Product Meta

  • product_editor_4418_tab_content: <strong>Access Control System – Traditional System Application</strong> Most of the enterprises and government use access control plate and Mifare or RFID to authorize entrance identity. Traditionally, the access control machines use RS232 or RS485 serial interface with their cables connecting to login server. By applying the ICS-210xT series Serial Device Server, the access control machine is able to extend the network over longer distances via Ethernet interfaces. In addition, the ICS-210xT series can be linked to an xDSL router to get the internet access capability so that the access control can be set and monitored over the internet. <img class="img-fluid aligncenter" src="https://planet.com.tw/storage/products/49316/ICS-210xT-10.png" alt="" width="700" height="427" />   <strong>Process Control</strong> To monitor, configure and manage the robotic conveyer including other production machines, PLC (Programmable Logical Control) is required to drive the above manufacturing process. The ICS-210xT series can be set to the TCP Server mode and connected to the PLC.  Thus, the administrator can configure and set command settings through Fast Ethernet intranet to remotely control the PLC, without having to stand by the I/O machine. <img class="img-fluid aligncenter" src="https://planet.com.tw/storage/products/49316/ICS-210xT-11.png" alt="" width="700" height="398" /> <strong>Surveillance Motion Control – Pair Connection Mode</strong> Using pair connection mode via the fiber optic patch cord, the ICS-210xT series can extend the distance of the deployed devices via RS232, RS422 and RS485 interfaces, making the remote management of these devices from the monitoring center easier and efficient. <img class="img-fluid aligncenter" src="https://planet.com.tw/storage/products/49316/ICS-210xT-12.png" alt="" width="700" height="246" />
  • product_editor_4418_tab_content_changed: yes
  • product_editor_4418_tab_enabled: yes
  • product_editor_4418_tab_title: Applications
  • product_editor_4418_tab_description: hi
  • product_editor_4418_tab_sticky_width: pw-content-1
  • product_editor_4418_tab_sticky_height: 1
  • product_editor_4418_tab_sticky_position: pw-left-stick
  • product_editor_4421_tab_content_changed: yes
  • product_editor_4421_tab_enabled: yes
  • product_editor_4421_tab_title: Key Features
  • product_editor_4421_tab_sticky_width: pw-content-1
  • product_editor_4421_tab_sticky_height: 1
  • product_editor_4421_tab_sticky_position: pw-left-stick
  • product_editor_4422_tab_content_changed: yes
  • product_editor_4422_tab_enabled: yes
  • product_editor_4422_tab_title: Specifications
  • product_editor_4422_tab_sticky_width: pw-content-1
  • product_editor_4422_tab_sticky_height: 1
  • product_editor_4422_tab_sticky_position: pw-left-stick
  • product_editor_4423_tab_content:
  • product_editor_4423_tab_content_changed: yes
  • product_editor_4423_tab_enabled: yes
  • product_editor_4423_tab_title: Downloads
  • product_editor_4423_tab_sticky_width: pw-content-1
  • product_editor_4423_tab_sticky_height: 1
  • product_editor_4423_tab_sticky_position: pw-left-stick
  • product_editor_4424_tab_content:
  • product_editor_4424_tab_content_changed: yes
  • product_editor_4424_tab_enabled: yes
  • product_editor_4424_tab_title: Related Products
  • product_editor_4424_tab_sticky_width: pw-content-1
  • product_editor_4424_tab_sticky_height: 1
  • product_editor_4424_tab_sticky_position: pw-left-stick
  • total_sales: 0
  • accessories_table: <div class="table-responsive"> <div class="table-responsive"> <div class="table-responsive"> <div class="table-responsive"> <table class="common_table"><thead> <tr> <th colspan="2">Ordering Information</th> </tr> </thead> <tbody> <tr> <td class="text-center align-middle"> <h3 class="h6 m-0">ICS-2105AT</h3> </td> <td>Industrial 1-port RS232/422/485 Serial Device Server with 1-Port 100BASE-FX SFP (-40~75 degrees C)</td> </tr> <tr> <td class="text-center align-middle"> <h3 class="h6 m-0">ICS-2102T</h3> </td> <td>IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100FX SC, MM/2km, -40~75 degrees C)</td> </tr> <tr> <td class="text-center align-middle"> <h3 class="h6 m-0">ICS-2102TS</h3> </td> <td>IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100FX SC, SM/30km, -40~75 degrees C)</td> </tr> </tbody> </table> </div> </div> </div> </div>
