Product Meta

  • rank_math_seo_score: 19
  • total_sales: 0
  • datasheet_0_date: 20260817
  • datasheet_0_version: v1.0
  • datasheet_0_description: PLANET Outdoor Enclosures-3
  • datasheet_0_download_pdf: https://www.planet.com.sa/storage/products/Outdoor%20Enclosures-3/PLANET%20Outdoor%20Enclosures-3.pdf
  • datasheet: 1
  • quick_guide:
  • users_manual:
  • ec_declaration:
  • android_app:
  • driver:
  • firmware:
  • utility:
  • compatible_list:
  • accessories_table:
  • product_label:
  • product_code: PLANET Outdoor Wall-Mount Steel Enclosure
  • applications_tab: <p><strong>Outdoor, Industrial and Smart City Installations</strong></p> <p>PLANET Outdoor Wall-Mount Steel Enclosures protect network, power and control equipment wherever it has to be installed outside the comfort of a server room:</p> <div style="display:flex;flex-wrap:wrap;justify-content:center;margin:0 -9px 26px -9px;"><div style="flex:0 0 33.333%;max-width:33.333%;box-sizing:border-box;padding:9px;text-align:center;"><div style="border:1px solid #dfe6f1;background:#fff;padding:10px 10px 12px;height:100%;"><img src="https://www.planet.com.sa/wp-content/uploads/2026/08/app-01-outdoor-network-telecom-cabinet.jpg" alt="Outdoor Network and Telecom Cabinets" style="display:block;width:100%;height:auto;margin:0 auto 8px;" /><span style="display:block;font-size:15px;line-height:1.35;font-weight:600;color:#28527a;">Outdoor Network & Telecom Cabinets</span></div></div><div style="flex:0 0 33.333%;max-width:33.333%;box-sizing:border-box;padding:9px;text-align:center;"><div style="border:1px solid #dfe6f1;background:#fff;padding:10px 10px 12px;height:100%;"><img src="https://www.planet.com.sa/wp-content/uploads/2026/08/app-02-smart-city-street-cabinet.jpg" alt="Smart City Street Cabinets and Traffic Control" style="display:block;width:100%;height:auto;margin:0 auto 8px;" /><span style="display:block;font-size:15px;line-height:1.35;font-weight:600;color:#28527a;">Smart City Street Cabinets & Traffic Control</span></div></div><div style="flex:0 0 33.333%;max-width:33.333%;box-sizing:border-box;padding:9px;text-align:center;"><div style="border:1px solid #dfe6f1;background:#fff;padding:10px 10px 12px;height:100%;"><img src="https://www.planet.com.sa/wp-content/uploads/2026/08/app-03-cctv-surveillance-stainless-enclosure.jpg" alt="CCTV and IP Surveillance Infrastructure" style="display:block;width:100%;height:auto;margin:0 auto 8px;" /><span style="display:block;font-size:15px;line-height:1.35;font-weight:600;color:#28527a;">CCTV & IP Surveillance Infrastructure</span></div></div><div style="flex:0 0 33.333%;max-width:33.333%;box-sizing:border-box;padding:9px;text-align:center;"><div style="border:1px solid #dfe6f1;background:#fff;padding:10px 10px 12px;height:100%;"><img src="https://www.planet.com.sa/wp-content/uploads/2026/08/app-04-electrical-distribution-panel.jpg" alt="Electrical Distribution and Protection Panels" style="display:block;width:100%;height:auto;margin:0 auto 8px;" /><span style="display:block;font-size:15px;line-height:1.35;font-weight:600;color:#28527a;">Electrical Distribution & Protection Panels</span></div></div><div style="flex:0 0 33.333%;max-width:33.333%;box-sizing:border-box;padding:9px;text-align:center;"><div style="border:1px solid #dfe6f1;background:#fff;padding:10px 10px 