  • رمز المنتج: IGS-4215-4P4T2S
  • product_editor_4418_tab_content: <p><strong>ITU-T G.8032 ERPS Makes Data Transmission Uninterrupted </strong></p> <p>The IGS-4215-4P4T2S features strong rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates <strong>ITU-T G.8032 ERPS (تبديل حماية حلقة الإيثرنت)</strong> technology into customer’s automation network to enhance system reliability and uptime. Applying the IEEE 802.3at Power over Ethernet standard, the IGS-4215-4P4T2S can directly connect with any IEEE 802.3at end-nodes like PTZ (Pan, Tilt & Zoom) network cameras and speed dome cameras. The IGS-4215-4P4T2S can easily help system integrators with the available network infrastructure to build wireless AP, IP camera and VoIP systems where power can be centrally-controlled.</p> <p> </p> <p> </p> <p><img style="display: block; margin-left: auto; margin-right: auto;" src="https://www.planet.com.sa/wp-content/uploads/2025/01/Common_Industrial-switch-ERPS_-None-PoE.png" alt="" width="700" height="440" /></p> <p><strong>Industrial-grade PoE+ Switch for Building Automation and Security</strong></p> <p>Suitable for buildings where security is strictly to be enforced, the IGS-4215-4P4T2S, with 4 802.3at PoE+, in-line power interfaces, can easily build a power centrally controlled for an IP phone system, IP surveillance system, and wireless AP group in the harsh Industrial environment. For instance, 4 PoE IP cameras or PoE wireless APs can be easily installed for surveillance demands or a wireless roaming environment in the industrial area can be built. Without the power-socket limitation, the IGS-4215-4P4T2S makes the installation of IP cameras or wireless APs easier and more efficient.</p> <p> </p> <p><img style="display: block; margin-left: auto; margin-right: auto;" src="https://www.planet.com.sa/wp-content/uploads/2025/01/IGS-4215-4P4T2Sv2-4.png" alt="" width="700" height="456" /></p> <p> </p> <p><strong>حل تكامل مثالي لكاميرات IP PoE وأنظمة NVR</strong></p> <p>The IGS-4215-4P4T2S provides 4 10/100/1000BASE-T 802.3at PoE+ ports which can offer sufficient PoE power to 4 PoE IP cameras at the same time. In addition, with the two 100/1000BASE-X SFP interfaces, the IGS-4215-4P4T2S can connect to a core fiber switch and send video streams to an NVR and monitoring center. Through the high-performance switch architecture, the IGS-4215-4P4T2S facilitates the recorded video files from the 4 PoE+ IP cameras to be saved in the NVR systems. Furthermore, the NVR systems can be controlled and monitored in both the local LAN and the remote site via Internet. The IGS-4215-4P4T2S undoubtedly brings an ideal secure surveillance system at a lower total cost.</p> <p> </p> <p><img style="display: block; margin-left: auto; margin-right: auto;" src="https://www.planet.com.sa/wp-content/uploads/2025/01/IGS-4215-8P2T2Sv2-3.png" alt="" width="700" height="493" /></p>
  • product_editor_4418_tab_enabled: نعم
  • product_editor_4418_tab_content_changed: نعم
  • product_editor_4418_tab_title: التطبيقات
  • product_editor_4421_tab_content: <strong>منفذ فعلي</strong> <ul> <li><strong>Eight 10/100/1000BASE-T</strong> Gigabit Ethernet RJ45 ports (Ports 1 to 8)</li> <li><strong>Four</strong> منافذ مع<strong> IEEE 802.3at/af PoE+</strong> Injector function (Ports 1 to 4)</li> <li><strong>Two</strong> <strong>100/1000BASE-X SFP</strong> slots for SFP type auto detection (Ports 9 to 10)</li> <li>واجهة وحدة تحكم RJ45 واحدة للإدارة والإعداد الأساسيين</li> </ul>   <strong>الطاقة عبر الإيثرنت</strong> <ul> <li>يتوافق مع معيار IEEE 802.3at Power over Ethernet Plus، وPSE الطرفي</li> <li>متوافق مع الإصدارات السابقة من معيار IEEE 802.3af لتزويد الطاقة عبر الإيثرنت</li> <li>يدعم ما يصل إلى 4 منافذ من أجهزة IEEE 802.3af/802.3at</li> <li>144-watt PoE budget</li> <li>يدعم طاقة PoE تصل إلى 36 واط لكل منفذ PoE</li> <li>الكشف التلقائي عن الأجهزة التي تعمل بالطاقة (PD)</li> <li>تمنع حماية الدائرة تداخل الطاقة بين المنافذ</li> <li>تغذية الطاقة عن بعد لمسافة تصل إلى 100 متر في الوضع القياسي و250 متر في وضع التمديد</li> <li>إدارة نقاط التزويد بالطاقة (PoE) <ul> <li>التحكم الكامل في ميزانية طاقة PoE</li> <li>تفعيل/تعطيل وظيفة PoE لكل منفذ</li> <li>أولوية تزويد منفذ PoE بالطاقة</li> <li>تحديد الطاقة لكل منفذ PoE</li> <li>تصنيف مرض باركنسون</li> </ul> </li> <li>ميزات PoE الذكية <ul> <li>فحص حالة PD</li> <li>جدول PoE</li> </ul> </li> </ul>   <strong>علبة صناعية وتركيب</strong> <ul> <li>علبة ألومنيوم IP30</li> <li>تصميم للتركيب على سكة DIN أو على الحائط</li> <li>48~54 فولت تيار مستمر، طاقة احتياطية مع حماية من عكس القطبية</li> <li>يدعم حماية من التفريغ الكهروستاتيكي عبر الإيثرنت بجهد 6000 فولت تيار مستمر</li> <li>درجة حرارة التشغيل من -40 إلى 75 درجة مئوية</li> </ul>   <strong>التبديل</strong> <ul> <li>Hardware-based 10/100Mbps (half/full duplex), 1000Mbps (full duplex), auto-negotiation and uto MDI/MDI-X</li> <li>التحكم في التدفق وفقًا لمعيار IEEE 802.3x للتشغيل ثنائي الاتجاه الكامل، والتحكم في الضغط الخلفي للتشغيل ثنائي الاتجاه الجزئي</li> <li>حجم جدول عناوين MAC 8K</li> <li>إطار جامبو 10K</li> <li>التعلم التلقائي للعناوين وتقادم العناوين</li> </ul>   <strong>ميزات الطبقة الثانية</strong> <ul> <li>يدعم<strong> شبكة VLAN</strong> <ul> <li>شبكة VLAN الموسومة IEEE 802.1Q</li> <li>دعم ربط الموفر (VLAN Q-in-Q، IEEE 802.1ad)</li> <li>بروتوكول VLAN</li> <li>شبكة VLAN الصوتية</li> <li>شبكة VLAN خاصة (منفذ محمي)</li> <li>شبكة VLAN للإدارة</li> <li>GVRP</li> </ul> </li> <li>يدعم <strong>بروتوكول الشجرة الممتدة</strong> <ul> <li>بروتوكول الشجرة الممتدة (STP)</li> <li>بروتوكول الشجرة الممتدة السريعة (RSTP)</li> <li>بروتوكول الشجرة الممتدة المتعددة (MSTP)</li> <li>حماية بروتوكول الشجرة الممتدة (STP BPDU