Product Meta

  • product_code: PWR-40-24 / PWR-60-24 / PWR-75-24
  • product_editor_4418_tab_content: <p>Ideal DC 24V Power Feeding Solution for Non-PoE Industrial Devices</p> <p>The following DC single output industrial DIN-rail power supply units are able to supply sufficient 24V power to non-PoE industrial devices, such as industrial Fast/Gigabit Ethernet switches and industrial VDSL2 converters. The model names and specifications are: </p> <ul> <li><strong>PWR-40-24 (MEAN WELL/MDR-40-24): </strong></li> 40W 24V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)</ul> <ul> <li><strong>PWR-60-24 (MEAN WELL/MDR-60-24): </strong></li> 60W 24V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)</ul> <ul> <li><strong>PWR-75-24 (MEAN WELL/NDR-75-24): </strong></li> 75W 24V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)</ul> <p><img style="display: block; margin-left: auto; margin-right: auto;" src="https://www.planet.com.sa/planet-storage/2025/01/PWR-40-24_PWR-75-24_L1.gif" alt="" width="600" height="414" /></p>
  • product_editor_4418_tab_enabled: yes
  • product_editor_4418_tab_content_changed: yes
  • product_editor_4418_tab_title: Applications
  • product_editor_4421_tab_content: <p style="box-sizing: border-box; margin-top: 0px; margin-bottom: 1rem; color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif; font-size: 16px;"><span style="box-sizing: border-box; color: #5070ab;"><span style="box-sizing: border-box; font-weight: bolder;">PWR-40-24 (MEAN WELL/MDR-40-24)</span></span></p> <ul style="box-sizing: border-box; margin: 0px;" type="disc"> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">Universal AC input / full range</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">Protection: short circuit, overload and over voltage</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">Cooling by free air convection</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">For installation on DIN rail TS-35/7.5 or 15</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">NEC class 2 / LPS compliant</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">LED indicator for power on</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">DC OK relay contact</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">No load power consumption<0.75W</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">100% full load burn-in test</span></span></li> </ul> <p style="box-sizing: border-box; margin-top: 0px; margin-bottom: 1rem; color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif; font-size: 16px;"><br style="box-sizing: border-box;" /><span style="box-sizing: border-box; color: #5070ab;"><span style="box-sizing: border-box; font-weight: bolder;">PWR-60-24 (MEAN WELL/MDR-60-24)</span></span></p> <ul style="box-sizing: border-box; margin: 0px;" type="disc"> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">Universal AC input / full range</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">Protection: short circuit, overload and over voltage</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">Cooling by free air convection</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">For installation on DIN rail TS-35/7.5 or 15</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">LED indicator for power on</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">DC OK relay contact</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">No load power consumption<0.75W</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">100% full load burn-in test</span></span></li> </ul> <p style="box-sizing: border-box; margin-top: 0px; margin-bottom: 