12px;height:100%;"><img src="https://www.planet.com.sa/wp-content/uploads/2026/08/app-05-industrial-automation-control-panel.jpg" alt="Industrial Automation Control Panels" style="display:block;width:100%;height:auto;margin:0 auto 8px;" /><span style="display:block;font-size:15px;line-height:1.35;font-weight:600;color:#28527a;">Industrial Automation Control Panels</span></div></div><div style="flex:0 0 33.333%;max-width:33.333%;box-sizing:border-box;padding:9px;text-align:center;"><div style="border:1px solid #dfe6f1;background:#fff;padding:10px 10px 12px;height:100%;"><img src="https://www.planet.com.sa/wp-content/uploads/2026/08/app-06-ups-battery-active-cooling.jpg" alt="Power Supply and UPS Battery Housing" style="display:block;width:100%;height:auto;margin:0 auto 8px;" /><span style="display:block;font-size:15px;line-height:1.35;font-weight:600;color:#28527a;">Power Supply & UPS Battery Housing</span></div></div></div> <ul> <li>Outdoor network and telecommunication cabinets</li> <li>CCTV and IP surveillance infrastructure enclosures</li> <li>Smart city street cabinets and traffic control systems</li> <li>Industrial automation control panels</li> <li>Electrical distribution and protection panels</li> <li>IoT and LoRaWAN node enclosures</li> <li>Power supply and UPS battery housing</li> <li>Remote outdoor communication nodes</li> </ul>
  • key_features_tab: <p><strong>Construction & Finish</strong></p> <ul> <li>Steel structure with electrostatic powder coating</li> <li>Galvanized sheet-steel body and door</li> <li>Available in Standard Grey (RAL 7035), Black, Orange (RAL 2004), Red (RAL 3020) or brushed Stainless Steel AISI 304 / 316L (suffix -SS)</li> <li>Custom RAL colour finishes available as an option</li> <li>Optional anti-corrosion coating (C5) for harsh environments</li> <li>Includes galvanized steel mounting plate (chassis)</li> <li>IP65 dust and splash protection, IK10 impact resistance (IP66 on stainless steel versions)</li> </ul> <p><strong>Security & Access</strong></p> <ul> <li>Universal lock system with tamper-resistant key-lock mechanism</li> <li>Up to 3 locking points on larger models for enhanced security</li> <li>Optional transparent door for visual status monitoring</li> <li>Robust continuous hinge system on all models</li> <li>Two-door design available on larger formats, with anti-vandal lock and 300mm plinths</li> </ul> <p><strong>Thermal Management</strong></p> <ul> <li>Passive ventilation louvers (side-mounted) for natural airflow</li> <li>Dual airflow architecture: cool air intake through the upper fan, hot air exhaust through the lower louver</li> <li>Active cooling: fan + filter option for heat-sensitive equipment</li> <li>Ventilation kit with filters, resistance heating and thermostat for smart ventilation control</li> <li>FD-100W semiconductor TEC air conditioner for sealed, closed-loop internal cooling</li> <li>Optional AC unit integration for extreme environments</li> <li>Thermal analysis available upon request</li> </ul> <p><strong>Mounting Options</strong></p> <ul> <li>Fully wall-mountable (wall mounting kit included)</li> <li>Pole mounting brackets available for outdoor installations</li> <li>Suitable for pole, wall or surface mounting in harsh conditions</li> <li>Bottom cable entry with gland plate for IP-rated sealing (gland size varies by model)</li> </ul> <p><strong>Accessories</strong></p> <ul> <li>Rain canopy and protection hood against rain, dust and direct sunlight</li> <li>Heavy-duty wall mounting brackets and pole mount kit</li> <li>Sealed cable glands for secure cable entry and strain relief</li> <li>Earthing kit</li> <li>Plinths, wall supports, roofs and custom-built solutions on request</li> </ul>