  • product_label:
  • product_code: ICS-2105AT / ICS-2102T / ICS-2102TS
  • prouduct_loop_image_transparent_bg_:
  • 6_features_images: a:7:{i:0;s:5:"17606";i:1;s:5:"17607";i:2;s:5:"17608";i:3;s:5:"17609";i:4;s:5:"17610";i:5;s:5:"17611";i:6;s:5:"17612";}
  • datasheet: 1
  • quick_guide: 2
  • users_manual: 2
  • ec_declaration: 1
  • android_app:
  • driver:
  • firmware: 1
  • utility: 1
  • compatible_list:
  • site-sidebar-layout: default
  • ast-site-content-layout: default
  • site-content-style: default
  • site-sidebar-style: default
  • theme-transparent-header-meta: default
  • ekit_post_views_count: 217
  • product_editor_4421_tab_content: Serial Interface <ul type="disc"> <li>One DB9 interface that supports RS232</li> <li>One terminal block interface that supports 2-wire RS485 and 4-wire RS422/RS485 standards</li> <li>Asynchronous serial data rates up to 921600bps</li> <li>Data modes include VCOM, RFC2217, TCP Server, TCP Client, UDP, Remote Pair, Modbus converter server / client and Serial Telnet modes</li> </ul>   Ethernet Interface <ul type="disc"> <li>Choice of fiber-connector from SC/LC, multi-mode/single mode fiber</li> </ul>   Management <ul type="disc"> <li style="list-style-type: none;"> <ul type="disc"> <li>IPv4 and IPv6 dual stack management</li> <li>Remote Management Interfaces</li> </ul> </li> </ul> - IP-based Web management <ul type="disc">- Telnet console management</ul> <ul type="disc">- Windows-based VCOM utility supports searching, monitoring and configuration setting</ul> <ul type="disc"> <li style="list-style-type: none;"> <ul type="disc"> <li>IP NTP (Network Time Protocol) and DNS management</li> <li>Standard TCP/IP interface and versatile operation modes</li> <li>Software Protocol supports ARP, ICMP, TCP/IP, UDP, HTTP server, DHCP client, Telnet server/client</li> <li>Serial Operation mode selected via management interface</li> <li>Pair Connection mode for connecting two serial devices over a network</li> <li>Allows a maximum of 4 hosts to be accessed as TCP client mode</li> <li>Firmware upgrade via HTTP protocol</li> <li>Accessible IP security control to prevent illegal users</li> <li>Event notification</li> </ul> </li> </ul> - Remote Syslog server <ul type="disc">- SNMP trap</ul> <ul type="disc">- Relay output alarm</ul> <ul type="disc"> <li>DHCP client for IP address assignment</li> <li>PLANET Smart Discovery utility automatically finds the client devices on the network</li> </ul>   Industrial Case and Installation <ul type="disc"> <li style="list-style-type: none;"> <ul type="disc"> <li>IP30 metal case</li> <li>DIN-rail and wall-mount designs</li> <li>Redundant power design</li> </ul> </li> </ul> - 9 to 48V DC / 24V AC, redundant power with reverse polarity protection <ul type="disc"> <li>Supports 6000 VDC Ethernet ESD protection</li> <li>-40 to 75 degrees C operating temperature</li> <li>Free fall, shock-proof and vibration-proof for industries</li> <li>Supports extensive LED indicators for network diagnosis</li> <li>Reset button for resetting to factory default</li> </ul>
