><b>Green</b></span> 4 1000BASE-T LNK/ACT: <span style="color: green;"><b>Green</b></span> 4 100BASE-TX LNK/ACK: <span style="color: green;"><b>Green</b></span> 1 VDSL: <span style="color: green;"><b>Green</b></span> 1 CO: <span style="color: green;"><b>Green</b></span> 1 CPE: <span style="color: green;"><b>Green</b></span></td> </tr> <tr> <td class="align-middle">Housing</td> <td>Metal</td> </tr> <tr> <td class="align-middle">DIP Switch & Functionality</td> <td>4-position DIP switch <ul> <li>CO/CPE mode select</li> <li>Selectable G.INP and interleaved mode</li> <li>Selectable target Band plan</li> <li>Selectable target SNR mode</li> </ul> </td> </tr> </tbody> <thead> <tr> <th colspan="2">Switch Specifications</th> </tr> </thead> <tbody> <tr> <td class="align-middle">Switch Processing Scheme</td> <td>Store-and-Forward</td> </tr> <tr> <td class="align-middle">Address Table</td> <td>2K entries</td> </tr> <tr> <td class="align-middle">Flow Control</td> <td>Back pressure for half duplex IEEE 802.3x pause frame for full duplex</td> </tr> <tr> <td class="align-middle">Jumbo Packet Size</td> <td>9K bytes</td> </tr> </tbody> <thead> <tr> <th colspan="2">System Specifications</th> </tr> </thead> <tbody> <tr> <td class="align-middle">VDSL Compliance</td> <td><b>VDSL-DMT</b> ITU-T G.993.1 VDSL ITU-T G.997.1 ITU-T G.993.2 VDSL2 (Profile 17a/30a Support) ITU-T G.993.5 <b>G.vectoring</b> ITU-T G.998 G.INP</td> </tr> <tr> <td class="align-middle">ADSL Compliance</td> <td>Capable of <b>ADSL2/2+</b> standard <ul> <li>ITU G.992.3 G.dmt.bis</li> <li>ITU G.992.5 G.dmt.bisplus</li> </ul> Data Rate: Up to 24Mbps</td> </tr> <tr> <td class="align-middle">Performance* (Downstream/Upstream)</td> <td><b>Interleave, Asym, 8dB</b> 200M ----> 193Mbps/89Mbps 400M ----> 164Mbps/69Mbps 600M ----> 112Mbps/39Mbps 800M ----> 70Mbps/14Mbps 1000M --> 46Mbps/7Mbps 1400M --> 21Mbps/4Mbps<b>Interleave, Sym, 8dB</b> 200M ----> 142Mbps/139Mbps 400M ----> 116Mbps/118Mbps 600M ----> 70Mbps/73Mbps 800M ----> 50Mbps/40Mbps 1000M --> 24Mbps/24Mbps 1400M --> 10Mbps/6Mbps <b>G.INP, Asym, 8dB</b> 200M ----> 200Mbps/100Mbps 400M ----> 170Mbps/68Mbps 600M ---->113Mbps/37Mbps 800M ----> 70Mbps/18Mbps 1000M --> 51Mbps/7Mbps 1400M --> 24Mbps/2Mbps <b>G.INP, Sym, 8dB</b> 200M ----> 150Mbps/150Mbps 400M ----> 120Mbps/126Mbps 600M ----> 73Mbps/78Mbps 800M ----> 48Mbps/43Mbps 1000M --> 27Mbps/26Mbps 1400M --> 10Mbps/5Mbps <b>Interleave, Asym, 12dB</b> 200M ----> 180Mbps/80Mbps 400M ----> 145Mbps/57Mbps 600M ----> 95Mbps/32Mbps 800M ----> 60Mbps/13Mbps 1000M --> 39Mbps/6Mbps 1400M --> 18Mbps/2Mbps <b>Interleave, Sym, 12dB</b> 200M ----> 137Mbps/129Mbps 400M ----> 99Mbps/102Mbps 600M ----> 54Mbps/61Mbps 800M ----> 41Mbps/35Mbps 1000M --> 22Mbps/19Mbps 1400M --> 7Mbps/3Mbps <b>G.INP, Asym, 12dB</b> 200M ----> 185Mbps/90Mbps 400M ----> 150Mbps/60Mbps 600M ----> 94Mbps/36Mbps 800M ----> 61Mbps/14Mbps 1000M --> 44Mbps/6Mbps 1400M --> 21Mbps/1Mbps <b>G.INP, Sym, 12dB</b> 200M ----> 142Mbps/136Mbps 400M ----> 103Mbps/110Mbps 600M ----> 57Mbps/65Mbps 800M ----> 38Mbps/36Mbps 1000M --> 14Mbps/13Mbps 1400M --> 8Mbps/3Mbps <b>*Note: As there are various resistance values in the category of RJ11 cable, the actual data rate will vary on the quality of the copper wire and environmental factors.</b></td> </tr> </tbody> <thead> <tr> <th colspan="2">Standards Conformance</th> </tr> </thead> <tbody> <tr> <td class="align-middle">Standards Compliance</td> <td>IEEE 802.3 Ethernet IEEE 802.3u Fast Ethernet IEEE 802.3ab Gigabit Ethernet IEEE 802.3x Full-duplex flow control IEEE 802.1p Class of Service ITU-T G.993.1 VDSL ITU-T G.997.1 ITU-T G.993.2 VDSL2 (Profile 17a/30a support) ITU-T G.993.5 G.Vectoring & G.INP ITU-T G.998</td> </tr> </tbody> </table> </div>
  • product_editor_4422_tab_enabled: yes
  • product_editor_4422_tab_content_changed: yes
  • product_editor_4422_tab_title: Specifications
  • ekit_post_views_count: 521
  • product_editor_4418_tab_sticky_width: pw-content-1