  • specifications_tab: <table class="common_table_sky"> <thead> <tr> <th colspan="2">Protection</th> </tr> </thead> <tbody> <tr> <td>Ingress Protection</td> <td>IP65 (dust and splash protection)</td> </tr> <tr> <td>Impact Resistance</td> <td>IK10</td> </tr> <tr> <td>Stainless Steel Versions</td> <td>IP66</td> </tr> <tr> <td>Optional Corrosion Protection</td> <td>C5 anti-corrosion coating</td> </tr> </tbody> <thead> <tr> <th colspan="2">Construction</th> </tr> </thead> <tbody> <tr> <td>Body Material</td> <td>Galvanized steel</td> </tr> <tr> <td>Body Thickness</td> <td>1.2mm</td> </tr> <tr> <td>Door Thickness</td> <td>1.5mm</td> </tr> <tr> <td>Mounting Plate</td> <td>Galvanized steel chassis included</td> </tr> <tr> <td>Hinges</td> <td>Robust continuous hinge, all models</td> </tr> </tbody> <thead> <tr> <th colspan="2">Finish</th> </tr> </thead> <tbody> <tr> <td>Surface Treatment</td> <td>Electrostatic powder coating, 80 – 120 micron</td> </tr> <tr> <td>Standard</td> <td>Grey (RAL 7035)</td> </tr> <tr> <td>Optional</td> <td>Black (-B), Orange RAL 2004 (-OR), Red RAL 3020 (-RD)</td> </tr> <tr> <td>Stainless Steel</td> <td>AISI 304 / 316L, brushed finish (-SS)</td> </tr> <tr> <td>Custom</td> <td>Custom RAL colours on request</td> </tr> </tbody> <thead> <tr> <th colspan="2">Security</th> </tr> </thead> <tbody> <tr> <td>Lock System</td> <td>Universal tamper-resistant key lock</td> </tr> <tr> <td>Locking Points</td> <td>1 to 3, depending on enclosure size</td> </tr> <tr> <td>Options</td> <td>Transparent door, two-door design, anti-vandal lock</td> </tr> </tbody> <thead> <tr> <th colspan="2">Mounting</th> </tr> </thead> <tbody> <tr> <td>Wall Mount</td> <td>Wall mounting kit included</td> </tr> <tr> <td>Pole Mount</td> <td>Heavy-duty pole mounting brackets available</td> </tr> </tbody> <thead> <tr> <th colspan="2">Cable Entry</th> </tr> </thead> <tbody> <tr> <td>Type</td> <td>Bottom gland plate</td> </tr> <tr> <td>Gland Plate Reference</td> <td>0 – no gland plate | A – 100mm gland | B – 216mm gland | C – 330mm gland | D – 2x 330mm gland | E – 3x gland configuration</td> </tr> </tbody> <thead> <tr> <th colspan="2">Thermal Management</th> </tr> </thead> <tbody> <tr> <td>Standard</td> <td>Passive side ventilation louvers</td> </tr> <tr> <td>Airflow</td> <td>Dual airflow: upper fan intake, lower louver exhaust</td> </tr> <tr> <td>Active Cooling</td> <td>Fan + filter kit</td> </tr> <tr> <td>Ventilation Kit</td> <td>Filters, resistance heating, thermostat</td> </tr> <tr> <td>Air Conditioning</td> <td>FD-100W semiconductor TEC air conditioner, closed-loop cooling</td> </tr> <tr> <td>Optional</td> <td>Full AC unit integration</td> </tr> </tbody> <thead> <tr> <th colspan="2">Dimensions</th> </tr> </thead> <tbody> <tr> <td>Available Sizes</td> <td>38 wall-mount sizes, 200 x 200 x 150mm to 800 x 1200 x 200mm (W x H x D)</td> </tr> <tr> <td>Model Code</td> <td>Size code + finish suffix, e.g. PL504023-B = 400W x 500H x 