  • product_editor_4422_tab_content: <table class="common_table_sky"> <thead> <tr> <th colspan="2">Serial Interface</th> </tr> </thead> <tbody> <tr> <td class="align-middle">Serial Ports</td> <td><b>ICS-2105AT</b> 1 x DB9 male for RS232 1 x 4-Pin Terminal block for RS422 / RS485<b>ICS-2102T</b> 1 x DB9 male for RS232 1 x 4-Pin Terminal block for RS422 / RS485<b>ICS-2102TS</b> 1 x DB9 male for RS232 1 x 4-Pin Terminal block for RS422 / RS485</td> </tr> <tr> <td class="align-middle">Serial Standards</td> <td>RS232 / 4-wire RS422 or RS485 / 2-wire RS485</td> </tr> <tr> <td class="align-middle">Baud Rate (Data Rate)</td> <td>50bps to 921Kbps</td> </tr> <tr> <td class="align-middle">Data Bits</td> <td>5, 6, 7, 8</td> </tr> <tr> <td class="align-middle">Parity Type</td> <td>1, 1.5, 2</td> </tr> <tr> <td class="align-middle">Stop Bit</td> <td>Odd, Even, None, Space, Mark</td> </tr> <tr> <td class="align-middle">Flow Control</td> <td>RTS/CTS and DTR/DSR (RS232 only) XON/XOFF</td> </tr> <tr> <td class="align-middle">Signals</td> <td>RS232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND RS422: Tx+, Tx-, Rx+, Rx-, GND 4-wire RS485: Tx+, Tx-, Rx+, Rx-, GND 2-wire RS485: Data A (+), Data B (-), GND</td> </tr> <tr> <td class="align-middle">Pin Assignment</td> <td>Serial Port <table class="table-bordered-bone" cellpadding="6"> <tbody> <tr> <td valign="middle" bgcolor="7f9cd3" width="40"><span style="color: #ffffff;">Pin</span></td> <td valign="middle" bgcolor="7f9cd3" width="100"><span style="color: #ffffff;">RS232</span></td> <td valign="middle" bgcolor="7f9cd3" width="100"><span style="color: #ffffff;">RS422 RS485-4W</span></td> <td valign="middle" bgcolor="7f9cd3" width="100"><span style="color: #ffffff;">RS485-2W</span></td> </tr> <tr> <td valign="middle" bgcolor="edf0f7">1</td> <td valign="middle" bgcolor="FFFFFF">DCD</td> <td valign="middle" bgcolor="FFFFFF">TxD+</td> <td valign="middle" bgcolor="FFFFFF">--</td> </tr> <tr> <td valign="middle" bgcolor="edf0f7">2</td> <td valign="middle" bgcolor="FFFFFF">RxD</td> <td valign="middle" bgcolor="FFFFFF">TxD-</td> <td valign="middle" bgcolor="FFFFFF">--</td> </tr> <tr> <td valign="middle" bgcolor="edf0f7">3</td> <td valign="middle" bgcolor="FFFFFF">TxD</td> <td valign="middle" bgcolor="FFFFFF">RxD-</td> <td valign="middle" bgcolor="FFFFFF">Data-</td> </tr> <tr> <td valign="middle" bgcolor="edf0f7">4</td> <td valign="middle" bgcolor="FFFFFF">DTR</td> <td valign="middle" bgcolor="FFFFFF">RxD+</td> <td valign="middle" bgcolor="FFFFFF">Data+</td> </tr> <tr> <td valign="middle" bgcolor="edf0f7">5</td> <td valign="middle" bgcolor="FFFFFF">GND</td> <td valign="middle" bgcolor="FFFFFF">GND</td> <td valign="middle" bgcolor="FFFFFF">GND</td> </tr> <tr> <td valign="middle" bgcolor="edf0f7">6</td> <td valign="middle" bgcolor="FFFFFF">DSR</td> <td valign="middle" bgcolor="FFFFFF">--</td> <td valign="middle" bgcolor="FFFFFF">--</td> </tr> <tr> <td valign="middle" bgcolor="edf0f7">7</td> <td valign="middle" bgcolor="FFFFFF">RTS</td> <td valign="middle" bgcolor="FFFFFF">--</td> <td valign="middle" bgcolor="FFFFFF">--</td> </tr> <tr> <td valign="middle" bgcolor="edf0f7">8</td> <td valign="middle" bgcolor="FFFFFF">CTS</td> <td valign="middle" bgcolor="FFFFFF">--</td> <td valign="middle" bgcolor="FFFFFF">--</td> </tr> <tr> <td valign="middle" bgcolor="edf0f7">9</td> <td valign="middle" bgcolor="FFFFFF">--</td> <td valign="middle" bgcolor="FFFFFF">--</td> <td valign="middle" bgcolor="FFFFFF">--</td> </tr> </tbody> </table> 4-pin Terminal Block <table class="table-bordered-bone" cellpadding="6"> <tbody> <tr> <td align="center" valign="middle" bgcolor="7f9cd3" width="40"><span style="color: #ffffff;">Pin</span></td> <td align="center" valign="middle" bgcolor="7f9cd3" width="100"><span style="color: #ffffff;">RS422 RS485-4W</span></td> <td align="center" valign="middle" bgcolor="7f9cd3" width="100"><span style="color: #ffffff;">RS485-2W</span></td> </tr> <tr> <td align="center" valign="middle" bgcolor="edf0f7">1</td> <td valign="middle" bgcolor="FFFFFF">TxD+(A)</td> <td valign="middle" bgcolor="FFFFFF">--</td> </tr> <tr> <td align="center" valign="middle" bgcolor="edf0f7">2</td> <td valign="middle" bgcolor="FFFFFF">TxD-(B)</td> <td valign="middle" bgcolor="FFFFFF">--</td> </tr> <tr> <td align="center" valign="middle" bgcolor="edf0f7">3</td> <td valign="middle" bgcolor="FFFFFF">RxD-(B)</td> <td valign="middle" bgcolor="FFFFFF">Data-(B)</td> </tr> <tr> <td