Guard)، وتصفية بروتوكول الشجرة الممتدة (BPDU Filtering)، وإعادة توجيه بروتوكول الشجرة الممتدة (BPDU Forwarding)</li> </ul> </li> <li>يدعم <strong>تجميع الروابط</strong> <ul> <li>بروتوكول التحكم في تجميع الروابط IEEE 802.3ad (LACP)</li> <li>قناة إيثرنت سيسكو (جذع ثابت)</li> <li>Supports 5 groups with 8 ports per trunk</li> </ul> </li> <li>يوفر خاصية النسخ المتطابق للمنفذ (من متعدد إلى واحد)</li> <li>حماية من الحلقات لتجنب حلقات البث</li> <li>يدعم تقنية ERPS (تبديل حماية حلقة الإيثرنت)</li> <li>بروتوكول اكتشاف طبقة الربط (LLDP)</li> </ul>   <strong>جودة الخدمة</strong> <ul> <li>التحكم في عرض النطاق الترددي لكل منفذ، مع تحديد معدل الإدخال/الإخراج</li> <li>تصنيف حركة المرور <ul> <li>IEEE 802.1p CoS</li> <li>أولوية TOS/DSCP/IP لحزم IPv4/IPv6</li> </ul> </li> <li>سياسات الأولوية الصارمة والتناوب المرجح (WRR) لعقد الخدمة</li> </ul>   <strong>البث المتعدد</strong> <ul> <li>يدعم بروتوكول مراقبة IGMP الإصدار 2 و 3 من بروتوكول IPv4</li> <li>يدعم بروتوكول IPv6 MLD snooping الإصدارين 1 و2</li> <li>دعم وضع استعلام IGMP</li> <li>تصفية منافذ التجسس على بروتوكول إدارة مجموعات الإنترنت (IGMP)</li> <li>تصفية منافذ التجسس MLD</li> </ul>   <strong>حماية</strong> <ul> <li>دعم مكافحة العواصف <ul> <li>Broadcast/ unknown multicast/unknown unicast</li> </ul> </li> <li>المصادقة <ul> <li>مصادقة الوصول إلى الشبكة المستندة إلى المنافذ وفقًا لمعيار IEEE 802.1X</li> <li>عميل RADIUS مدمج للتعاون مع خوادم RADIUS</li> <li>خيار DHCP رقم 82</li> <li>مصادقة RADIUS/TACACS+</li> </ul> </li> <li>قائمة التحكم بالوصول <ul> <li>قوائم التحكم بالوصول المستندة إلى بروتوكول الإنترنت IPv4/IPv6</li> <li>نظام التحكم في الوصول القائم على بروتوكول الإنترنت IPv4/IPv6</li> <li>التحكم في الوصول القائم على MAC</li> <li>ACE القائم على MAC</li> </ul> </li> <li>أمان ماك <ul> <li>عنوان MAC ثابت</li> <li>تصفية عناوين MAC</li> </ul> </li> <li>أمان المنفذ لتصفية إدخالات عنوان MAC المصدر</li> <li>مراقبة بروتوكول DHCP لتصفية رسائل DHCP غير الموثوقة</li> <li>يقوم فحص ARP الديناميكي بتجاهل حزم ARP التي تحتوي على ربط غير صالح بين عنوان MAC وعنوان IP</li> <li>يحمي نظام حماية مصدر IP من هجمات انتحال عناوين IP</li> <li>الوقاية من هجمات حجب الخدمة</li> </ul>   <strong>إدارة</strong> <ul> <li>إدارة المكدس المزدوج لـ IPv4 و IPv6</li> <li>واجهة إدارة المحول <ul> <li>إدارة تبديل الويب</li> <li>واجهة سطر الأوامر Console/Telnet</li> <li>إدارة المحولات SNMP الإصدار 1 والإصدار 2c</li> <li>الوصول الآمن عبر SSHv2 وTLSv1.2 وSNMP v3</li> </ul> </li> <li>إدارة بروتوكول إدارة الشبكة البسيط (SNMP) <ul> <li>تنبيه SNMP لحالة اتصال الواجهة (تشغيل/إيقاف)</li> <li>أربع مجموعات RMON (التاريخ، والإحصائيات، والإنذارات، والأحداث)</li> </ul> </li> <li>التحكم في مستويات امتيازات المستخدم</li> <li>عميل بروتوكول نقل الملفات البسيط (TFTP) المدمج</li> <li>تخصيص عناوين IP الثابتة و DHCP</li> <li>صيانة النظام <ul> <li>تحميل/تنزيل البرامج الثابتة عبر HTTP/TFTP</li> <li>تحميل/تنزيل الإعدادات عبر HTTP/TFTP</li> <li>صور مزدوجة</li> <li>زر إعادة ضبط الجهاز لإعادة تشغيل النظام أو إعادة ضبطه إلى إعدادات المصنع الافتراضية</li> </ul> </li> <li>بروتوكول وقت الشبكة SNTP</li> <li>تشخيص الشبكة <ul> <li>تشخيص الكابلات</li> <li>اختبار الاتصال عن بعد ICMPv6/ICMPv4</li> <li>جهاز مراقبة التشخيص الرقمي (SFP-DDM)</li> </ul> </li> <li>بروتوكول اكتشاف طبقة الربط (LLDP) وبروتوكول LLDP-MED</li> <li>تسجيل رسائل الأحداث على خادم syslog البعيد</li> <li>أداة PLANET Smart Discovery لإدارة عمليات النشر</li> <li>نظام إدارة الشبكة PLANET وCloudViewer لإدارة النشر</li> </ul>
  • product_editor_4421_tab_enabled: نعم
  • product_editor_4421_tab_content_changed: نعم
  • product_editor_4421_tab_title: الميزات الرئيسية
  • product_editor_4422_tab_content:   <div class="table-responsive"> <table class="common_table_sky" style="width: 100%;"> <thead> <tr> <th colspan="2">مواصفات الأجهزة</th> </tr> </thead> <tbody> <tr> <td class="align-middle">موانئ نحاسية</td> <td>Eight 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports (Ports 1 to 8)</td> </tr> <tr> <td class="align-middle">منفذ حقن PoE</td> <td>Four ports with 802.3af/802.3at PoE+ injector function (Ports 1 to 4)</td> </tr> <tr> <td class="align-middle">منافذ SFP</td> <td>Two 1000BASE-SX/LX/BX SFP interfaces (Ports 9 to 10) Compatible with 100BASE-FX SFP</td> </tr> <tr> <td class="align-middle">وحدة التحكم</td> <td>1 x RS232-to-RJ45 serial port (115200,8, N, 1)</td> </tr> <tr> <td class="align-middle">زر إعادة الضبط</td> <td>أقل من 5 ثوانٍ: إعادة تشغيل النظام &gt; 5 ثوانٍ: إعدادات المصنع الافتراضية</td> </tr> <tr> <td class="align-middle">موصل</td> <td>كتلة طرفية قابلة للإزالة بستة دبابيس: الدبوس 1/2 للطاقة 1؛ الدبوس 3/4 لإنذار الأعطال؛ الدبوس 5/6 للطاقة 2</td> </tr> <tr> <td class="align-middle">جهاز إنذار</td> <td>مخرج مرحل واحد لانقطاع التيار الكهربائي. قدرة تحمل تيار مرحل الإنذار: 1 أمبير عند 24 فولت تيار متردد</td> </tr> <tr> <td class="align-middle">متطلبات الطاقة</td> <td>48~54V DC, 6A (max.) (>51V DC for PoE+ output recommended)</td> </tr> <tr> <td class="align-middle">استهلاك الطاقة / تبديدها</td> <td>Max. 6.72 watts/22.91BTU (system on) Max. 156 watts/531.96BTU (Full loading)</td> </tr> <tr> <td class="align-middle">الأبعاد (العرض × العمق × الارتفاع)</td> <td>76.8 x 107.3 x 152 mm</td> </tr> <tr> <td class="align-middle">وزن</td> <td>1043g</td> </tr> <tr> <td class="align-middle">حاوية</td> <td>علبة ألومنيوم IP30</td> </tr> <tr> <td class="align-middle">تثبيت</td> <td>طقم سكة DIN وحامل جداري</td> </tr> <tr> <td class="align-middle">حماية من التفريغ الكهروستاتيكي</td> <td>تفريغ تلامسي 6 كيلو فولت تيار مستمر، تفريغ هوائي 8 كيلو فولت تيار مستمر</td> </tr> <tr> <td class="align-middle">قاد</td> <td>النظام: الطاقة 1 (<span style="color: green;">أخضر</span>) القوة 2 (<span style="color: green;">أخضر</span>) إنذار