  • product_editor_4418_tab_sticky_position: pw-left-stick
  • product_editor_4421_tab_sticky_width: pw-content-1
  • product_editor_4421_tab_sticky_position: pw-left-stick
  • product_editor_4422_tab_sticky_width: pw-content-1
  • product_editor_4422_tab_sticky_position: pw-left-stick
  • product_editor_4423_tab_content:
  • product_editor_4423_tab_content_changed: yes
  • product_editor_4423_tab_enabled: yes
  • product_editor_4423_tab_title: Downloads
  • product_editor_4423_tab_sticky_width: pw-content-1
  • product_editor_4423_tab_sticky_height: 1
  • product_editor_4423_tab_sticky_position: pw-left-stick
  • product_editor_4424_tab_content:
  • product_editor_4424_tab_content_changed: yes
  • product_editor_4424_tab_enabled: yes
  • product_editor_4424_tab_title: Related Products
  • product_editor_4424_tab_sticky_width: pw-content-1
  • product_editor_4424_tab_sticky_height: 1
  • product_editor_4424_tab_sticky_position: pw-left-stick
  • total_sales: 0
  • accessories_table: <table class="common_table"> <thead> <tr> <th colspan="2">Ordering Information</th> </tr> </thead> <tbody> <tr> <td class="text-center align-middle"> <h3 class="h6 m-0">VC-234G</h3> </td> <td>4-Port 10/100/1000T Ethernet to VDSL2 Bridge -- 30a profile w/G.vectoring, RJ11</td> </tr> </tbody> </table> <div class="table-responsive"> <div class="table-responsive"> <div class="table-responsive"></div> </div> </div>
  • product_label:
  • prouduct_loop_image_transparent_bg_:
  • 6_features_images:
  • datasheet: 1
  • quick_guide:
  • users_manual: 5
  • ec_declaration_0_date: 20080129
  • ec_declaration_0_version: 1.0
  • ec_declaration_0_description: EC Declaration.
  • ec_declaration_0_download_pdf: https://www.planet.com.sa/storage/products/VC-234G/VC-234G.pdf
  • ec_declaration: 1
  • android_app:
  • driver:
  • firmware:
  • utility:
  • compatible_list:
  • site-sidebar-layout: default
  • ast-site-content-layout: default
  • site-content-style: default
  • site-sidebar-style: default
  • theme-transparent-header-meta: default
  • datasheet_0_date: 20180608
  • datasheet_0_version: 1.0
  • datasheet_0_description: VC-234G
  • datasheet_0_download_pdf: https://www.planet.com.sa/storage/products/VC-234G/C-VC-234G_s.pdf
  • users_manual_0_date: 20241129
  • users_manual_0_version: 1.5
  • users_manual_0_description: Modify contents of user manual.
  • users_manual_0_download_pdf: https://www.planet.com.sa/storage/products/VC-234G/EM-VC-231G%20Series%20Ethernet%20over%20VDSL2%20Brdige_v1.5.pdf
  • users_manual_1_date: 20220520
  • users_manual_1_version: 1.4
  • users_manual_1_description: Modify contents of user manual.
  • users_manual_1_download_pdf: https://www.planet.com.sa/storage/products/VC-234G/EM-VC-231G%20Series%20Ethernet%20over%20VDSL2%20Brdige_v1.4.pdf
  • users_manual_2_date: 20190612
  • users_manual_2_version: 1.2
  • users_manual_2_description: Add VC-231GF.
  • users_manual_2_download_pdf: https://www.planet.com.sa/storage/products/VC-234G/EM-VC-231G%20Series%20Ethernet%20over%20VDSL2%20Brdige_v1.2.pdf
  • users_manual_3_date: 20170908
  • users_manual_3_version: 1.1
  • users_manual_3_description: Content updated.
  • users_manual_3_download_pdf: https://www.planet.com.sa/storage/products/VC-234G/EM-VC-234G-VC-231G_v1.1.pdf
  • users_manual_4_date: 20170615
  • users_manual_4_version: 1.0
  • users_manual_4_description: Initial release.
  • users_manual_4_download_pdf: https://www.planet.com.sa/storage/products/VC-234G/EM-VC-234G-VC-231G_v1.0.pdf
  • astra-migrate-meta-layouts: set