align="center" valign="middle" bgcolor="edf0f7">4</td> <td valign="middle" bgcolor="FFFFFF">RxD+(A)</td> <td valign="middle" bgcolor="FFFFFF">Data+(A)</td> </tr> </tbody> </table> </td> </tr> </tbody> <thead> <tr> <th colspan="2">Ethernet Interface</th> </tr> </thead> <tbody> <tr> <td class="align-middle">Ethernet Ports</td> <td>ICS-2105AT: 1 x SFP ICS-2102T/ICS-2102TS: 1 x Duplex SC</td> </tr> <tr> <td class="align-middle">Standard</td> <td>100BASE-FX</td> </tr> <tr> <td class="align-middle">Connector</td> <td>ICS-2105AT: LC ICS-2102T/ICS-2102TS: Duplex SC</td> </tr> <tr> <td class="align-middle">Fiber Mode</td> <td>ICS-2105AT: Single mode or multi-mode (may vary on SFP module) ICS-2102T: Multi-mode ICS-2102TS: Single mod</td> </tr> <tr> <td class="align-middle">Transmission Mode</td> <td>Full duplex</td> </tr> <tr> <td class="align-middle">Distance</td> <td>ICS-2105AT: 2km to 120km (may vary on SFP module) ICS-2102T: 2km ICS-2102TS: 30km</td> </tr> <tr> <td class="align-middle">Cable</td> <td>ICS-2105AT: 50 or 62.5/125μm multi-mode fiber cable 9/125μm single-mode cableICS-2102T: 50/125μm or 62.5/125μm multi-mode fiber cableICS-2102TS: 9/125μm single-mode cable</td> </tr> <tr> <td class="align-middle">ESD Protection</td> <td>6KV</td> </tr> <tr> <td class="align-middle">Surge Protection</td> <td>2KV</td> </tr> </tbody> <thead> <tr> <th colspan="2">Hardware</th> </tr> </thead> <tbody> <tr> <td class="align-middle">Installation</td> <td>DIN-rail kit and wall-mount ear</td> </tr> <tr> <td class="align-middle">Enclosure</td> <td>IP 30 metal</td> </tr> <tr> <td class="align-middle">Dimensions (W x D x H)</td> <td>32 x 87.8 x 135 mm</td> </tr> <tr> <td class="align-middle">Weight</td> <td>ICS-2105AT: 390g ICS-2102T: 386g ICS-2102TS: 391g</td> </tr> <tr> <td class="align-middle">LED Indicators</td> <td>System: Power 1, Power 2, Fault, SYS SFP: Link/Active Serial Port: Tx and Rx</td> </tr> <tr> <td class="align-middle">Power Requirements</td> <td>9~48V DC / 24V AC, redundant power with reverse polarity protection</td> </tr> <tr> <td class="align-middle">Power Consumption</td> <td><b>ICS-2105AT:</b> Full Loading 9VDC: 0.44A (3.96 watts) 12VDC: 0.33A (4 watts) 24VDC: 0.17A (4.08 watts) 48VDC: 0.1A (4.8 watts)<b>ICS-2102T:</b> Full Loading 9VDC: 0.56A (5 watts) 12VDC: 0.42A (5 watts) 24VDC: 0.23A (5.5 watts) 48VDC: 0.13A (6 watts)<b>ICS-2102TS:</b> Full Loading 9VDC: 0.56A (5 watts) 12VDC: 0.42A (5 watts) 24VDC: 0.23A (5.5 watts) 48VDC: 0.13A (6 watts)</td> </tr> <tr> <td class="align-middle">Connector</td> <td>Removable 6-pin terminal block for power input Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin 5/6 for Power 2</td> </tr> <tr> <td class="align-middle">Alarm</td> <td>Provides one relay output for power failure Alarm relay current carry ability: 1A @ DC 24V</td> </tr> <tr> <td class="align-middle">Reset Button</td> <td>< 5 sec: System reboot > 5 sec: Factory default</td> </tr> </tbody> <thead> <tr> <th colspan="2">Management</th> </tr> </thead> <tbody> <tr> <td class="align-middle">Management Interfaces</td> <td>Web management Telnet Console management Windows-based VCOM Utility management SNMPv1, v2c / SNMP Trap UNI-NMS monitoring PLANET Smart Discovery Utility</td> </tr> <tr> <td class="align-middle">IP Version</td> <td>IPv4 and IPv6</td> </tr> <tr> <td class="align-middle">Operation Mode</td> <td>TCP Server TCP Client UDP Client Virtual COM RFC2217 Telnet Server Pair Connection – Remote (Slave) Pair Connection – Local (Master) Modbus converter server / client</td> </tr> <tr> <td class="align-middle">Virtual COM Utility Platform Supports</td> <td>Windows-based only: Windows XP Windows Server 2003 Windows 7 Windows Server 2008 Windows 8 (Must install the latest version of WinPcap) Windows Server 2012 (Must install the latest version of WinPcap) Windows 10</td> </tr> <tr> <td class="align-middle">Security</td> <td>Allows maximum 4 accessible IP address hosts/ranges</td> </tr> <tr> <td class="align-middle">SNMP