العطل (<span style="color: red;">أحمر</span>) جرس (<span style="color: green;">أخضر</span>) RO(<span style="color: green;">أخضر</span>n) Per 10/100/1000T RJ45 PoE+ Ports (Port 1~Port 4) LNK/ACT (<span style="color: green;">أخضر</span>) PoE قيد الاستخدام (<span style="color: orange;">العنبر</span>) Per 10/100/1000T RJ45Ports (Port 5~Port 8) LNK/ACT (<span style="color: green;">أخضر</span>) 1000 LNK (<span style="color: orange;">العنبر</span>) Per SFP Interface: (Port 9~Port 10) 1000 LNK/ACT (<span style="color: green;">أخضر</span>n) 100 LNK/ACT (<span style="color: orange;">العنبر</span>) PoE Usage: 30W, 60W, 90W, 120W (<span style="color: orange;">العنبر</span>)</td> </tr> </tbody> <thead> <tr> <th colspan="2">مواصفات التبديل</th> </tr> </thead> <tbody> <tr> <td class="align-middle">بنية التبديل</td> <td>التخزين والإرسال</td> </tr> <tr> <td class="align-middle">تبديل النسيج</td> <td>20Gbps/non-blocking</td> </tr> <tr> <td class="align-middle">معدل نقل البيانات في المحول 64 بايت</td> <td>14.8Mpps @64 bytes</td> </tr> <tr> <td class="align-middle">جدول عناوين MAC</td> <td>8 آلاف مشاركة</td> </tr> <tr> <td class="align-middle">مخزن البيانات المشترك</td> <td>4.1 ميغابت</td> </tr> <tr> <td class="align-middle">التحكم في التدفق</td> <td>إطار الإيقاف المؤقت IEEE 802.3x للاتصال ثنائي الاتجاه الكامل، وضغط خلفي للاتصال ثنائي الاتجاه النصفي</td> </tr> <tr> <td class="align-middle">إطار جامبو</td> <td>10 Kbytes</td> </tr> </tbody> <thead> <tr> <th colspan="2">الطاقة عبر الإيثرنت</th> </tr> </thead> <tbody> <tr> <td class="align-middle">معيار PoE</td> <td>معيار IEEE 802.3at لتزويد الطاقة عبر الإيثرنت بلس/PSE</td> </tr> <tr> <td class="align-middle">نوع مزود الطاقة PoE</td> <td>نهاية الامتداد</td> </tr> <tr> <td class="align-middle">تخصيص دبابيس الطاقة</td> <td>1/2(+), 3/6(-)</td> </tr> <tr> <td class="align-middle">مخرج طاقة PoE</td> <td>IEEE 802.3af Standard - Per port 48V~51V DC, max. 15.4 watts IEEE 802.3at Standard - Per port 51V~54V DC, max. 36 watts</td> </tr> <tr> <td class="align-middle">ميزانية طاقة PoE</td> <td>Maximum 144W (depending on power input)</td> </tr> <tr> <td class="align-middle">الحد الأقصى لعدد مديري التطوير المهني من الفئة الثانية</td> <td>4</td> </tr> <tr> <td class="align-middle">الحد الأقصى لعدد مديري التطوير المهني من الفئة 3</td> <td>4</td> </tr> <tr> <td class="align-middle">الحد الأقصى لعدد مديري التطوير المهني من الفئة 4</td> <td>4</td> </tr> </tbody> <thead> <tr> <th colspan="2">وظائف إدارة تقنية PoE</th> </tr> </thead> <tbody> <tr> <td class="align-middle">إدارة نقاط الطاقة عبر الإيثرنت</td> <td>فحص حالة PD، إعادة تدوير الطاقة المجدولة، جدولة PoE، مراقبة استخدام PoE، تمديد PoE</td> </tr> <tr> <td class="align-middle">وضع PoE المحسّن</td> <td>Standard/Legacy/Force</td> </tr> <tr> <td class="align-middle">الكشف المباشر عن أجهزة PoE النشطة</td> <td>نعم</td> </tr> <tr> <td class="align-middle">إعادة تدوير طاقة PoE</td> <td>نعم، جدول يومي أو جدول زمني محدد مسبقاً</td> </tr> <tr> <td class="align-middle">جدول PoE</td> <td>4 ملفات تعريف الجدول الزمني</td> </tr> <tr> <td class="align-middle">وضع تمديد PoE</td> <td>نعم، بحد أقصى يصل إلى 250 متراً</td> </tr> </tbody> <thead> <tr> <th colspan="2">وظائف الطبقة الثانية</th> </tr> </thead> <tbody> <tr> <td class="align-middle">نسخ المنفذ</td> <td>إرسال/استقبال/كلاهما، شاشة متعددة في واحد، حتى 4 جلسات</td> </tr> <tr> <td class="align-middle">شبكة VLAN</td> <td>شبكة VLAN موسومة 802.1Q، نفق Q-in-Q 802.1ad (تكديس شبكات VLAN)، شبكة VLAN الصوتية، شبكة VLAN البروتوكولية، شبكة VLAN الخاصة (منفذ محمي)، شبكة VLAN الإدارية GVRP، ما يصل إلى 256 مجموعة VLAN من أصل 4094 معرّف VLAN</td> </tr> <tr> <td class="align-middle">تجميع الروابط</td> <td>IEEE 802.3ad LACP and static trunk Supports 5 groups with 8 ports per trunk</td> </tr> <tr> <td class="align-middle">بروتوكول الشجرة الممتدة</td> <td>بروتوكول الشجرة الممتدة IEEE 802.1D (STP) بروتوكول الشجرة الممتدة السريع IEEE 802.1w (RSTP) بروتوكول الشجرة الممتدة المتعددة IEEE 802.1s (MSTP) حماية وحدة بيانات بروتوكول الشجرة الممتدة (BPDU) في بروتوكول الشجرة الممتدة، وتصفية وحدة بيانات بروتوكول الشجرة الممتدة، وإعادة توجيه وحدة بيانات بروتوكول الشجرة الممتدة</td> </tr> <tr> <td class="align-middle">التجسس على بروتوكول إدارة مجموعات الإنترنت (IGMP)</td> <td>مراقبة بروتوكول إدارة مجموعات الإنترنت IPv4 الإصدارين 2 و3، مُستعلم بروتوكول إدارة مجموعات الإنترنت، ما يصل إلى 256 مجموعة بث متعدد</td> </tr> <tr> <td class="align-middle">التجسس على MLD</td> <td>مراقبة بروتوكول MLD لبروتوكول IPv6 الإصدارين 2 و3، بما يصل إلى 256 مجموعة بث متعدد</td> </tr> <tr> <td class="align-middle">قائمة التحكم بالوصول</td> <td>قوائم التحكم بالوصول المستندة إلى بروتوكول الإنترنت (IPv4/IPv6) / قوائم التحكم بالوصول المستندة إلى عنوان MAC / قوائم التحكم بالوصول المستندة إلى بروتوكول الإنترنت (IPv4/IPv6) / قوائم التحكم بالوصول المستندة إلى عنوان MAC</td> </tr> <tr> <td class="align-middle">جودة الخدمة</td> <td>ثمانية معرّفات ربط بثمانية مستويات من قوائم الانتظار ذات الأولوية، رقم المنفذ، أولوية 802.1p، أسبقية DSCP/IP لحزم IPv4/IPv6، تصنيف حركة المرور بناءً على الأولوية الصارمة وWRR، حد معدل الدخول/الخروج، التحكم في عرض النطاق الترددي لكل منفذ</td> </tr> <tr> <td class="align-middle">جرس</td> <td>يدعم بروتوكول ERPS، ويتوافق مع معيار ITU-T G.8032 لوقت الاسترداد &lt; 450 مللي ثانية</td> </tr> </tbody> <thead> <tr> <th colspan="2">وظائف الأمان</th> </tr> </thead> <tbody> <tr> <td class="align-middle">قائمة التحكم بالوصول</td> <td>قوائم التحكم بالوصول المستندة إلى بروتوكول الإنترنت (IPv4/IPv6) وقوائم التحكم بالوصول المستندة إلى عناوين MAC. الحد الأقصى لعدد عناصر قوائم التحكم بالوصول: 256 عنصرًا.