  • applications_tab: <p><strong>Ethernet Distance Extension</strong></p><p>Two VC-234G Bridge can act as a standalone pair which is good for Ethernet distance extension over the existing telephone wires. With just one pair of AWG-24 copper wires, two Ethernet networks can be easily connected to each other with a maximum data transmission rate of 200Mbps. The telephone service can still be used while the VC-234G CO/CPE is in operation. The two solutions listed below are typical applications for the Ethernet over VDSL2 Bridge.</p><p> </p><p><img style="display: block; margin-left: auto; margin-right: auto;" src="https://www.planet.com.sa/planet-storage/2025/01/VC-234G-2_L.png" alt="" width="600" height="568"> </p><p><strong>MTU/MDU/Hospitality Solution</strong></p><p>The VC-234G is a perfect solution to quickly providing cost-effective yet high-speed network services to multi-unit buildings such as residential buildings (multi-dwelling units), commercial (multi-tenant units) buildings, hotels and hospitals. By utilizing the existing telephony infrastructure, a new network installation can be easily built, without requiring new wiring. With a transmission rate of up to <strong>324/60Mbps (G.INP, Asym, 8dB)</strong>, VoD, IP telephony and various broadband services can be easily provided.</p><p> </p><p style="text-align: center;"><img src="https://www.planet.com.sa/planet-storage/2025/01/VC-234G-3_L1.png" alt="" width="600" height="302"></p>
  • key_features_tab: <p><strong>Physical Port</strong></p><ul> <li>Four 10/100/1000BASE-T RJ45 ports with auto MDI/MDI-X function</li> <li>One RJ11 connector for VDSL port with VDSL connection</li> <li>One RJ11 phone connector for telephone connection</li> </ul><p> </p><p><strong>VDSL2 Features</strong></p><ul> <li>ITU-T G.993.2 <strong>VDSL2 Profile 17a/30a/35b</strong> </li> <li>ITU-T G.993.5 G.vectoring and G.INP</li> <li>DMT-based coding technology</li> <li>Built-in POTS splitter to share voice and date</li> <li>CO/CPE mode selectable via DIP switch</li> <li>Selectable target band plan and SNR margin</li> <li>Up to 200/200Mbps bandwidth (in<strong> G.INP, Sym, 8dB</strong> modes)</li> <li>Voice and data communication can be shared simultaneously based on the existing telephone wire</li> <li>Used in pairs to extend Point-to-Point connection up to 1.4km</li> </ul><p> </p><p><strong>Layer 2 Features</strong></p><ul> <li>Complies with IEEE 802.3, 10BASE-T, IEEE 802.3u, 100BASE-TX, IEEE 802.3ab and 1000BASE-T Ethernet standards</li> <li>High-performance Store and Forward architecture, broadcast storm control and runt/CRC filtering eliminate erroneous packets to optimize the network bandwidth</li> <li>Integrated address look-up engine, supporting 1K absolute MAC addresses</li> <li>1522bytes packet size</li> <li>Automatic address learning and address aging</li> <li>IEEE 802.1Q VLAN transparency</li> </ul><p> </p><p><strong>Industrial Case and Installation</strong></p><ul> <li>Metal case</li> <li>Supports extensive LED indicators for network diagnosis</li> <li>External 5V DC, 2A power input socket</li> <li>Wall mounting or desktop installation</li> <li>0 to 50 degrees C operating temperature</li> <li>Advantage of minimum installation time (Simply by Plug-and-Play)</li> </ul>
  • specifications_tab: <table style="width:100%;" class="common_table_sky"><thead><tr><th colspan="2">Hardware Specifications</th></tr></thead><tbody><tr><td class="align-middle">Hardware Version</td><td>2</td></tr><tr><td class="align-middle">LAN Ports</td><td>4 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports</td></tr><tr><td class="align-middle">VDSL Port</td><td>1 VDSL2 RJ11 female phone jack <br /> Twisted-pair telephone wires (AWG-24 or better) up to 1.4km</td></tr><tr><td class="align-middle">Phone Port</td><td>1 RJ11 female phone jack, built-in splitter for POTS connection</td></tr><tr><td class="align-middle">DIP Switch & Functionality</td><td>DIP-1:Select CO or CPE mode.<br /> DIP-2:Select G.INP or Interleaved mode.<br /> DIP-3:Select Band Profile (Asymmetric or Symmetric).<br /> DIP-4:Select SNR of 12dB or 8dB.