1rem; color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif; font-size: 16px;"> </p> <p style="box-sizing: border-box; margin-top: 0px; margin-bottom: 1rem; color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif; font-size: 16px;"><span style="box-sizing: border-box; color: #5070ab;"><span style="box-sizing: border-box; font-weight: bolder;">PWR-75-24 (MEAN WELL/NDR-75-24)</span></span></p> <ul style="box-sizing: border-box; margin: 0px;" type="disc"> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">Universal AC input / full range</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">Protection: short circuit, overload, over voltage and over temperature</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">Cooling by free air convection</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">For installation on DIN rail TS-35/7.5 or 15</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">UL 508 (industrial control equipment) approved</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">EN61000-6-2 (EN50082-2) industrial immunity level</span></span></li> <li style="box-sizing: border-box;"><span style="color: #212529; font-family: 'Didact Gothic', Arial, 'Microsoft JhengHei', sans-serif;"><span style="font-size: 16px;">100% full load burn-in test</span></span></li> </ul>
  • product_editor_4421_tab_enabled: yes
  • product_editor_4421_tab_content_changed: yes
  • product_editor_4421_tab_title: Key Features
  • product_editor_4422_tab_content: <div class="table-responsive"> <table class="common_table_sky" style="width: 100%;"> <thead> <tr> <th colspan="2">PWR-40-24 (MEAN WELL/MDR-40-24)</th> </tr> </thead> <tbody> </tbody> <thead> <tr> <th colspan="2">Hardware Specifications</th> </tr> </thead> <tbody> <tr> <td class="align-middle">Dimensions (W x D x H)</td> <td>40 x 100 x 90mm</td> </tr> <tr> <td class="align-middle">Weight (kg)</td> <td>0.3kg</td> </tr> <tr> <td class="align-middle">Input Voltage</td> <td>85 ~ 264VAC ,50/60Hz 120 ~ 370V DC</td> </tr> <tr> <td class="align-middle">Power Output</td> <td>40 watts, 24V, 1.7A</td> </tr> <tr> <td class="align-middle">Temperature</td> <td><b>Operating:</b> -20~70 degrees C <b>Storage:</b> -40~85 degrees C</td> </tr> <tr> <td class="align-middle">Humidity</td> <td><b>Operating:</b> 20 ~ 90% <b>Storage:</b> 10 ~ 95% (non-condensing)</td> </tr> <tr> <td class="align-middle">Installation</td> <td>DIN Rail TS-35/7.5 or 15</td> </tr> <tr> <td class="align-middle">Safety & Function</td> <td>UL508, TUV EN60950-1 approved, NEC class 2 / LPS compliant</td> </tr> </tbody> <thead> <tr> <th colspan="2">PWR-60-24 (MEAN WELL/MDR-60-24)</th> </tr> </thead> <tbody> </tbody> <thead> <tr> <th colspan="2">Hardware Specifications</th> </tr> </thead> <tbody> <tr> <td class="align-middle">Dimensions (W x D x H)</td> <td>40 x 100 x 90mm</td> </tr> <tr> <td class="align-middle">Weight (kg)</td> <td>0.3kg</td> </tr> <tr> <td class="align-middle">Input Voltage</td> <td>85 ~ 264VAC,50/60Hz 120 ~ 370V DC</td> </tr> <tr> <td class="align-middle">Power Output</td> <td>60 watts, 24V, 2.5A</td> </tr> <tr> <td class="align-middle">Temperature</td> <td><b>Operating:</b> -20~70 degrees C <b>Storage:</b> -40~85 degrees C</td> </tr> <tr> <td class="align-middle">Humidity</td> <td><b>Operating:</b> 20 ~ 90% <b>Storage:</b> 10 ~ 95% (non-condensing)</td> </tr> <tr> <td class="align-middle">Installation</td> <td>DIN Rail TS-35/7.5 or 15</td> </tr> <tr> <td class="align-middle">Safety & Function</td> <td>UL508, TUV EN60950-1 approved</td> </tr> </tbody> <thead> <tr> <th colspan="2">PWR-75-24 (MEAN WELL/NDR-75-24)</th> </tr> </thead> <tbody> </tbody> <thead> <tr> <th