</td> </tr> <tr> <td class="align-middle">أمن الموانئ</td> <td>معيار IEEE 802.1X - مصادقة قائمة على المنفذ، عميل RADIUS مدمج للتعاون مع خادم RADIUS، مصادقة وصول المستخدم RADIUS/TACACS+</td> </tr> <tr> <td class="align-middle">أمان ماك</td> <td>ربط منفذ IP-MAC، مرشح MAC، عنوان MAC ثابت، بحد أقصى 256 مدخل MAC ثابت</td> </tr> <tr> <td class="align-middle">أمان مُعزز</td> <td>مراقبة DHCP وخيار DHCP 82، حماية STP BPDU، تصفية BPDU، إعادة توجيه BPDU، منع هجمات DoS، فحص ARP، حماية مصدر IP</td> </tr> </tbody> <thead> <tr> <th colspan="2">الوظائف الإدارية</th> </tr> </thead> <tbody> <tr> <td class="align-middle">واجهات الإدارة الأساسية</td> <td>RS232 إلى RJ45 وحدة تحكم متصفح الويب Telnet SNMP الإصدار 1، الإصدار 2c</td> </tr> <tr> <td class="align-middle">واجهات إدارة آمنة</td> <td>SSHv2، TLS v1.2، SNMP v3</td> </tr> <tr> <td class="align-middle">إدارة النظام</td> <td>Firmware upgrade by HTTP/TFTP protocol through Ethernet network Configuration upload/download through HTTP/TFTP LLDP protocol SNTP PLANET Smart Discovery Utility PLANET NMS System/CloudViewer</td> </tr> <tr> <td class="align-middle">إدارة الفعاليات</td> <td>سجل النظام عن بُعد/محلي</td> </tr> <tr> <td class="align-middle">قواعد معلومات إدارة بروتوكول إدارة الشبكة البسيط (SNMP MIBs)</td> <td>RFC 1213 MIB-II، RFC 1215 مصائد عامة، RFC 1493 MIB للجسر، RFC 2674 ملحقات MIB للجسر، RFC 2737 MIB للكيان (الإصدار 2)، RFC 2819 RMON (1، 2، 3، 9)، RFC 2863 MIB لمجموعة الواجهة، RFC 3635 MIB شبيه بشبكة إيثرنت، RFC 3621 MIB لشبكة إيثرنت الطاقة</td> </tr> </tbody> <thead> <tr> <th colspan="2">الامتثال للمعايير</th> </tr> </thead> <tbody> <tr> <td class="align-middle">الامتثال التنظيمي</td> <td>الجزء 15 من لجنة الاتصالات الفيدرالية، الفئة أ، علامة CE</td> </tr> <tr> <td class="align-middle">اختبار الثبات</td> <td>IEC 60068-2-32 (السقوط الحر) IEC 60068-2-27 (الصدمة) IEC 60068-2-6 (الاهتزاز)</td> </tr> <tr> <td class="align-middle">الامتثال للمعايير</td> <td>IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX/100BASE-FX IEEE 802.3z Gigabit SX/LX IEEE 802.3ab Gigabit 1000BASE-T IEEE 802.3x Flow Control and Back Pressure IEEE 802.3ad Port Trunk with LACP IEEE 802.1D Spanning Tree Protocol IEEE 802.1w Rapid Spanning Tree Protocol IEEE 802.1s Multiple Spanning Tree Protocol IEEE 802.1p Class of Service IEEE 802.1Q VLAN Tagging IEEE 802.1x Port Authentication Network Control IEEE 802.1ab LLDP IEEE 802.3af Power over Ethernet IEEE 802.3at Power over Ethernet Plus IEEE 802.3az for Energy-Efficient Ethernet RFC 768 UDP RFC 783 TFTP RFC 791 IP RFC 792 ICMP RFC 2068 HTTP RFC 1112 IGMP v1 RFC 2236 IGMP v2 RFC 3376 IGMP v3 RFC 2710 MLD v1 RFC 3810 MLD v2 ITU G.8032 ERPS Ring</td> </tr> </tbody> <thead> <tr> <th colspan="2">بيئة</th> </tr> </thead> <tbody> <tr> <td class="align-middle">درجة حرارة التشغيل</td> <td>-40 ~ 75 درجة مئوية</td> </tr> <tr> <td class="align-middle">درجة حرارة التخزين</td> <td>-40 ~ 85 درجة مئوية</td> </tr> <tr> <td class="align-middle">رطوبة</td> <td>5 ~ 95% (غير مكثف)</td> </tr> </tbody> </table> </div>
  • product_editor_4422_tab_enabled: نعم
  • product_editor_4422_tab_content_changed: نعم
  • product_editor_4422_tab_title: تحديد
  • عدد مشاهدات منشورات ekit: 680
  • product_editor_4418_tab_sticky_width: pw-content-1
  • product_editor_4418_tab_sticky_position: pw-left-stick
  • product_editor_4421_tab_sticky_width: pw-content-1
  • product_editor_4421_tab_sticky_position: pw-left-stick
  • product_editor_4422_tab_sticky_width: pw-content-1
  • product_editor_4422_tab_sticky_position: pw-left-stick
  • product_editor_4423_tab_content:
  • product_editor_4423_tab_content_changed: نعم
  • product_editor_4423_tab_enabled: نعم
  • product_editor_4423_tab_title: التنزيلات
  • product_editor_4423_tab_sticky_width: pw-content-1
  • product_editor_4423_tab_sticky_height: 1
  • product_editor_4423_tab_sticky_position: pw-left-stick
  • product_editor_4424_tab_content:
  • product_editor_4424_tab_content_changed: نعم
  • product_editor_4424_tab_enabled: نعم
  • product_editor_4424_tab_title: المنتجات ذات الصلة
  • product_editor_4424_tab_sticky_width: pw-content-1
  • product_editor_4424_tab_sticky_height: 1
  • product_editor_4424_tab_sticky_position: pw-left-stick
  • إجمالي المبيعات: 0
  • جدول الملحقات: <table class="common_table"> <thead> <tr> <th colspan="2">معلومات الطلب</th> </tr> </thead> <tbody> <tr> <td class="text-center align-middle" style="width:30%; padding:15px; border:1px solid #eee;"> <h3 class="h6 m-0" style="margin:0;">IGS-4215-4P4T2S</h3> </td> <td style="padding:15px; border:1px solid #eee;">Industrial 4-Port 10/100/1000T 802.3at PoE + 4-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Switch</td> </tr> </tbody> </table>
  • product_label:
  • prouduct_loop_image_transparent_bg_:
  • 6_features_images: a:6:{i:0;i:4409;i:1;i:15350;i:2;i:7472;i:3;i:7167;i:4;i:7164;i:5;i:41893;}
  • datasheet_0_date: 20231201
  • datasheet_0_version: 2.0
  • وصف ورقة البيانات 0: IGS-4215-4P4T2S
  • datasheet_0_download_pdf: https://www.planet.com.sa/storage/products/igs-4215-4p4t2s-v2/C-IGS-4215-PoE Series_L.pdf
  • ورقة البيانات: 1
  • quick_guide_0_date: 20240705
  • quick_guide_0_version: 2.2
  • quick_guide_0_description: [إصدار للأجهزة الإصدار 2.0.] تمت إضافة وظيفة PSTI.
  • quick_guide_0_download_pdf: https://www.planet.com.sa/storage/products/igs-4215-4p4t2s-v2/EMQ-IGS-4215-PoE Series_v2.2.pdf
  • quick_guide_1_date: 20230923
  • quick_guide_1_version: 2.1
  • quick_guide_1_description: Add IGS-4215-16P2T2S.
  • quick_guide_1_download_pdf: https://www.planet.com.sa/storage/products/igs-4215-4p4t2s-v2/EMQ-IGS-4215-PoE Series v2.1.pdf
  • quick_guide_2_date: 20230107
  • quick_guide_2_version: 2.0
  • وصف الدليل السريع 2: إصدار متوافق مع إصدار الجهاز 2.0.