</td></tr><tr><td class="align-middle">Dimensions (W x D x H)</td><td>154.6 x 86 x 26.3 mm</td></tr><tr><td class="align-middle">Weight</td><td>366g</td></tr><tr><td class="align-middle">Power Requirements</td><td>DC 5V, 2A external power</td></tr><tr><td class="align-middle">Power Consumption/Dissipation</td><td>Max. 2.1 watts / 7.1 BTU (Power on without any connection) <br /> Max. 3.5 watts / 11.9 BTU (Full Loading)</td></tr><tr><td class="align-middle">LED Indicators</td><td>1 x power: <font color="Green"><b>Green</b></font><br /> 4 x 10/100/1000BASE-T LNK/ACT: <font color="Green"><b>Green</b></font><br /> 1 x VDSL: <font color="Green"><b>Green</b></font><br /> 1 x CO: <font color="Green"><b>Green</b></font><br /> 1 x CPE: <font color="Green"><b>Green</b></font></td></tr><tr><td class="align-middle">Housing</td><td>Metal</td></tr></tbody><thead><tr><th colspan="2">Switch Specifications</th></tr></thead><tbody><tr><td class="align-middle">Switch Processing Scheme</td><td>Store-and-Forward</td></tr><tr><td class="align-middle">Address Table</td><td>1K entries</td></tr><tr><td class="align-middle">Maximum Packet Size</td><td>1522bytes</td></tr></tbody><thead><tr><th colspan="2">Standards Conformance</th></tr></thead><tbody><tr><td class="align-middle">VDSL Compliance</td><td>VDSL-DMT<br />  ITU-T G.993.1 VDSL<br />  ITU-T G.997.1<br />  ITU-T G.993.2 VDSL2 (Profile 17a/30a/35b support)<br />  ITU-T G.993.5 G.vectoring<br />  ITU-T G.998<br />  G.INP</td></tr><tr><td class="align-middle">ADSL Compliance</td><td>Capable of ADSL2/2+ standard<br />  ITU G.992.3 G.dmt.bis<br />  ITU G.992.5 G.dmt.bisplus<br /> Data Rate: Up to 24Mbps</td></tr><tr><td class="align-middle">Standards Compliance</td><td>IEEE 802.3 Ethernet <br /> IEEE 802.3u Fast Ethernet<br /> IEEE 802.3ab Gigabit Ethernet<br /> IEEE 802.1p Class of Service<br /> ITU-T G.993.1 VDSL<br /> ITU-T G.997.1<br /> ITU-T G.993.2 VDSL2 (Profile 17a/30a/35b support)<br /> ITU-T G.993.5 G.Vectoring & G.INP<br /> ITU-T G.998</td></tr><tr><td class="align-middle">Regulatory Compliance</td><td>FCC Part 15 Class A, CE</td></tr></tbody><thead><tr><th colspan="2">Environment</th></tr></thead><tbody><tr><td class="align-middle">Temperature</td><td>Operating: 0~50 degrees C<br /> Storage: -10~70 degrees C</td></tr><tr><td class="align-middle">Humidity</td><td>Operating: 5~95% (non-condensing)<br /> Storage: 5~95% (non-condensing)</td></tr></tbody><thead><tr><th colspan="2">Performance</th></tr></thead><tbody><tr><td class="align-middle">RJ11 Performance*(Downstream/Upstream)</td><td><table width="417" border="1" cellspacing="0" cellpadding="0"><tr><td width="56" rowspan="3"><div align="center">Distance<br>(meter)</div></td><td colspan="4"><div align="center">Interleave<br>(Downstream/Upstream: Mbps)</div></td></tr><tr><td colspan="2"><div align="center"> Asymmetric</div></td><td colspan="2"><div align="center">Symmetric</div></td></tr><tr><td width="123"><div align="center">8dB</div></td><td width="123"><div align="center">12dB</div></td><td width="123"><div align="center">8dB</div></td><td width="123"><div align="center">12dB</div></td></tr><tr><td bgcolor="#FFFFFF"><div align="center">200m</div></td><td bgcolor="#FFFFFF"><div align="center">253/56</div></td><td bgcolor="#FFFFFF"><div align="center">260/53</div></td><td bgcolor="#FFFFFF"><div align="center">181/173</div></td><td bgcolor="#FFFFFF"><div align="center">172/164</div></td></tr><tr><td bgcolor="#FFFFFF"><div align="center">400m</div></td><td bgcolor="#FFFFFF"><div align="center">229/52</div></td><td bgcolor="#FFFFFF"><div align="center">200/51</div></td><td bgcolor="#FFFFFF"><div align="center">147/140/div></td><td bgcolor="#FFFFFF"><div align="center">136/123</div></td></tr><tr><td bgcolor="#FFFFFF"><div align="center">600m</div></td><td bgcolor="#FFFFFF"><div align="center">112/42</div></td><td bgcolor="#FFFFFF"><div align="center">99/39</div></td><td bgcolor="#FFFFFF"><div align="center">95/78</div></td><td bgcolor="#FFFFFF"><div align="center">77/64</div></td></tr><tr><td bgcolor="#FFFFFF"><div align="center">800m</div></td><td bgcolor="#FFFFFF"><div align="center">108/33</div></td><td bgcolor="#FFFFFF"><div