230D mm in Black</td> </tr> </tbody> </table> <table class="common_table_sky"> <thead> <tr> <th colspan="6">Selection Guide – Wall Mount (38 Models)</th> </tr> <tr> <td><strong>Size Code</strong></td> <td><strong>W (mm)</strong></td> <td><strong>H (mm)</strong></td> <td><strong>D (mm)</strong></td> <td><strong>Locks</strong></td> <td><strong>Gland</strong></td> </tr> </thead> <tbody> <tr> <td>PL202015</td> <td>200</td> <td>200</td> <td>150</td> <td>1</td> <td>0</td> </tr> <tr> <td>PL252515</td> <td>250</td> <td>250</td> <td>150</td> <td>1</td> <td>A</td> </tr> <tr> <td>PL302015</td> <td>200</td> <td>300</td> <td>150</td> <td>1</td> <td>A</td> </tr> <tr> <td>PL302515</td> <td>250</td> <td>300</td> <td>150</td> <td>1</td> <td>B</td> </tr> <tr> <td>PL303015</td> <td>300</td> <td>300</td> <td>150</td> <td>1</td> <td>B</td> </tr> <tr> <td>PL403015</td> <td>300</td> <td>400</td> <td>150</td> <td>1</td> <td>B</td> </tr> <tr> <td>PL304015</td> <td>400</td> <td>300</td> <td>150</td> <td>1</td> <td>B</td> </tr> <tr> <td>PL204015</td> <td>400</td> <td>200</td> <td>150</td> <td>1</td> <td>B</td> </tr> <tr> <td>PL305015</td> <td>500</td> <td>300</td> <td>150</td> <td>1</td> <td>B</td> </tr> <tr> <td>PL405015</td> <td>500</td> <td>400</td> <td>150</td> <td>1</td> <td>B</td> </tr> <tr> <td>PL505015</td> <td>500</td> <td>500</td> <td>150</td> <td>1</td> <td>B</td> </tr> <tr> <td>PL605015</td> <td>500</td> <td>600</td> <td>150</td> <td>2</td> <td>B</td> </tr> <tr> <td>PL506015</td> <td>600</td> <td>500</td> <td>150</td> <td>2</td> <td>B</td> </tr> <tr> <td>PL606015</td> <td>600</td> <td>600</td> <td>150</td> <td>2</td> <td>B</td> </tr> <tr> <td>PL253020</td> <td>300</td> <td>250</td> <td>200</td> <td>1</td> <td>B</td> </tr> <tr> <td>PL303020</td> <td>300</td> <td>300</td> <td>200</td> <td>1</td> <td>B</td> </tr> <tr> <td>PL403023</td> <td>300</td> <td>400</td> <td>230</td> <td>1</td> <td>B</td> </tr> <tr> <td>PL404023</td> <td>400</td> <td>400</td> <td>230</td> <td>1</td> <td>B</td> </tr> <tr> <td>PL504023</td> <td>400</td> <td>500</td> <td>230</td> <td>1</td> <td>C</td> </tr> <tr> <td>PL406023</td> <td>400</td> <td>600</td> <td>230</td> <td>2</td> <td>C</td> </tr> <tr> <td>PL505020</td> <td>500</td> <td>500</td> <td>200</td> <td>1</td> <td>D</td> </tr> <tr> <td>PL604025</td> <td>400</td> <td>600</td> <td>250</td> <td>2</td> <td>C</td> </tr> <tr> <td>PL605020</td> <td>500</td> <td>600</td> <td>200</td> <td>2</td> <td>D</td> </tr> <tr> <td>PL606020</td> <td>600</td> <td>600</td> <td>200</td> <td>2</td> <td>D</td> </tr> <tr> <td>PL705030</td> <td>500</td> <td>700</td> <td>300</td> <td>2</td> <td>D</td> </tr> <tr> <td>PL706020</td> <td>600</td> <td>700</td> <td>200</td> <td>2</td> <td>D</td> </tr> <tr> <td>PL806025</td> <td>600</td> <td>800</td> <td>250</td> <td>2</td> <td>D</td> </tr> <tr> <td>PL806030</td> <td>600</td> <td>800</td> <td>300</td> <td>2</td> <td>E</td> </tr> <tr> <td>PL1006020</td> <td>600</td> <td>1000</td> <td>200</td> <td>3</td> <td>D</td> </tr> <tr> <td>PL1008020</td> <td>800</td> <td>1000</td> <td>200</td> <td>3</td> <td>E</td> </tr> <tr> <td>PL1206020</td> <td>600</td> <td>1200</td> <td>200</td> <td>3</td> <td>D</td> </tr> <tr> <td>PL1208020</td> <td>800</td> <td>1200</td> <td>200</td> <td>3</td> <td>E</td> </tr> <tr> <td>PL404025</td> <td>400</td> <td>400</td> <td>250</