  • quick_guide_2_download_pdf: https://www.planet.com.sa/storage/products/igs-4215-4p4t2s-v2/EMQ-IGS-4215-PoE Series v2.0.pdf
  • دليل سريع: 3
  • users_manual_0_date: 20250911
  • دليل المستخدم_الإصدار_0: 2.1
  • وصف دليل المستخدم 0: [Release for hardware version 2.0.] Modify contents of command guide.
  • users_manual_0_download_pdf: https://www.planet.com.sa/storage/products/igs-4215-4p4t2s-v2/EM-IGS-4215_801M_WGS-4215_804HPT Series Command Guide_v2.1.pdf
  • تاريخ دليل المستخدم 1: 20250116
  • دليل المستخدم_الإصدار_1: 1.5
  • وصف دليل المستخدم 1: [إصدار للأجهزة الإصدار 2.0.] تمت إضافة وظيفة PSTI.
  • users_manual_1_download_pdf: https://www.planet.com.sa/storage/products/igs-4215-4p4t2s-v2/EM-IGS-4215 PoE series_v1.5.pdf
  • دليل المستخدم 2 التاريخ: 20230428
  • دليل المستخدم_الإصدار_2: 2.0
  • وصف دليل المستخدم 2: [Command Guide] Release for hardware version 2.0.
  • دليل المستخدم 2 - تنزيل ملف PDF: https://www.planet.com.sa/storage/products/igs-4215-4p4t2s-v2/EM-IGS-4215 Series Command Guide_v2.0.pdf
  • دليل المستخدم: 4
  • ec_declaration_0_date: 20230426
  • ec_declaration_0_version: 2.0
  • ec_declaration_0_description: إصدار متوافق مع إصدار الجهاز 2.0.
  • ec_declaration_0_download_pdf: https://www.planet.com.sa/storage/products/igs-4215-4p4t2s-v2/IGS-4215-8P2T2Sv2,IGS-4215-4P4T2Sv2,IGS-4215-4P4Tv2.pdf
  • ec_declaration: 2
  • تطبيق أندرويد:
  • السائق:
  • firmware_0_date: 20251020
  • firmware_0_version: 2.305b251017
  • firmware_0_description: [Release for hardware version 2.0.] Support PLANET CloudNMS.
  • firmware_0_download_pdf: https://www.planet.com.tw/storage/products/49588/FW-IGS-4215-4P4T2S_v2.305b251017.zip
  • firmware_1_date: 20250723
  • firmware_1_version: 2.305b250717
  • firmware_1_description: [Release for hardware version 2.0.] Enhanced product security.
  • firmware_1_download_pdf: https://www.planet.com.tw/storage/products/49588/FW-IGS-4215-4P4T2S_v2.305b250717.zip
  • البرامج الثابتة: 4
  • جدوى:
  • قائمة_التوافق:
  • تخطيط الشريط الجانبي للموقع: تقصير
  • ast-site-content-layout: تقصير
  • نمط محتوى الموقع: تقصير
  • نمط الشريط الجانبي للموقع: تقصير
  • theme-transparent-header-meta: تقصير
  • astra-migrate-meta-layouts: تعيين
  • علامة تبويب التطبيقات: <p><strong>ITU-T G.8032 ERPS Makes Data Transmission Uninterrupted </strong><p>The IGS-4215-4P4T2S features strong rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates <strong>ITU-T G.8032 ERPS (تبديل حماية حلقة الإيثرنت)</strong> technology into customer’s automation network to enhance system reliability and uptime. Applying the IEEE 802.3at Power over Ethernet standard, the IGS-4215-4P4T2S can directly connect with any IEEE 802.3at end-nodes like PTZ (Pan, Tilt & Zoom) network cameras and speed dome cameras. The IGS-4215-4P4T2S can easily help system integrators with the available network infrastructure to build wireless AP, IP camera and VoIP systems where power can be centrally-controlled.</p><p> </p><p> </p><p><img style="display: block; margin-left: auto; margin-right: auto;" src="https://www.planet.com.sa/wp-content/uploads/2025/01/Common_Industrial-switch-ERPS_-None-PoE.png" alt="" width="700" height="440"></p><p><strong>Industrial-grade PoE+ Switch for Building Automation and Security</strong></p><p>Suitable for buildings where security is strictly to be enforced, the IGS-4215-4P4T2S, with 4 802.3at PoE+, in-line power interfaces, can easily build a power centrally controlled for an IP phone system, IP surveillance system, and wireless AP group in the harsh Industrial environment. For instance, 4 PoE IP cameras or PoE wireless APs can be easily installed for surveillance demands or a wireless roaming environment in the industrial area can be built. Without the power-socket limitation, the IGS-4215-4P4T2S makes the installation of IP cameras or wireless APs easier and more efficient.</p><p> </p><p><img style="display: block; margin-left: auto; margin-right: auto;" src="https://www.planet.com.sa/wp-content/uploads/2025/01/IGS-4215-4P4T2Sv2-4.png" alt="" width="700" height="456"></p><p> </p><p><strong>حل تكامل مثالي لكاميرات IP PoE وأنظمة NVR</strong></p><p>The IGS-4215-4P4T2S provides 4 10/100/1000BASE-T 802.3at PoE+ ports which can offer sufficient PoE power to 4 PoE IP cameras at the same time. In addition, with the two 100/1000BASE-X SFP interfaces, the IGS-4215-4P4T2S can connect to a core fiber switch and send video streams to an NVR and monitoring center. Through the high-performance switch architecture, the IGS-4215-4P4T2S facilitates the recorded video files from the 4 PoE+ IP cameras to be saved in the NVR systems. Furthermore, the NVR systems can be controlled and monitored in both the local LAN and the remote site via Internet. The IGS-4215-4P4T2S undoubtedly brings an ideal secure surveillance system at a lower total cost.</p><p> </p><p><img style="display: block; margin-left: auto; margin-right: auto;" src="https://www.planet.com.sa/wp-content/uploads/2025/01/IGS-4215-8P2T2Sv2-3.png" alt="" width="700" height="493"></p></p>