align="center">77/28</div></td><td bgcolor="#FFFFFF"><div align="center">72/51</div></td><td bgcolor="#FFFFFF"><div align="center">59/40</div></td></tr><tr><td bgcolor="#FFFFFF"><div align="center">1000m</div></td><td bgcolor="#FFFFFF"><div align="center">71/51</div></td><td bgcolor="#FFFFFF"><div align="center">60/12</div></td><td bgcolor="#FFFFFF"><div align="center">51/27</div></td><td bgcolor="#FFFFFF"><div align="center">47/24</div></td></tr><tr><td bgcolor="#FFFFFF"><div align="center">1200m</div></td><td bgcolor="#FFFFFF"><div align="center">43/9</div></td><td bgcolor="#FFFFFF"><div align="center">35/6</div></td><td bgcolor="#FFFFFF"><div align="center">29/25</div></td><td bgcolor="#FFFFFF"><div align="center">24/20</div></td></tr><tr><td bgcolor="#FFFFFF"><div align="center">1400m</div></td><td bgcolor="#FFFFFF"><div align="center">26/7</div></td><td bgcolor="#FFFFFF"><div align="center">23/6</div></td><td bgcolor="#FFFFFF"><div align="center">19/13</div></td><td bgcolor="#FFFFFF"><div align="center">18/11</div></td></tr><td width="56" rowspan="3"><div align="center">Distance<br>(meter)</div></td><td colspan="4"><div align="center"> G.INP<br>(Downstream/Upstream: Mbps)</div></td></tr><tr><td colspan="2"><div align="center"> Asymmetric</div></td><td colspan="2"><div align="center">Symmetric</div></td></tr><tr><td width="123"><div align="center">8dB</div></td><td width="123"><div align="center">12dB</div></td><td width="123"><div align="center">8dB</div></td><td width="123"><div align="center">12dB</div></td><tr><td bgcolor="#FFFFFF"><div align="center">200m</div></td><td bgcolor="#FFFFFF"><div align="center">308/55</div></td><td bgcolor="#FFFFFF"><div align="center">285/53</div></td><td bgcolor="#FFFFFF"><div align="center">191/186</div></td><td bgcolor="#FFFFFF"><div align="center">183/175</div></td></tr><tr><td bgcolor="#FFFFFF"><div align="center">400m</div></td><td bgcolor="#FFFFFF"><div align="center">246/55</div></td><td bgcolor="#FFFFFF"><div align="center">211/52</div></td><td bgcolor="#FFFFFF"><div align="center">143/141</div></td><td bgcolor="#FFFFFF"><div align="center">140/124</div></td><tr><td bgcolor="#FFFFFF"><div align="center">600m</div></td><td bgcolor="#FFFFFF"><div align="center">125/43</div></td><td bgcolor="#FFFFFF"><div align="center">96/40</div></td><td bgcolor="#FFFFFF"><div align="center">88/81</div></td><td bgcolor="#FFFFFF"><div align="center">99/39</div></td></tr><tr><td bgcolor="#FFFFFF"><div align="center">800m</div></td><td bgcolor="#FFFFFF"><div align="center">108/33</div></td><td bgcolor="#FFFFFF"><div align="center">77/28</div></td><td bgcolor="#FFFFFF"><div align="center">72/51</div></td><td bgcolor="#FFFFFF"><div align="center">59/40</div></td></tr><tr><td bgcolor="#FFFFFF"><div align="center">1000m</div></td><td bgcolor="#FFFFFF"><div align="center">71/15</div></td><td bgcolor="#FFFFFF"><div align="center">60/12</div></td><td bgcolor="#FFFFFF"><div align="center">51/27</div></td><td bgcolor="#FFFFFF"><div align="center">47/24</div></td></tr><tr><td bgcolor="#FFFFFF"><div align="center">1200m</div></td><td bgcolor="#FFFFFF"><div align="center">43/9</div></td><td bgcolor="#FFFFFF"><div align="center">35/6</div></td><td bgcolor="#FFFFFF"><div align="center">29/25</div></td><td bgcolor="#FFFFFF"><div align="center">24/20</div></td></tr><tr><td bgcolor="#FFFFFF"><div align="center">1400m</div></td><td bgcolor="#FFFFFF"><div align="center">33/6</div></td><td bgcolor="#FFFFFF"><div align="center">35/4</div></td><td bgcolor="#FFFFFF"><div align="center">24/15</div></td><td bgcolor="#FFFFFF"><div align="center">20/17</div></td></tr></table>* The performance data above is for reference only. The actual data rate will vary on the quality of the copper wire and environmental factors.</td></tr></tbody></table>
  • rank_math_news_sitemap_robots: index
  • rank_math_robots: a:1:{i:0;s:5:"index";}
  • rank_math_internal_links_processed: 1