colspan="2">Hardware Specifications</th> </tr> </thead> <tbody> <tr> <td class="align-middle">Dimensions (W x D x H)</td> <td>32 x 102 x 125mm</td> </tr> <tr> <td class="align-middle">Weight (kg)</td> <td>0.5kg</td> </tr> <tr> <td class="align-middle">Input Voltage</td> <td>90 ~ 264VA, 50/60Hz 127 ~ 370V DC [DC input operation possible by connecting AC/L(+), AC/N(-)]</td> </tr> <tr> <td class="align-middle">Power Output</td> <td>75 watts, 24V, 3.2A</td> </tr> <tr> <td class="align-middle">Temperature</td> <td><b>Operating:</b> -20~70 degrees C <b>Storage:</b> -40~85 degrees C</td> </tr> <tr> <td class="align-middle">Humidity</td> <td><b>Operating:</b> 20 ~ 95% <b>Storage:</b> 10 ~ 95% (non-condensing)</td> </tr> <tr> <td class="align-middle">Installation</td> <td>DIN Rail TS-35/7.5 or 15</td> </tr> <tr> <td class="align-middle">Safety & Function</td> <td>UL508, TUV EN60950-1 approved (meet EN60204-1)</td> </tr> </tbody> </table> </div>
  • product_editor_4422_tab_enabled: yes
  • product_editor_4422_tab_content_changed: yes
  • product_editor_4422_tab_title: Specifications
  • ekit_post_views_count: 501
  • product_editor_4418_tab_sticky_width: pw-content-1
  • product_editor_4418_tab_sticky_position: pw-left-stick
  • product_editor_4421_tab_sticky_width: pw-content-1
  • product_editor_4421_tab_sticky_position: pw-left-stick
  • product_editor_4422_tab_sticky_width: pw-content-1
  • product_editor_4422_tab_sticky_position: pw-left-stick
  • product_editor_4423_tab_content:
  • product_editor_4423_tab_content_changed: yes
  • product_editor_4423_tab_enabled: yes
  • product_editor_4423_tab_title: Downloads
  • product_editor_4423_tab_sticky_width: pw-content-1
  • product_editor_4423_tab_sticky_height: 1
  • product_editor_4423_tab_sticky_position: pw-left-stick
  • product_editor_4424_tab_content:
  • product_editor_4424_tab_content_changed: no
  • product_editor_4424_tab_enabled: yes
  • product_editor_4424_tab_title: Related Products
  • product_editor_4424_tab_sticky_width: pw-content-1
  • product_editor_4424_tab_sticky_height: 1
  • product_editor_4424_tab_sticky_position: pw-left-stick
  • total_sales: 0
  • accessories_table: <table class="common_table"> <thead> <tr> <th colspan="2">Ordering Information</th> </tr> </thead> <tbody> <tr> <td class="text-center align-middle"> <h3 class="h6 m-0">PWR-40-24 (MEAN WELL/MDR-40-24)</h3> </td> <td>40W 24V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)</td> </tr> <tr> <td class="text-center align-middle"> <h3 class="h6 m-0">PWR-60-24 (MEAN WELL/MDR-60-24)</h3> </td> <td>60W 24V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)</td> </tr> <tr> <td class="text-center align-middle"> <h3 class="h6 m-0">PWR-75-24 (MEAN WELL/NDR-75-24)</h3> </td> <td>75W 24V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)</td> </tr> </tbody> </table>                            
  • product_label:
  • prouduct_loop_image_transparent_bg_:
  • 6_features_images: a:3:{i:0;s:5:"15063";i:1;s:5:"15062";i:2;s:5:"15061";}
  • datasheet_0_date: 20240412
  • datasheet_0_version: 2.0
  • datasheet_0_description: PWR-40-24/PWR-60-24/PWR-75-24
  • datasheet_0_download_pdf: https://www.planet.com.sa/storage/products/PWR-40-24/C-PWR-24Vv2_L.pdf
  • datasheet: 1
  • quick_guide:
  • users_manual_0_date: 20230831
  • users_manual_0_version: 1.6
  • users_manual_0_description: Modify contents of user manual.
  • users_manual_0_download_pdf: https://www.planet.com.sa/storage/products/PWR-40-24/EM-PWR%20Series_v1.6.pdf
  • users_manual: 1
  • ec_declaration:
  • android_app:
  • driver:
  • firmware:
  • utility:
  • compatible_list:
  • site-sidebar-layout: default