  • key_features_tab: <p><strong>منفذ فعلي</strong><ul> <li><strong>Eight 10/100/1000BASE-T</strong> Gigabit Ethernet RJ45 ports (Ports 1 to 8)</li> <li><strong>Four</strong> منافذ مع<strong> IEEE 802.3at/af PoE+</strong> Injector function (Ports 1 to 4)</li> <li><strong>Two</strong> <strong>100/1000BASE-X SFP</strong> slots for SFP type auto detection (Ports 9 to 10)</li> <li>واجهة وحدة تحكم RJ45 واحدة للإدارة والإعداد الأساسيين</li> </ul><p> </p><p><strong>الطاقة عبر الإيثرنت</strong></p><ul> <li>يتوافق مع معيار IEEE 802.3at Power over Ethernet Plus، وPSE الطرفي</li> <li>متوافق مع الإصدارات السابقة من معيار IEEE 802.3af لتزويد الطاقة عبر الإيثرنت</li> <li>يدعم ما يصل إلى 4 منافذ من أجهزة IEEE 802.3af/802.3at</li> <li>144-watt PoE budget</li> <li>يدعم طاقة PoE تصل إلى 36 واط لكل منفذ PoE</li> <li>الكشف التلقائي عن الأجهزة التي تعمل بالطاقة (PD)</li> <li>تمنع حماية الدائرة تداخل الطاقة بين المنافذ</li> <li>تغذية الطاقة عن بعد لمسافة تصل إلى 100 متر في الوضع القياسي و250 متر في وضع التمديد</li> <li>إدارة نقاط التزويد بالطاقة (PoE) <ul> <li>التحكم الكامل في ميزانية طاقة PoE</li> <li>تفعيل/تعطيل وظيفة PoE لكل منفذ</li> <li>أولوية تزويد منفذ PoE بالطاقة</li> <li>تحديد الطاقة لكل منفذ PoE</li> <li>تصنيف مرض باركنسون</li> </ul> </li> <li>ميزات PoE الذكية <ul> <li>فحص حالة PD</li> <li>جدول PoE</li> </ul> </li> </ul><p> </p><p><strong>علبة صناعية وتركيب</strong></p><ul> <li>علبة ألومنيوم IP30 </li> <li>تصميم للتركيب على سكة DIN أو على الحائط</li> <li>48~54 فولت تيار مستمر، طاقة احتياطية مع حماية من عكس القطبية</li> <li>يدعم حماية من التفريغ الكهروستاتيكي عبر الإيثرنت بجهد 6000 فولت تيار مستمر</li> <li>درجة حرارة التشغيل من -40 إلى 75 درجة مئوية </li> </ul><p> </p><p><strong>التبديل</strong></p><ul> <li>Hardware-based 10/100Mbps (half/full duplex), 1000Mbps (full duplex), auto-negotiation and uto MDI/MDI-X</li> <li>التحكم في التدفق وفقًا لمعيار IEEE 802.3x للتشغيل ثنائي الاتجاه الكامل، والتحكم في الضغط الخلفي للتشغيل ثنائي الاتجاه الجزئي</li> <li>حجم جدول عناوين MAC 8K</li> <li>إطار جامبو 10K</li> <li>التعلم التلقائي للعناوين وتقادم العناوين</li> </ul><p> </p><p><strong>ميزات الطبقة الثانية</strong></p><ul> <li>يدعم<strong> شبكة VLAN</strong> <ul> <li>شبكة VLAN الموسومة IEEE 802.1Q</li> <li>دعم ربط الموفر (VLAN Q-in-Q، IEEE 802.1ad)</li> <li>بروتوكول VLAN</li> <li>شبكة VLAN الصوتية</li> <li>شبكة VLAN خاصة (منفذ محمي)</li> <li>شبكة VLAN للإدارة</li> <li>GVRP</li> </ul> </li> <li>يدعم <strong>بروتوكول الشجرة الممتدة</strong> <ul> <li>بروتوكول الشجرة الممتدة (STP)</li> <li>بروتوكول الشجرة الممتدة السريعة (RSTP)</li> <li>بروتوكول الشجرة الممتدة المتعددة (MSTP)</li> <li>حماية بروتوكول الشجرة الممتدة (STP BPDU Guard)، وتصفية بروتوكول الشجرة الممتدة (BPDU Filtering)، وإعادة توجيه بروتوكول الشجرة الممتدة (BPDU Forwarding)</li> </ul> </li> <li>يدعم <strong>تجميع الروابط</strong> <ul> <li>بروتوكول التحكم في تجميع الروابط IEEE 802.3ad (LACP)</li> <li>قناة إيثرنت سيسكو (جذع ثابت)</li> <li>Supports 5 groups with 8 ports per trunk</li> </ul> </li> <li>يوفر خاصية النسخ المتطابق للمنفذ (من متعدد إلى واحد)</li> <li>حماية من الحلقات لتجنب حلقات البث</li> <li>يدعم تقنية ERPS (تبديل حماية حلقة الإيثرنت)</li> <li>بروتوكول اكتشاف طبقة الربط (LLDP) </li> </ul><p> </p><p><strong>جودة الخدمة</strong></p><ul> <li>التحكم في عرض النطاق الترددي لكل منفذ، مع تحديد معدل الإدخال/الإخراج</li> <li>تصنيف حركة المرور <ul> <li>IEEE 802.1p CoS</li> <li>أولوية TOS/DSCP/IP لحزم IPv4/IPv6</li> </ul> </li> <li>سياسات الأولوية الصارمة والتناوب المرجح (WRR) لعقد الخدمة</li> </ul><p> </p><p><strong>البث المتعدد</strong></p><ul> <li>يدعم بروتوكول مراقبة IGMP الإصدار 2 و 3 من بروتوكول IPv4</li> <li>يدعم بروتوكول IPv6 MLD snooping الإصدارين 1 و2</li> <li>دعم وضع استعلام IGMP</li> <li>تصفية منافذ التجسس على بروتوكول إدارة مجموعات الإنترنت (IGMP)</li> <li>تصفية منافذ التجسس MLD</li> </ul><p> </p><p><strong>حماية</strong></p><ul> <li>دعم مكافحة العواصف <ul> <li>Broadcast/ unknown multicast/unknown unicast</li> </ul> </li> <li>المصادقة <ul> <li>مصادقة الوصول إلى الشبكة المستندة إلى المنافذ وفقًا لمعيار IEEE 802.1X</li> <li>عميل RADIUS مدمج للتعاون مع خوادم RADIUS</li> <li>خيار DHCP رقم 82</li> <li>مصادقة RADIUS/TACACS+ </li> </ul> </li> <li>قائمة التحكم بالوصول <ul> <li>قوائم التحكم بالوصول المستندة إلى بروتوكول الإنترنت IPv4/IPv6</li> <li>نظام التحكم في الوصول القائم على بروتوكول الإنترنت IPv4/IPv6</li> <li>التحكم في الوصول القائم على MAC</li> <li>ACE القائم على MAC</li> </ul> </li> <li>أمان ماك <ul> <li>عنوان MAC ثابت</li> <li>تصفية عناوين MAC</li> </ul> </li> <li>أمان المنفذ لتصفية إدخالات عنوان MAC المصدر</li> <li>مراقبة بروتوكول DHCP لتصفية رسائل DHCP غير الموثوقة</li> <li>يقوم فحص ARP الديناميكي بتجاهل حزم ARP التي تحتوي على ربط غير صالح بين عنوان MAC وعنوان IP</li> <li>يحمي نظام حماية مصدر IP من هجمات انتحال عناوين IP</li> <li>الوقاية من هجمات حجب الخدمة</li> </ul><p> </p><p><strong>إدارة</strong></p><ul> <li>إدارة المكدس المزدوج لـ IPv4 و IPv6</li> <li>واجهة إدارة المحول <ul> <li>إدارة تبديل الويب </li> <li>واجهة سطر الأوامر Console/Telnet </li> <li>إدارة المحولات SNMP الإصدار 1 والإصدار 2c</li> <li>الوصول الآمن عبر SSHv2 وTLSv1.2 وSNMP v3</li> </ul> </li> <li>إدارة بروتوكول إدارة الشبكة البسيط (SNMP) <ul> <li>تنبيه SNMP لحالة اتصال الواجهة (تشغيل/إيقاف)</li> <li>أربع مجموعات RMON (التاريخ، والإحصائيات، والإنذارات، والأحداث) </li> </ul> </li> <li>التحكم في مستويات امتيازات المستخدم</li> <li>عميل بروتوكول نقل الملفات البسيط (TFTP) المدمج</li> <li>تخصيص عناوين IP الثابتة و DHCP</li> <li>صيانة النظام <ul> <li>تحميل/تنزيل البرامج الثابتة عبر HTTP/TFTP</li> <li>تحميل/تنزيل الإعدادات عبر HTTP/TFTP</li> <li>صور مزدوجة</li> <li>زر إعادة ضبط الجهاز لإعادة تشغيل النظام أو إعادة ضبطه إلى إعدادات المصنع الافتراضية</li> </ul> </li> <li>بروتوكول وقت الشبكة SNTP</li> <li>تشخيص الشبكة <ul> <li>تشخيص الكابلات</li> <li>اختبار الاتصال عن بعد ICMPv6/ICMPv4</li> <li>جهاز مراقبة التشخيص الرقمي (SFP-DDM)</li> </ul> </li> <li>بروتوكول اكتشاف طبقة الربط (LLDP) وبروتوكول LLDP-MED</li> <li>تسجيل رسائل الأحداث على خادم syslog البعيد</li> <li>أداة PLANET Smart Discovery لإدارة عمليات النشر</li> <li>نظام إدارة الشبكة PLANET وCloudViewer لإدارة النشر</li> </ul></p>