4-Port 10/100/1000T Ethernet to VDSL2 Bridge (35b profile w/ G.vector)

» VC-234G

200/200Mbps Downstream/Upstream, High-performance Gigabit Ethernet over Phone Wire Solution 

PLANET VC-234G, a new-generation and high-performance Gigabit Ethernet-over-VDSL2 Bridge with the brand-new VDSL2 Super Vector 35b profile, works well with a pervasive telephone line network with a symmetric data rate of up to 200/200Mbps (G.INP, Sym, 8dB) over a distance of 200m and 25/16Mbps over a long distance of 1.4km. It is based on the two-core networking technology, Gigabit Ethernet and VDSL2 (Very-high-data-rate Digital Subscriber Line 2). The VDSL2 technology offers absolutely the fastest data transmission speed over the existing copper telephone lines without the need of rewiring. 

 

High-performance Ethernet over VDSL2 Transmission

Via the latest VDSL2 technology, PLANET VC-234G offers high-speed access to Internet, up to 200Mbps for both upstream and downstream data transmissions. With integrated support for the ITU-T’s new G.993.5 vectoring technology, the VC-234G

offers a stable yet high-speed point-to-point network access up to a duplex data transmission rate of 300Mbps. It provides 2 selective transmission modes — asymmetric mode or symmetric mode — for the transmission of upstream and downstream signals. 

  • Asymmetric mode – downstream up to 300Mbps and upstream up to 100Mbps
  • Symmetric mode – downstream up to 200Mbps and upstream up to 200Mbps

The symmetric mode provides similar transmission rate on both downstream and upstream while the asymmetric mode performs higher transmission quality in short range. In all, when the VC-234G is in the symmetric mode, it provides a better upstream performance, and when it is in the asymmetric mode, it gives a better downstream performance. It also works in conjunction with vectoring-enabled DSLAMs to remove crosstalk interference and improve maximum line bandwidth across the existing copper infrastructure.