td> <td>1</td> <td>C</td> </tr> <tr> <td>PL406025</td> <td>600</td> <td>400</td> <td>250</td> <td>1</td> <td>D</td> </tr> <tr> <td>PL504025</td> <td>400</td> <td>500</td> <td>250</td> <td>1</td> <td>C</td> </tr> <tr> <td>PL505025</td> <td>500</td> <td>500</td> <td>250</td> <td>1</td> <td>D</td> </tr> <tr> <td>PL605025</td> <td>500</td> <td>600</td> <td>250</td> <td>2</td> <td>D</td> </tr> <tr> <td>PL606025</td> <td>600</td> <td>600</td> <td>250</td> <td>2</td> <td>D</td> </tr> </tbody> </table> <p>Gland plate reference: 0 – no gland plate | A – 100mm gland | B – 216mm gland | C – 330mm gland | D – 2x 330mm gland | E – 3x gland configuration</p> <p><strong>Ordering Information</strong></p> <p>Each wall-mount enclosure is ordered with a single model code built from the size code, the finish suffix and the required cable-gland option – for example PL504023-B (500 x 400 x 230 mm, black) or PL604025-SS (600 x 400 x 250 mm, stainless steel).</p> <table class="common_table_sky"> <thead><tr><th colspan="2">Model Code Structure</th></tr></thead> <tbody> <tr><td>Prefix</td><td>PL – PLANET outdoor enclosure series</td></tr> <tr><td>Size code (6 digits)</td><td>Width / Height / Depth in centimetres, e.g. 604025 = 600 x 400 x 250 mm</td></tr> <tr><td>Finish suffix</td><td>Added after the size code – see Finish & Colour Options below</td></tr> <tr><td>Cable gland option</td><td>Gland code 0 / A / B / C / D / E as listed in the Selection Guide above</td></tr> <tr><td>Model code examples</td><td>PL403023, PL504023-B, PL604025-SS, PL806030-SS</td></tr> </tbody> <thead><tr><th colspan="2">Finish & Colour Options</th></tr></thead> <tbody> <tr><td>No suffix</td><td>Standard Pebble Grey RAL 7035, electrostatic powder coating 80–120 micron</td></tr> <tr><td>-B</td><td>Black</td></tr> <tr><td>-OR</td><td>Orange RAL 2004</td></tr> <tr><td>-RD</td><td>Red RAL 3020</td></tr> <tr><td>-SS</td><td>Stainless steel AISI 304 / 316L, brushed finish (IP66, IK10)</td></tr> <tr><td>Custom</td><td>Other RAL colours available on request</td></tr> </tbody> <thead><tr><th colspan="2">Accessories & Options Ordered Separately</th></tr></thead> <tbody> <tr><td>Mounting</td><td>Wall mounting bracket set, pole mounting kit, 300 mm plinth</td></tr> <tr><td>Weather protection</td><td>Rain canopy, protection hood</td></tr> <tr><td>Cable entry</td><td>Cable gland plates and cable glands</td></tr> <tr><td>Thermal management</td><td>Ventilation kit (fan + filter), spare filters, resistance heating, thermostat</td></tr> <tr><td>Active cooling</td><td>FD-100W semiconductor TEC air conditioner with 360° circulating convection</td></tr> <tr><td>Earthing</td><td>Earthing / bonding kit</td></tr> <tr><td>Security options</td><td>Anti-vandal lock, two-door configuration, transparent inspection door</td></tr> </tbody> </table>
  • prouduct_loop_image_transparent_bg_:
  • 6_features_images: a:6:{i:0;s:5:"42408";i:1;s:5:"42409";i:2;s:5:"42410";i:3;s:5:"42411";i:4;s:5:"42412";i:5;s:5:"42413";}
  • hide_related_products_tab: 0
  • hide_downloads_tab: 0
  • rank_math_internal_links_processed: 1
  • site-sidebar-layout: default
  • ast-site-content-layout: default
  • site-content-style: default
  • site-sidebar-style: default
  • theme-transparent-header-meta: default
  • ekit_post_views_count: 23
  • astra-migrate-meta-layouts: set