  • ast-site-content-layout: default
  • site-content-style: default
  • site-sidebar-style: default
  • theme-transparent-header-meta: default
  • astra-migrate-meta-layouts: set
  • applications_tab: <p><strong>Ideal 24V DC Power Feeding Solution for Non-PoE Industrial Devices</strong></p><p>The following DC single output industrial DIN-rail power supply units are able to supply sufficient 24V power to non-PoE industrial devices, such as industrial Fast/Gigabit Ethernet switches and industrial VDSL2 converters. The model names and specifications are:  </p><ul> <li><strong>PWR-40-24 (MEAN WELL/MDR-40-24): </strong> <ul> <li>40W <strong>24V</strong> DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)</li> </ul> </li> <li><strong>PWR-60-24 (MEAN WELL/MDR-60-24):</strong>  <ul> <li>60W<strong> 24V</strong> DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)</li> </ul> </li> <li><strong>PWR-75-24 (MEAN WELL/XDR-75E-24):</strong>  <ul> <li>75W <strong>24V</strong> DC Single Output Industrial DIN-rail Power Supply (-40 ~ 70 degrees C)</li> </ul> </li> </ul><p> </p><p><img style="display: block; margin-left: auto; margin-right: auto;" src="https://www.planet.com.sa/planet-storage/2025/01/PWR-40-24_PWR-75-24_L2.gif" alt="" width="600" height="414"></p>
  • key_features_tab: <p><strong>PWR-40-24 (MEAN WELL/MDR-40-24)</strong></p><ul> <li>Universal AC input / full range</li> <li>Protection: short circuit, overload and over voltage</li> <li>Cooling by free air convection</li> <li>For installation on DIN rail TS-35/7.5 or 15</li> <li>NEC class 2 / LPS compliant</li> <li>LED indicator for power on</li> <li>DC OK relay contact</li> <li>No load power consumption<0.75W</li> <li>100% full load burn-in test</li> </ul><p> </p><p><strong>PWR-60-24 (MEAN WELL/MDR-60-24)</strong></p><ul> <li>Universal AC input / full range</li> <li>Protection: short circuit, overload and over voltage</li> <li>Cooling by free air convection</li> <li>For installation on DIN rail TS-35/7.5 or 15</li> <li>LED indicator for power on</li> <li>DC OK relay contact</li> <li>No load power consumption<0.75W</li> <li>100% full load burn-in test</li> </ul><p> </p><p><strong>PWR-75-24 (MEAN WELL/XDR-75E-24)</strong></p><ul> <li>Universal AC input / full range</li> <li>ITE 62368-1, Industrial 61558-1/-2-16, 61010 certificates</li> <li>Built-in constant current limiting circuit</li> <li>Protection: short circuit, overload, over voltage and over temperature</li> <li>Cooling by free air convection</li> <li>Operating altitude up to 5000 meters</li> <li>Built-in DC OK Relay contact</li> <li>For installation on DIN rail TS-35/7.5 or 15</li> </ul>
  • specifications_tab: <table style="width:100%;" class="common_table_sky"><thead><tr><th colspan="2">PWR-40-24 (MEAN WELL/MDR-40-24)</th></tr></thead><tbody><tr><td class="align-middle">Dimensions (W x D x H)</td><td>40 x 100 x 90mm</td></tr><tr><td class="align-middle">Weight (kg)</td><td>0.3kg</td></tr><tr><td class="align-middle">Input Voltage</td><td>85 ~ 264VAC ,50/60Hz<br /> 120 ~ 370VDC</td></tr><tr><td class="align-middle">Output Voltage Adj. Range</td><td>24-30V</td></tr><tr><td class="align-middle">Power Output</td><td>40 watts, 24V, 1.7A</td></tr><tr><td class="align-middle">Protection Overload</td><td>105-150% rated output power<br /> Protection type: constant current limiting, recovers automatically after fault condition is removed</td></tr><tr><td class="align-middle">Protection Over Voltage</td><td>31.2~36V<br /> Protection type: Shut down o/p voltage, re-power on to recover</td></tr><tr><td class="align-middle">Temperature</td><td><b>Operating:</b> -20~70 degrees C<br /> <b>Storage:</b> -40~85 degrees C</td></tr><tr><td class="align-middle">Humidity</td><td><b>Operating:</b> 20 ~ 90%<br /> <b>Storage:</b> 10 ~ 95% (non-condensing)</td></tr><tr><td class="align-middle">Installation</td><td>DIN Rail TS-35/7.5 or 15</td></tr><tr><td class="align-middle">Safety & Function</td><td>UL508, TUV EN60950-1 approved, NEC class 2 / LPS compliant</td></tr></tbody><thead><tr><th colspan="2">PWR-60-24 (MEAN WELL/MDR-60-24)</th></tr></thead><tbody><tr><td class="align-middle">Dimensions (W x D x H)</td><td>40 x 100 x 90mm</td></tr><tr><td class="align-middle">Weight (kg)</td><td>0.3kg</td></tr><tr><td class="align-middle">Input Voltage</td><td>85 ~ 264VAC,50/60Hz<br /> 120 ~ 370VDC</td></tr><tr><td class="align-middle">Output Voltage Adj. Range</td><td>24-30V</td></tr><tr><td class="align-middle">Power Output</td><td>60 watts, 24V, 2.5A</td></tr><tr><td class="align-middle">Protection Overload</td><td>105-150% rated output power<br /> Protection type: constant current limiting, recovers automatically after fault condition is removed</td></tr><tr><td class="align-middle">Protection Over Voltage</td><td>31.2~36V<br /> Protection type: Shut down o/p voltage, re-power on to recover</td></tr><tr><td class="align-middle">Temperature</td><td><b>Operating:</b> -20~70 degrees C<br /> <b>Storage:</b> -40~85 degrees C</td></tr><tr><td class="align-middle">Humidity</td><td><b>Operating:</b> 20 ~ 90%<br /> <b>Storage:</b> 10 ~ 95% (non-condensing)</td></tr><tr><td class="align-middle">Installation</td><td>DIN Rail TS-35/7.5 or 15</td></tr><tr><td class="align-middle">Safety & Function</td><td>UL508, TUV EN60950-1 approved</td></tr></tbody><thead><tr><th colspan="2">PWR-75-24 (MEAN WELL/XDR-75E-24)</th></tr></thead><tbody><tr><td class="align-middle">Hardware Version</td><td>3</td></tr><tr><td class="align-middle">Dimensions (W x D x H)</td><td>30 x 116 x 125mm</td></tr><tr><td class="align-middle">Weight (kg)</td><td>0.4kg</td></tr><tr><td class="align-middle">Input Voltage</td><td>85 ~ 264VAC, 50/60Hz<br /> 127 ~ 370VDC <br /> [DC input operation possible by connecting AC/L(+), AC/N(-)</td></tr><tr><td class="align-middle">Output Voltage Adj. Range</td><td>24-29V</td></tr><tr><td class="align-middle">Power Output</td><td>75 watts, 24V, 3.2A</td></tr><tr><td class="align-middle">Protection Overload</td><td>105-130% rated output power, constant current limiting without shutdown, recovers automatically after fault condition is removed</td></tr><tr><td class="align-middle">Protection Over Voltage</td><td>30~34V<br /> Protection type: Shut down o/p voltage, re-power on to recover</td></tr><tr><td class="align-middle">Protection Over Temperature</td><td>Protection type: Hiccup mode, recovers automatically after fault condition is removed</td></tr><tr><td class="align-middle">Temperature</td><td><b>Operating:</b> -40~70 degrees C<br /> <b>Storage:</b> -40~85 degrees C</td></tr><tr><td class="align-middle">Humidity</td><td><b>Operating:</b> 20 ~ 95% (non-condensing)<br /> <b>Storage:</b> 10 ~ 95% (non-condensing)</td></tr><tr><td class="align-middle">Installation</td><td>DIN Rail TS-35/7.5 or 15</td></tr><tr><td class="align-middle">Safety & Function</td><td>UL61010: TUV BS EN/EN62368-1, BS EN/EN61558-1/-2-16, BS EN/EN61010; CB IEC62368-1, IEC61558-1 IEC61010: RCM AS/NZS 62368-1, AS/NZS 61558-1/-2-16, BSMI CNS15598 -1, CCC GB4943.1,<br /> EAC TPTC004 approved: KC KC62368-1 and BIS IS13252 (Part 1):2010 certified</td></tr></tbody><thead><tr><th colspan="2">Remark</th></tr></thead><tbody></tbody></table>
  • rank_math_news_sitemap_robots: index
  • rank_math_robots: a:1:{i:0;s:5:"index";}