 

Implementing with Existing Telephone Copper Wires

The VC-234G is also a Long Reach Ethernet (LRE) Bridge providing four RJ45 Ethernet ports and two RJ11 phone jacks, in which one is for VDSL connection and the other one is for POTS (Plain Old Telephone Service) connection. The VC-234G has a built-in POTS splitter to share the existing phone line with POTS; therefore, there is no need to replace the existing copper wiring. Just plug the VC-234G into the existing RJ11 telephone jack and a high-performance VDSL2 network can be connected. The VC-234G is ideal to be used as an Ethernet extender to an existing Ethernet network.

 

 

Delivering High-demanding Service Connectivity for ISP/Triple Play Devices

The VC-234G provides an excellent bandwidth demand for the triple play devices for home entertainment and communication. With the asymmetric data transmission of 324/60Mbps (G.INP, Asym, 8dB), the VC-234G enables many multi-media services to work on the local Internet, such as VoD (video on demand), voice over IP, video phone, IPTV, Internet caching server, distance education, and so on, which is ideal for the following network applications:

  • Long-distance IP network devices
  • IP digital signage 
  • Cable TV to IPTV
  • Distance video education
  • Electronic billboards
  • Other applications 

 

 

 

Easy and Flexible Installation 

The Ethernet-over-VDSL2 Bridge comes with a plug-and-play design and is fully compatible with all kinds of network protocols. Moreover, the operating status of each individual port and the whole system can be watched via the rich diagnostic LEDs on the front panel. The VC-234G offers two modes, CPE and CO, for application — CPE mode is used at client side and CO mode is at central side. The CPE or CO mode can be adjusted by using a built-in DIP switch. For point-to-point connection, a CPE mode VC-234G and a CO mode VC-234G must be set up as one pair of Bridges to perform the connection.

 

ADSL2+ Fallback

For those ISPs that still provide ADSL broadband service, the VC-234G can support transmission rates up to 24Mbps downstream and 1Mbps upstream with the ADSL2+ technology. The VC-234G establishes a connection with ISP and can be also directly switched over to VDSL2 after the ISP network upgrade.

Ethernet Distance Extension

Two VC-234G Bridge can act as a standalone pair which is good for Ethernet distance extension over the existing telephone wires. With just one pair of AWG-24 copper wires, two Ethernet networks can be easily connected to each other with a maximum data transmission rate of 200Mbps. The telephone service can still be used while the VC-234G CO/CPE is in operation. The two solutions listed below are typical applications for the Ethernet over VDSL2 Bridge.

 

 

MTU/MDU/Hospitality Solution

The VC-234G is a perfect solution to quickly providing cost-effective yet high-speed network services to multi-unit buildings such as residential buildings (multi-dwelling units), commercial (multi-tenant units) buildings, hotels and hospitals. By utilizing the existing telephony infrastructure, a new network installation can be easily built, without requiring new wiring. With a transmission rate of up to 324/60Mbps (G.INP, Asym, 8dB), VoD, IP telephony and various broadband services can be easily provided.

 

Physical Port

  • Four 10/100/1000BASE-T RJ45 ports with auto MDI/MDI-X function
  • One RJ11 connector for VDSL port with VDSL connection
  • One RJ11 phone connector for telephone connection

 

VDSL2 Features

  • ITU-T G.993.2 VDSL2 Profile 17a/30a/35b 
  • ITU-T G.993.5 G.vectoring and G.INP
  • DMT-based coding technology
  • Built-in POTS splitter to share voice and date
  • CO/CPE mode selectable via DIP switch
  • Selectable target band plan and SNR margin
  • Up to 200/200Mbps bandwidth (in G.INP, Sym, 8dB modes)
  • Voice and data communication can be shared simultaneously based on the existing telephone wire
  • Used in pairs to extend Point-to-Point connection up to 1.4km

 

Layer 2 Features

  • Complies with IEEE 802.3, 10BASE-T, IEEE 802.3u, 100BASE-TX, IEEE 802.3ab and 1000BASE-T Ethernet standards
  • High-performance Store and Forward architecture, broadcast storm control and runt/CRC filtering eliminate erroneous packets to optimize the network bandwidth
  • Integrated address look-up engine, supporting 1K absolute MAC addresses
  • 1522bytes packet size
  • Automatic address learning and address aging
  • IEEE 802.1Q VLAN transparency

 