PLANET Outdoor Wall-Mount Steel Enclosure

» PLANET Outdoor Wall-Mount Steel Enclosure

High-quality steel enclosures designed to combine durability with smart, practical design to meet modern project needs. Built from robust steel, PLANET enclosures shield sensitive systems from dust, impact and harsh environments, with secure installation, easy maintenance and reliable protection for technology infrastructure across all industries.

38 Wall-Mount Sizes with a Simple Model Code

The wall-mount series covers 38 sizes, from 200 x 200 x 150mm up to 800 x 1200 x 200mm (W x H x D). The model code is built from the size code plus a finish suffix, for example PL504023-B is a 400W x 500H x 230D mm enclosure in Black, and PL604025-SS is a 400W x 600H x 250D mm enclosure in stainless steel. Every size ships with the number of locking points and the gland-plate configuration matched to its footprint, listed in full in the selection guide under Specifications.

Galvanized Steel Body with Electrostatic Powder Coating

Body and door are made of galvanized sheet steel finished with 80 to 120 micron electrostatic powder coating in standard Grey (RAL 7035). Black, Orange (RAL 2004), Red (RAL 3020) and brushed stainless steel (AISI 304 or 316L, suffix -SS) versions are available, custom RAL colours can be supplied on request, and an optional C5 anti-corrosion coating is offered for harsh environments.

IP65 Sealing and IK10 Impact Resistance

The enclosure is sealed to IP65 against dust and splashing water and rated IK10 for impact resistance, so it can be installed in exposed outdoor and public locations. Cable entry runs through a bottom gland plate that preserves the ingress protection rating, and stainless steel versions raise the rating to IP66 for the most demanding sites.

Universal Lock System for Secure Access

A universal, tamper-resistant key-lock mechanism secures the door with up to 3 locking points on larger models, and a robust continuous hinge is fitted on every enclosure. An optional transparent door allows visual status monitoring without opening the cabinet, and a galvanized steel mounting plate (chassis) is included for equipment installation.

Passive and Active Thermal Management

Side-mounted ventilation louvers provide natural airflow as standard, with a dual airflow architecture that draws cool air in through the upper fan and exhausts warm air through the lower louver. For heat-sensitive equipment there is a fan and filter kit, a ventilation kit with filters, resistance heating and thermostat, an FD-100W semiconductor TEC air conditioner for sealed closed-loop cooling, and full AC unit integration for extreme environments. Thermal analysis is available on request.

Wall or Pole Installation with a Full Accessory Range

Each enclosure is fully wall-mountable with the wall mounting kit included, and heavy-duty pole mounting brackets are available for outdoor and industrial sites. Accessories include a rain canopy and protection hood against rain, dust and direct sunlight, sealed cable glands, and earthing kits. Custom-built solutions, two-door designs and plinths can be tailored to project requirements.

Dimensional & Technical Drawings

Wall-mount enclosure general views technical drawingGeneral Views – Wall-Mount EnclosureSide, front, rear and internal views with the removable bottom gland plate. Galvanised steel body 1.2 mm, door 1.5 mm, RAL 7035 electrostatic painting 80–120 micron.
Wall-mount enclosure dimensional drawing with sectionsDimensional Drawing – Ventilated Door Model615 x 639.5 x 150 mm body with a 400 x 350 mm perforated mounting plate, 515 mm fixing centres and a 600 x 50 mm gland plate with Ø25 / Ø50 / Ø60 entries. Sections B-B and C-C shown; all dimensions in mm.