MIBs</td> <td>RFC1213 MIB-II RFC1317 RS232-like MIB</td> </tr> </tbody> <thead> <tr> <th colspan="2">Standards Conformances</th> </tr> </thead> <tbody> <tr> <td class="align-middle">Regulatory Compliance</td> <td>FCC Part 15 Class A, CE Certification Class A RoHS</td> </tr> <tr> <td class="align-middle">Stability Testing</td> <td>IEC60068-2-32 (Free fall) IEC60068-2-27 (Shock) IEC60068-2-6 (Vibration)</td> </tr> <tr> <td class="align-middle">Standards</td> <td>IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-FX RFC 768 UDP RFC 793 TFTP RFC 791 IP RFC 792 ICMP RFC 854 Telnet RFC 958 NTP RFC 1591 DNS (client only) RFC 1908 SNMPv2c RFC 2068 HTTP RFC 2131 DHCP Client RFC 2732 Format for Literal IPv6 Addresses in URL's RFC 3315 DHCPv6 Client RFC 3513 IPv6 Addressing Architecture RFC 3596 DNSv6 RFC 4443 ICMPv6 EIA/TIA RS232/422/485</td> </tr> </tbody> <thead> <tr> <th colspan="2">Environment</th> </tr> </thead> <tbody> <tr> <td class="align-middle">Operating Temperature</td> <td>-40 ~ 75 degrees C</td> </tr> <tr> <td class="align-middle">Storage Temperature</td> <td>-40 ~ 85 degrees C</td> </tr> <tr> <td class="align-middle">Humidity</td> <td>5 ~ 95% (non-condensing)</td> </tr> </tbody> </table>
  • datasheet_0_date: 20201016
  • datasheet_0_version: 1.0
  • datasheet_0_description: ICS-2105AT / ICS-2102T / ICS-2102TS
  • datasheet_0_download_pdf: https://www.planet.com.sa/storage/products/ICS-2105AT_ICS-2102T_ICS-2102TS/C-ICS-210xT_L.pdf
  • quick_guide_0_date: 20221214
  • quick_guide_0_version: 1.2
  • quick_guide_0_description: Add ICS-2102T / ICS-2102TS.
  • quick_guide_0_download_pdf: https://www.planet.com.sa/storage/products/ICS-2105AT_ICS-2102T_ICS-2102TS/EMQ-ICS-210x_220x_v1.2.pdf
  • quick_guide_1_date: 20200407
  • quick_guide_1_version: 1.1
  • quick_guide_1_description: Release for ICS-2105AT
  • quick_guide_1_download_pdf: https://www.planet.com.sa/storage/products/ICS-2105AT_ICS-2102T_ICS-2102TS/EMQ-ICS-210x_220x_v1.1.pdf
  • users_manual_0_date: 20230421
  • users_manual_0_version: 1.2
  • users_manual_0_description: Modify contents of user manual.
  • users_manual_0_download_pdf: https://www.planet.com.sa/storage/products/ICS-2105AT_ICS-2102T_ICS-2102TS/EM-ICS-2x00T_v1.2.pdf
  • users_manual_1_date: 20200730
  • users_manual_1_version: 1.1
  • users_manual_1_description: Initial release.
  • users_manual_1_download_pdf: https://www.planet.com.sa/storage/products/ICS-2105AT_ICS-2102T_ICS-2102TS/EM-ICS-2x00T_v1.1.pdf
  • firmware_0_date: 20211022
  • firmware_0_version: 1.155b210805
  • firmware_0_description: Bug Fixed - 1. Make up the missing Modbus Converter Server / Client Mode 2. Fixed the problem that the "green" LED will unconditionally turn on when using RS422 and RS485 3. Fixed the problem that Smart Discovery cannot scan
  • firmware_0_download_pdf: https://www.planet.com.sa/storage/products/ICS-2105AT_ICS-2102T_ICS-2102TS/FW-ICS-21xT%20series_v1.155b210805.zip
  • utility_0_date: 20201211
  • utility_0_version: 2011041000_2521_1337_1111
  • utility_0_description: 1. Supports starting as service mode. 2. Supports simplified Chinese *Note:This utility is only for the ICS-110, ICS-120, ICS-115A, ICS-2100T, ICS-2102T, ICS-2102TS, ICS-2105AT, ICS-2200T, and ICS-2400T and NOT compatible with ICS-100, ICS-105A, ICS-2100, and ICS-2105A.
  • utility_0_download_pdf: https://www.planet.com.sa/storage/products/ICS-2105AT_ICS-2102T_ICS-2102TS/UT-VCOM_v2011041000_2521_1337_1111.zip
  • ec_declaration_0_date: 20231226
  • ec_declaration_0_version: 1.0
  • ec_declaration_0_description: EC Declaration.
  • ec_declaration_0_download_pdf: https://www.planet.com.sa/storage/products/ICS-2105AT_ICS-2102T_ICS-2102TS/IMG-2102TS_2102T_2105AT_2100T%2CICS-2105AT_2102T_2102TS_2100T.pdf
  • applications_tab:
  • key_features_tab:
  • specifications_tab:
  • astra-migrate-meta-layouts: set
  • rank_math_news_sitemap_robots: index
  • rank_math_robots: a:1:{i:0;s:5:"index";}
  • rank_math_internal_links_processed: 1