Industrial Case and Installation

  • Metal case
  • Supports extensive LED indicators for network diagnosis
  • External 5V DC, 2A power input socket
  • Wall mounting or desktop installation
  • 0 to 50 degrees C operating temperature
  • Advantage of minimum installation time (Simply by Plug-and-Play)
Hardware Specifications
Hardware Version2
LAN Ports4 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports
VDSL Port1 VDSL2 RJ11 female phone jack
Twisted-pair telephone wires (AWG-24 or better) up to 1.4km
Phone Port1 RJ11 female phone jack, built-in splitter for POTS connection
DIP Switch & FunctionalityDIP-1:Select CO or CPE mode.
DIP-2:Select G.INP or Interleaved mode.
DIP-3:Select Band Profile (Asymmetric or Symmetric).
DIP-4:Select SNR of 12dB or 8dB.
Dimensions (W x D x H)154.6 x 86 x 26.3 mm
Weight366g
Power RequirementsDC 5V, 2A external power
Power Consumption/DissipationMax. 2.1 watts / 7.1 BTU (Power on without any connection)
Max. 3.5 watts / 11.9 BTU (Full Loading)
LED Indicators1 x power: Green
4 x 10/100/1000BASE-T LNK/ACT: Green
1 x VDSL: Green
1 x CO: Green
1 x CPE: Green
HousingMetal
Switch Specifications
Switch Processing SchemeStore-and-Forward
Address Table1K entries
Maximum Packet Size1522bytes
Standards Conformance
VDSL ComplianceVDSL-DMT
 ITU-T G.993.1 VDSL
 ITU-T G.997.1
 ITU-T G.993.2 VDSL2 (Profile 17a/30a/35b support)
 ITU-T G.993.5 G.vectoring
 ITU-T G.998
 G.INP
ADSL ComplianceCapable of ADSL2/2+ standard
 ITU G.992.3 G.dmt.bis
 ITU G.992.5 G.dmt.bisplus
Data Rate: Up to 24Mbps
Standards ComplianceIEEE 802.3 Ethernet
IEEE 802.3u Fast Ethernet
IEEE 802.3ab Gigabit Ethernet
IEEE 802.1p Class of Service
ITU-T G.993.1 VDSL
ITU-T G.997.1
ITU-T G.993.2 VDSL2 (Profile 17a/30a/35b support)
ITU-T G.993.5 G.Vectoring & G.INP
ITU-T G.998
Regulatory ComplianceFCC Part 15 Class A, CE
Environment
TemperatureOperating: 0~50 degrees C
Storage: -10~70 degrees C
HumidityOperating: 5~95% (non-condensing)
Storage: 5~95% (non-condensing)
Performance
RJ11 Performance*(Downstream/Upstream)
Distance
(meter)
Interleave
(Downstream/Upstream: Mbps)
Asymmetric
Symmetric
8dB
12dB
8dB
12dB
200m
253/56
260/53
181/173
172/164
400m
229/52
200/51
147/140/div>
136/123
600m
112/42
99/39
95/78
77/64
800m
108/33
77/28
72/51
59/40
1000m
71/51
60/12
51/27
47/24
1200m
43/9
35/6
29/25
24/20
1400m
26/7
23/6
19/13
18/11
Distance
(meter)
G.INP
(Downstream/Upstream: Mbps)
Asymmetric
Symmetric
8dB
12dB
8dB
12dB
200m
308/55
285/53
191/186
183/175
400m
246/55
211/52
143/141
140/124
600m
125/43
96/40
88/81
99/39
800m
108/33
77/28
72/51
59/40
1000m
71/15
60/12
51/27
47/24
1200m
43/9
35/6
29/25
24/20
1400m
33/6
35/4
24/15
20/17
* The performance data above is for reference only. The actual data rate will vary on the quality of the copper wire and environmental factors.
DateVersionDescriptionDownload
2018/08/061.0

VC-234G

Download Icon
DateVersionDescriptionDownload
2024/29/111.5

Modify contents of user manual.

Download Icon
2022/20/051.4

Modify contents of user manual.

Download Icon
2019/12/061.2

Add VC-231GF.

Download Icon
2017/08/091.1

Content updated.

Download Icon
2017/15/061.0

Initial release.

Download Icon
DateVersionDescriptionDownload
2008/29/011.0

EC Declaration.

Download Icon

Ordering Information

VC-234G

4-Port 10/100/1000T Ethernet to VDSL2 Bridge (35b profile w/ G.vector)

Ordering Information

VC-234G

4-Port 10/100/1000T Ethernet to VDSL2 Bridge -- 30a profile w/G.vectoring, RJ11

Subscribe to PLANET e Newsletter

Receive the latest product information and company news!