  • علامة تبويب المواصفات: <table style="width:100%;" class="common_table_sky"><thead><tr><th colspan="2">مواصفات الأجهزة</th></tr></thead><tbody><tr><td class="align-middle">موانئ نحاسية</td><td>Eight 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports (Ports 1 to 8)</td></tr><tr><td class="align-middle">منفذ حقن PoE</td><td>Four ports with 802.3af/802.3at PoE+ injector function (Ports 1 to 4)</td></tr><tr><td class="align-middle">منافذ SFP</td><td>Two 1000BASE-SX/LX/BX SFP interfaces (Ports 9 to 10)<br /> متوافق مع 100BASE-FX SFP</td></tr><tr><td class="align-middle">وحدة التحكم</td><td>1 x RS232-to-RJ45 serial port (115200,8, N, 1)</td></tr><tr><td class="align-middle">زر إعادة الضبط</td><td>أقل من 5 ثوانٍ: إعادة تشغيل النظام<br /> &gt; 5 ثوانٍ: إعدادات المصنع الافتراضية</td></tr><tr><td class="align-middle">موصل</td><td>كتلة طرفية قابلة للإزالة بستة دبابيس<br /> الدبوس 1/2 للطاقة 1؛ الدبوس 3/4 لإنذار الأعطال؛ الدبوس 5/6 للطاقة 2</td></tr><tr><td class="align-middle">جهاز إنذار</td><td>مخرج مرحل واحد لانقطاع التيار الكهربائي. قدرة تحمل تيار مرحل الإنذار: 1 أمبير عند 24 فولت تيار متردد</td></tr><tr><td class="align-middle">متطلبات الطاقة</td><td>48~54V DC, 6A (max.) (>51V DC for PoE+ output recommended)</td></tr><tr><td class="align-middle">استهلاك الطاقة / تبديدها</td><td>Max. 6.72 watts/22.91BTU (system on)<br /> Max. 156 watts/531.96BTU (Full loading)</td></tr><tr><td class="align-middle">الأبعاد (العرض × العمق × الارتفاع)</td><td>76.8 x 107.3 x 152 mm</td></tr><tr><td class="align-middle">وزن</td><td>1043g</td></tr><tr><td class="align-middle">حاوية</td><td>علبة ألومنيوم IP30</td></tr><tr><td class="align-middle">تثبيت</td><td>طقم سكة DIN وحامل جداري</td></tr><tr><td class="align-middle">حماية من التفريغ الكهروستاتيكي</td><td>تفريغ التلامس 6 كيلو فولت تيار مستمر<br /> تفريغ هوائي 8 كيلو فولت تيار مستمر</td></tr><tr><td class="align-middle">قاد</td><td>نظام: <br /> القوة 1 (<font color="Green">أخضر</font>)<br /> القوة 2 (<font color="Green">أخضر</font>)<br /> إنذار الأعطال (<font color="Red">أحمر</font>)<br /> جرس (<font color="Green">أخضر</font>)<br /> RO(<font color="Green">أخضر</font>n)<br /> Per 10/100/1000T RJ45 PoE+ Ports (Port 1~Port 4)<br /> LNK/ACT (<font color="Green">أخضر</font>)<br /> استخدام تقنية PoE (<font color="Orange">العنبر</font>)<br /> Per 10/100/1000T RJ45Ports (Port 5~Port 8)<br /> LNK/ACT (<font color="Green">أخضر</font>) <br />  1000 LNK (<font color="Orange">العنبر</font>)<br /> Per SFP Interface: (Port 9~Port 10)<br /> 1000 LNK/ACT (<font color="Green">أخضر</font>n)<br /> 100 LNK/ACT (<font color="Orange">العنبر</font>)<br /> PoE Usage:<br />  30W, 60W, 90W, 120W (<font color="Orange">العنبر</font>)</td></tr></tbody><thead><tr><th colspan="2">مواصفات التبديل</th></tr></thead><tbody><tr><td class="align-middle">بنية التبديل</td><td>التخزين والإرسال</td></tr><tr><td class="align-middle">تبديل النسيج</td><td>20Gbps/non-blocking</td></tr><tr><td class="align-middle">معدل نقل البيانات في المحول 64 بايت</td><td>14.8Mpps @64 bytes</td></tr><tr><td class="align-middle">جدول عناوين MAC</td><td>8 آلاف مشاركة</td></tr><tr><td class="align-middle">مخزن البيانات المشترك</td><td>4.1 ميغابت</td></tr><tr><td class="align-middle">التحكم في التدفق</td><td>إطار الإيقاف المؤقت IEEE 802.3x للاتصال ثنائي الاتجاه الكامل<br /> ضغط خلفي لنصف دوبلكس</td></tr><tr><td class="align-middle">إطار جامبو</td><td>10 Kbytes</td></tr></tbody><thead><tr><th colspan="2">الطاقة عبر الإيثرنت</th></tr></thead><tbody><tr><td class="align-middle">معيار PoE</td><td>معيار IEEE 802.3at لتزويد الطاقة عبر الإيثرنت بلس/PSE</td></tr><tr><td class="align-middle">نوع مزود الطاقة PoE</td><td>نهاية الامتداد</td></tr><tr><td class="align-middle">تخصيص دبابيس الطاقة</td><td>1/2(+), 3/6(-)</td></tr><tr><td class="align-middle">مخرج طاقة PoE</td><td>معيار IEEE 802.3af<br /> - Per port 48V~51V DC, max. 15.4 watts <br /> معيار IEEE 802.3at<br /> - Per port 51V~54V DC, max. 36 watts</td></tr><tr><td class="align-middle">ميزانية طاقة PoE</td><td>Maximum 144W (depending on power input)</td></tr><tr><td class="align-middle">الحد الأقصى لعدد مديري التطوير المهني من الفئة الثانية</td><td>4</td></tr><tr><td class="align-middle">الحد الأقصى لعدد مديري التطوير المهني من الفئة 3</td><td>4</td></tr><tr><td class="align-middle">الحد الأقصى لعدد مديري التطوير المهني من الفئة 4</td><td>4</td></tr></tbody><thead><tr><th colspan="2">وظائف إدارة تقنية PoE</th></tr></thead><tbody><tr><td class="align-middle">إدارة نقاط الطاقة عبر الإيثرنت</td><td>فحص حالة المريض PD<br /> إعادة تدوير الطاقة المجدولة <br /> جدول PoE<br /> مراقبة استخدام تقنية PoE<br /> تمديد PoE</td></tr><tr><td class="align-middle">وضع PoE المحسّن</td><td>Standard/Legacy/Force</td></tr><tr><td class="align-middle">الكشف المباشر عن أجهزة PoE النشطة</td><td>نعم</td></tr><tr><td class="align-middle">إعادة تدوير طاقة PoE</td><td>نعم، جدول يومي أو جدول زمني محدد مسبقاً</td></tr><tr><td class="align-middle">جدول PoE</td><td>4 ملفات تعريف الجدول الزمني</td></tr><tr><td class="align-middle">وضع تمديد PoE</td><td>نعم، بحد أقصى يصل إلى 250 متراً</td></tr></tbody><thead><tr><th colspan="2">وظائف الطبقة الثانية</th></tr></thead><tbody><tr><td class="align-middle">نسخ المنفذ</td><td>إرسال/استقبال/كلاهما<br /> شاشة متعددة إلى واحد<br /> ما يصل إلى 4 جلسات</td></tr><tr><td class="align-middle">شبكة VLAN</td><td>شبكة VLAN موسومة بـ 802.1Q <br /> تقنية النفق Q-in-Q (تكديس الشبكات المحلية الظاهرية) 802.1ad<br /> شبكة VLAN الصوتية<br /> بروتوكول VLAN<br /> شبكة VLAN خاصة (منفذ محمي)<br /> GVRP<br /> شبكة VLAN للإدارة<br /> ما يصل إلى 256 مجموعة VLAN، من أصل 4094 معرف VLAN</td></tr><tr><td class="align-middle">تجميع