Industrial 1-port RS232/422/485 Serial Device Server with 1-Port 100BASE-FX SFP

» ICS-2105AT / ICS-2102T / ICS-2102TS

DateVersionDescriptionDownload
2020/16/101.0

ICS-2105AT / ICS-2102T / ICS-2102TS

Download Icon
DateVersionDescriptionDownload
2022/14/121.2

Add ICS-2102T / ICS-2102TS.

Download Icon
2020/07/041.1

Release for ICS-2105AT

Download Icon
DateVersionDescriptionDownload
2023/21/041.2

Modify contents of user manual.

Download Icon
2020/30/071.1

Initial release.

Download Icon
DateVersionDescriptionDownload
2023/26/121.0

EC Declaration.

Download Icon
DateVersionDescriptionDownload
2021/22/101.155b210805

Bug Fixed –
1. Make up the missing Modbus Converter Server / Client Mode
2. Fixed the problem that the “green” LED will unconditionally turn on when using RS422 and RS485
3. Fixed the problem that Smart Discovery cannot scan

Download Icon
DateVersionDescriptionDownload
2020/11/122011041000_2521_1337_1111

1. Supports starting as service mode.
2. Supports simplified Chinese
*Note:This utility is only for the ICS-110, ICS-120, ICS-115A, ICS-2100T, ICS-2102T, ICS-2102TS, ICS-2105AT, ICS-2200T, and ICS-2400T and NOT compatible with ICS-100, ICS-105A, ICS-2100, and ICS-2105A.

Download Icon

Ordering Information

ICS-2105AT / ICS-2102T / ICS-2102TS

Industrial 1-port RS232/422/485 Serial Device Server with 1-Port 100BASE-FX SFP

Ordering Information

ICS-2105AT

Industrial 1-port RS232/422/485 Serial Device Server with 1-Port 100BASE-FX SFP (-40~75 degrees C)

ICS-2102T

IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100FX SC, MM/2km, -40~75 degrees C)

ICS-2102TS

IP30 Industrial 1-Port RS232/RS422/RS485 Serial Device Server (1 x 100FX SC, SM/30km, -40~75 degrees C)