DC Single Output Industrial DIN-rail Power Supply Units

» PWR-40-24 / PWR-60-24 / PWR-75-24

Compact Size with more Practicability and Convenience 

PLANET has released a series of DC single output industrial DIN-rail power supply units to make sure that industrial Ethernet devices, specially designed for the harsh working environment, get DC voltage power easily.

PLANET DC single output industrial DIN rail power supply units accept universal 100-240V AC input voltage and provide 24V DC power output with various watt values. Its power supply units are designed in compact size and can be installed on DIN rail TS-35 / 7.5 or 15. It is an ideal and convenient DC power feeding solution for Industrial equipment under heavy Industrial environments.

 

Stable Performance under Difficult Environments

PLANET DC single output industrial DIN-rail power supply units come with such protection features as short circuit, overload, over voltage and over temperature for the stable operation of industrial Ethernet equipment. It uses the free air convection cooling system to prevent operating temperature from rising. Being able to operate under the temperature range from -20 to 70 degrees C (maximum), the DC single output industrial DIN-rail power supply units can be placed in almost any difficult environments. 

Ideal 24V DC Power Feeding Solution for Non-PoE Industrial Devices

The following DC single output industrial DIN-rail power supply units are able to supply sufficient 24V power to non-PoE industrial devices, such as industrial Fast/Gigabit Ethernet switches and industrial VDSL2 converters. The model names and specifications are: 

  • PWR-40-24 (MEAN WELL/MDR-40-24): 
    • 40W 24V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)
  • PWR-60-24 (MEAN WELL/MDR-60-24): 
    • 60W 24V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)
  • PWR-75-24 (MEAN WELL/XDR-75E-24): 
    • 75W 24V DC Single Output Industrial DIN-rail Power Supply (-40 ~ 70 degrees C)

 

PWR-40-24 (MEAN WELL/MDR-40-24)

  • Universal AC input / full range
  • Protection: short circuit, overload and over voltage
  • Cooling by free air convection
  • For installation on DIN rail TS-35/7.5 or 15
  • NEC class 2 / LPS compliant
  • LED indicator for power on
  • DC OK relay contact
  • No load power consumption<0.75W
  • 100% full load burn-in test

 

PWR-60-24 (MEAN WELL/MDR-60-24)

  • Universal AC input / full range
  • Protection: short circuit, overload and over voltage
  • Cooling by free air convection
  • For installation on DIN rail TS-35/7.5 or 15
  • LED indicator for power on
  • DC OK relay contact
  • No load power consumption<0.75W
  • 100% full load burn-in test

 

PWR-75-24 (MEAN WELL/XDR-75E-24)