Outdoor, Industrial and Smart City Installations

PLANET Outdoor Wall-Mount Steel Enclosures protect network, power and control equipment wherever it has to be installed outside the comfort of a server room:

Outdoor Network and Telecom CabinetsOutdoor Network & Telecom Cabinets
Smart City Street Cabinets and Traffic ControlSmart City Street Cabinets & Traffic Control
CCTV and IP Surveillance InfrastructureCCTV & IP Surveillance Infrastructure
Electrical Distribution and Protection PanelsElectrical Distribution & Protection Panels
Industrial Automation Control PanelsIndustrial Automation Control Panels
Power Supply and UPS Battery HousingPower Supply & UPS Battery Housing
  • Outdoor network and telecommunication cabinets
  • CCTV and IP surveillance infrastructure enclosures
  • Smart city street cabinets and traffic control systems
  • Industrial automation control panels
  • Electrical distribution and protection panels
  • IoT and LoRaWAN node enclosures
  • Power supply and UPS battery housing
  • Remote outdoor communication nodes

Construction & Finish

  • Steel structure with electrostatic powder coating
  • Galvanized sheet-steel body and door
  • Available in Standard Grey (RAL 7035), Black, Orange (RAL 2004), Red (RAL 3020) or brushed Stainless Steel AISI 304 / 316L (suffix -SS)
  • Custom RAL colour finishes available as an option
  • Optional anti-corrosion coating (C5) for harsh environments
  • Includes galvanized steel mounting plate (chassis)
  • IP65 dust and splash protection, IK10 impact resistance (IP66 on stainless steel versions)

Security & Access

  • Universal lock system with tamper-resistant key-lock mechanism
  • Up to 3 locking points on larger models for enhanced security
  • Optional transparent door for visual status monitoring
  • Robust continuous hinge system on all models
  • Two-door design available on larger formats, with anti-vandal lock and 300mm plinths

Thermal Management

  • Passive ventilation louvers (side-mounted) for natural airflow
  • Dual airflow architecture: cool air intake through the upper fan, hot air exhaust through the lower louver
  • Active cooling: fan + filter option for heat-sensitive equipment
  • Ventilation kit with filters, resistance heating and thermostat for smart ventilation control
  • FD-100W semiconductor TEC air conditioner for sealed, closed-loop internal cooling
  • Optional AC unit integration for extreme environments
  • Thermal analysis available upon request

Mounting Options

  • Fully wall-mountable (wall mounting kit included)
  • Pole mounting brackets available for outdoor installations
  • Suitable for pole, wall or surface mounting in harsh conditions
  • Bottom cable entry with gland plate for IP-rated sealing (gland size varies by model)