  • Universal AC input / full range
  • ITE 62368-1, Industrial 61558-1/-2-16, 61010 certificates
  • Built-in constant current limiting circuit
  • Protection: short circuit, overload, over voltage and over temperature
  • Cooling by free air convection
  • Operating altitude up to 5000 meters
  • Built-in DC OK Relay contact
  • For installation on DIN rail TS-35/7.5 or 15
PWR-40-24 (MEAN WELL/MDR-40-24)
Dimensions (W x D x H)40 x 100 x 90mm
Weight (kg)0.3kg
Input Voltage85 ~ 264VAC ,50/60Hz
120 ~ 370VDC
Output Voltage Adj. Range24-30V
Power Output40 watts, 24V, 1.7A
Protection Overload105-150% rated output power
Protection type: constant current limiting, recovers automatically after fault condition is removed
Protection Over Voltage31.2~36V
Protection type: Shut down o/p voltage, re-power on to recover
TemperatureOperating: -20~70 degrees C
Storage: -40~85 degrees C
HumidityOperating: 20 ~ 90%
Storage: 10 ~ 95% (non-condensing)
InstallationDIN Rail TS-35/7.5 or 15
Safety & FunctionUL508, TUV EN60950-1 approved, NEC class 2 / LPS compliant
PWR-60-24 (MEAN WELL/MDR-60-24)
Dimensions (W x D x H)40 x 100 x 90mm
Weight (kg)0.3kg
Input Voltage85 ~ 264VAC,50/60Hz
120 ~ 370VDC
Output Voltage Adj. Range24-30V
Power Output60 watts, 24V, 2.5A
Protection Overload105-150% rated output power
Protection type: constant current limiting, recovers automatically after fault condition is removed
Protection Over Voltage31.2~36V
Protection type: Shut down o/p voltage, re-power on to recover
TemperatureOperating: -20~70 degrees C
Storage: -40~85 degrees C
HumidityOperating: 20 ~ 90%
Storage: 10 ~ 95% (non-condensing)
InstallationDIN Rail TS-35/7.5 or 15
Safety & FunctionUL508, TUV EN60950-1 approved
PWR-75-24 (MEAN WELL/XDR-75E-24)
Hardware Version3
Dimensions (W x D x H)30 x 116 x 125mm
Weight (kg)0.4kg
Input Voltage85 ~ 264VAC, 50/60Hz
127 ~ 370VDC
[DC input operation possible by connecting AC/L(+), AC/N(-)
Output Voltage Adj. Range24-29V
Power Output75 watts, 24V, 3.2A
Protection Overload105-130% rated output power, constant current limiting without shutdown, recovers automatically after fault condition is removed
Protection Over Voltage30~34V
Protection type: Shut down o/p voltage, re-power on to recover
Protection Over TemperatureProtection type: Hiccup mode, recovers automatically after fault condition is removed
TemperatureOperating: -40~70 degrees C
Storage: -40~85 degrees C
HumidityOperating: 20 ~ 95% (non-condensing)
Storage: 10 ~ 95% (non-condensing)
InstallationDIN Rail TS-35/7.5 or 15
Safety & FunctionUL61010: TUV BS EN/EN62368-1, BS EN/EN61558-1/-2-16, BS EN/EN61010; CB IEC62368-1, IEC61558-1 IEC61010: RCM AS/NZS 62368-1, AS/NZS 61558-1/-2-16, BSMI CNS15598 -1, CCC GB4943.1,
EAC TPTC004 approved: KC KC62368-1 and BIS IS13252 (Part 1):2010 certified
Remark
DateVersionDescriptionDownload
2024/12/042.0

PWR-40-24/PWR-60-24/PWR-75-24

Download Icon
DateVersionDescriptionDownload
2023/31/081.6

Modify contents of user manual.

Download Icon

Ordering Information

PWR-40-24 / PWR-60-24 / PWR-75-24

DC Single Output Industrial DIN-rail Power Supply Units

Ordering Information

PWR-40-24 (MEAN WELL/MDR-40-24)

40W 24V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)

PWR-60-24 (MEAN WELL/MDR-60-24)

60W 24V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)

PWR-75-24 (MEAN WELL/NDR-75-24)

75W 24V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)
                           