Accessories

  • Rain canopy and protection hood against rain, dust and direct sunlight
  • Heavy-duty wall mounting brackets and pole mount kit
  • Sealed cable glands for secure cable entry and strain relief
  • Earthing kit
  • Plinths, wall supports, roofs and custom-built solutions on request
Protection
Ingress ProtectionIP65 (dust and splash protection)
Impact ResistanceIK10
Stainless Steel VersionsIP66
Optional Corrosion ProtectionC5 anti-corrosion coating
Construction
Body MaterialGalvanized steel
Body Thickness1.2mm
Door Thickness1.5mm
Mounting PlateGalvanized steel chassis included
HingesRobust continuous hinge, all models
Finish
Surface TreatmentElectrostatic powder coating, 80 – 120 micron
StandardGrey (RAL 7035)
OptionalBlack (-B), Orange RAL 2004 (-OR), Red RAL 3020 (-RD)
Stainless SteelAISI 304 / 316L, brushed finish (-SS)
CustomCustom RAL colours on request
Security
Lock SystemUniversal tamper-resistant key lock
Locking Points1 to 3, depending on enclosure size
OptionsTransparent door, two-door design, anti-vandal lock
Mounting
Wall MountWall mounting kit included
Pole MountHeavy-duty pole mounting brackets available
Cable Entry
TypeBottom gland plate
Gland Plate Reference0 – no gland plate | A – 100mm gland | B – 216mm gland | C – 330mm gland | D – 2x 330mm gland | E – 3x gland configuration
Thermal Management
StandardPassive side ventilation louvers
AirflowDual airflow: upper fan intake, lower louver exhaust
Active CoolingFan + filter kit
Ventilation KitFilters, resistance heating, thermostat
Air ConditioningFD-100W semiconductor TEC air conditioner, closed-loop cooling
OptionalFull AC unit integration
Dimensions
Available Sizes38 wall-mount sizes, 200 x 200 x 150mm to 800 x 1200 x 200mm (W x H x D)
Model CodeSize code + finish suffix, e.g. PL504023-B = 400W x 500H x 230D mm in Black
Selection Guide – Wall Mount (38 Models)
Size CodeW (mm)H (mm)D (mm)LocksGland
PL20201520020015010
PL2525152502501501A
PL3020152003001501A
PL3025152503001501B
PL3030153003001501B
PL4030153004001501B
PL3040154003001501B
PL2040154002001501B
PL3050155003001501B
PL4050155004001501B
PL5050155005001501B
PL6050155006001502B
PL5060156005001502B
PL6060156006001502B
PL2530203002502001B
PL3030203003002001B
PL4030233004002301B
PL4040234004002301B
PL5040234005002301C
PL4060234006002302C
PL5050205005002001D
PL6040254006002502C
PL6050205006002002D
PL6060206006002002D
PL7050305007003002D
PL7060206007002002D
PL8060256008002502D
PL8060306008003002E
PL100602060010002003D
PL100802080010002003E
PL120602060012002003D
PL120802080012002003E
PL4040254004002501C
PL4060256004002501D
PL5040254005002501C
PL5050255005002501D
PL6050255006002502D
PL6060256006002502D

Gland plate reference: 0 – no gland plate | A – 100mm gland | B – 216mm gland | C – 330mm gland | D – 2x 330mm gland | E – 3x gland configuration

Ordering Information

Each wall-mount enclosure is ordered with a single model code built from the size code, the finish suffix and the required cable-gland option – for example PL504023-B (500 x 400 x 230 mm, black) or PL604025-SS (600 x 400 x 250 mm, stainless steel).

Model Code Structure
PrefixPL – PLANET outdoor enclosure series
Size code (6 digits)Width / Height / Depth in centimetres, e.g. 604025 = 600 x 400 x 250 mm
Finish suffixAdded after the size code – see Finish & Colour Options below
Cable gland optionGland code 0 / A / B / C / D / E as listed in the Selection Guide above
Model code examplesPL403023, PL504023-B, PL604025-SS, PL806030-SS
Finish & Colour Options
No suffixStandard Pebble Grey RAL 7035, electrostatic powder coating 80–120 micron
-BBlack
-OROrange RAL 2004
-RDRed RAL 3020
-SSStainless steel AISI 304 / 316L, brushed finish (IP66, IK10)
CustomOther RAL colours available on request
Accessories & Options Ordered Separately
MountingWall mounting bracket set, pole mounting kit, 300 mm plinth
Weather protectionRain canopy, protection hood
Cable entryCable gland plates and cable glands
Thermal managementVentilation kit (fan + filter), spare filters, resistance heating, thermostat
Active coolingFD-100W semiconductor TEC air conditioner with 360° circulating convection
EarthingEarthing / bonding kit
Security optionsAnti-vandal lock, two-door configuration, transparent inspection door
DateVersionDescriptionDownload
2026/17/08v1.0

PLANET Outdoor Enclosures-3

Download Icon

Ordering Information

PLANET Outdoor Wall-Mount Steel Enclosure

PLANET Outdoor Wall-Mount Steel Enclosure

Join Our Newsletter

Get the latest news, offers and updates from PLANET Technology straight to your inbox.

We respect your privacy. Unsubscribe anytime.

Subscribe to PLANET e Newsletter

Receive the latest product information and company news!