الروابط</td><td>بروتوكول IEEE 802.3ad LACP والوصلة الثابتة<br /> Supports 5 groups with 8 ports per trunk</td></tr><tr><td class="align-middle">بروتوكول الشجرة الممتدة</td><td>بروتوكول الشجرة الممتدة IEEE 802.1D (STP)<br /> بروتوكول الشجرة الممتدة السريع IEEE 802.1w (RSTP)<br /> بروتوكول الشجرة الممتدة المتعددة IEEE 802.1s (MSTP)<br /> حماية بروتوكول الشجرة الممتدة (STP BPDU Guard)، وتصفية بروتوكول الشجرة الممتدة (BPDU Filtering)، وإعادة توجيه بروتوكول الشجرة الممتدة (BPDU Forwarding)</td></tr><tr><td class="align-middle">التجسس على بروتوكول إدارة مجموعات الإنترنت (IGMP)</td><td>مراقبة بروتوكول إدارة مجموعات الإنترنت IPv4 الإصدار 2، الإصدار 3<br /> مستعلم IGMP<br /> ما يصل إلى 256 مجموعة بث متعدد</td></tr><tr><td class="align-middle">التجسس على MLD</td><td>مراقبة بروتوكول MLD لبروتوكول IPv6 الإصدارين 2 و3، بما يصل إلى 256 مجموعة بث متعدد</td></tr><tr><td class="align-middle">قائمة التحكم بالوصول</td><td>قوائم التحكم بالوصول المستندة إلى بروتوكول الإنترنت IPv4/IPv6 / قوائم التحكم بالوصول المستندة إلى عنوان MAC<br /> IPv4/IPv6 ACE المستند إلى IP/MAC المستند إلى ACE</td></tr><tr><td class="align-middle">جودة الخدمة</td><td>8 معرّفات ربط بـ 8 مستويات من قوائم الانتظار ذات الأولوية <br /> رقم المنفذ <br /> أولوية 802.1p<br /> أولوية DSCP/IP لحزم IPv4/IPv6<br /> تصنيف حركة المرور، أولوية صارمة، وWRR<br /> التحكم في عرض النطاق الترددي لكل منفذ، مع تحديد معدل الإدخال/الإخراج</td></tr><tr><td class="align-middle">جرس</td><td>يدعم نظام ERPS، ويتوافق مع معيار ITU-T G.8032<br /> وقت التعافي &lt; 450 مللي ثانية</td></tr></tbody><thead><tr><th colspan="2">وظائف الأمان</th></tr></thead><tbody><tr><td class="align-middle">قائمة التحكم بالوصول</td><td>قوائم التحكم بالوصول المستندة إلى بروتوكول الإنترنت IPv4/IPv6 / قوائم التحكم بالوصول المستندة إلى عنوان MAC<br /> IPv4/IPv6 ACE المستند إلى IP/MAC المستند إلى ACE<br /> الحد الأقصى 256 إدخالًا في قائمة التحكم بالوصول</td></tr><tr><td class="align-middle">أمن الموانئ</td><td>معيار IEEE 802.1X – المصادقة المستندة إلى المنفذ<br /> عميل RADIUS مدمج للتعاون مع خادم RADIUS<br /> مصادقة وصول المستخدم RADIUS/TACACS+</td></tr><tr><td class="align-middle">أمان ماك</td><td>ربط منفذ IP-MAC<br /> مرشح MAC<br /> عنوان MAC ثابت، بحد أقصى 256 مدخل MAC ثابت</td></tr><tr><td class="align-middle">أمان مُعزز</td><td>مراقبة بروتوكول DHCP وخيار DHCP 82<br /> حماية بروتوكول الشجرة الممتدة (STP) لوحدات بيانات بروتوكول الشجرة الممتدة (BPDU)، وتصفية وحدات بيانات بروتوكول الشجرة الممتدة (BPDU)، وإعادة توجيه وحدات بيانات بروتوكول الشجرة الممتدة (BPDU).<br /> الوقاية من هجمات حجب الخدمة<br /> فحص ARP<br /> حماية مصدر IP</td></tr></tbody><thead><tr><th colspan="2">الوظائف الإدارية</th></tr></thead><tbody><tr><td class="align-middle">واجهات الإدارة الأساسية</td><td>وحدة تحكم RS232 إلى RJ45<br /> متصفح الويب<br /> تيلنت<br /> SNMP الإصدار 1، الإصدار 2c</td></tr><tr><td class="align-middle">واجهات إدارة آمنة</td><td>SSHv2، TLS v1.2، SNMP v3</td></tr><tr><td class="align-middle">إدارة النظام</td><td>ترقية البرامج الثابتة عبر بروتوكول HTTP/TFTP من خلال شبكة إيثرنت<br /> تحميل/تنزيل الإعدادات عبر HTTP/TFTP<br /> بروتوكول LLDP <br /> بروتوكول نقل الملفات البسيط (SNTP)<br /> أداة اكتشاف بلانيت الذكية<br /> نظام إدارة الشبكة بلانيت/كلاود فيور</td></tr><tr><td class="align-middle">إدارة الفعاليات</td><td>سجل النظام عن بعد/محلي<br /> سجل النظام</td></tr><tr><td class="align-middle">قواعد معلومات إدارة بروتوكول إدارة الشبكة البسيط (SNMP MIBs)</td><td>RFC 1213 MIB-II<br /> RFC 1215 الفخاخ العامة<br /> RFC 1493 Bridge MIB<br /> امتدادات قاعدة معلومات إدارة الجسر RFC 2674<br /> RFC 2737 Entity MIB (الإصدار 2)<br /> RFC 2819 RMON (1, 2, 3, 9)<br /> RFC 2863 مجموعة واجهة MIB<br /> RFC 3635 MIB شبيه بشبكة إيثرنت<br /> RFC 3621 Power Ethernet MIB</td></tr></tbody><thead><tr><th colspan="2">الامتثال للمعايير</th></tr></thead><tbody><tr><td class="align-middle">الامتثال التنظيمي</td><td>الجزء 15 من لجنة الاتصالات الفيدرالية، الفئة أ، علامة CE</td></tr><tr><td class="align-middle">اختبار الثبات</td><td>IEC 60068-2-32 (السقوط الحر)<br /> IEC 60068-2-27 (صدمة)<br /> IEC 60068-2-6 (الاهتزاز)</td></tr><tr><td class="align-middle">الامتثال للمعايير</td><td>IEEE 802.3 10BASE-T<br /> معيار IEEE 802.3u 100BASE-TX/100BASE-FX<br /> معيار IEEE 802.3z جيجابت SX/LX<br /> IEEE 802.3ab جيجابت 1000BASE-T<br /> التحكم في التدفق والضغط الخلفي وفقًا لمعيار IEEE 802.3x<br /> وصلة منفذ IEEE 802.3ad مع LACP<br /> بروتوكول الشجرة الممتدة IEEE 802.1D<br /> بروتوكول الشجرة الممتدة السريع IEEE 802.1w<br /> بروتوكول الشجرة الممتدة المتعددة IEEE 802.1s<br /> فئة الخدمة IEEE 802.1p<br /> وضع علامات VLAN وفقًا لمعيار IEEE 802.1Q<br /> التحكم في شبكة مصادقة المنافذ وفقًا لمعيار IEEE 802.1x<br /> بروتوكول LEDP 802.1ab من IEEE<br /> معيار IEEE 802.3af لتزويد الطاقة عبر الإيثرنت<br /> تقنية IEEE 802.3at Power over Ethernet Plus<br /> معيار IEEE 802.3az لشبكة إيثرنت موفرة للطاقة<br /> RFC 768 UDP<br /> بروتوكول نقل الملفات البسيط RFC 783<br /> RFC 791 IP<br /> RFC 792 ICMP<br /> RFC 2068 HTTP<br /> RFC 1112 IGMP الإصدار 1<br /> RFC 2236 IGMP الإصدار 2<br /> RFC 3376 IGMP الإصدار 3<br /> RFC 2710 MLD v1<br /> RFC 3810 MLD v2<br /> ITU G.8032 ERPS Ring</td></tr></tbody><thead><tr><th colspan="2">بيئة</th></tr></thead><tbody><tr><td class="align-middle">درجة حرارة التشغيل</td><td>-40 ~ 75 درجة مئوية</td></tr><tr><td class="align-middle">درجة حرارة التخزين</td><td>-40 ~ 85 درجة مئوية</td></tr><tr><td class="align-middle">رطوبة</td><td>5 ~ 95% (غير مكثف)</td></tr></tbody></table>
  • rank_math_news_sitemap_robots: فِهرِس
  • rank_math_robots: a:1:{i:0;s:5:"index";}
  • rank_math_internal_links_processed: 1
  • rank_math_primary_product_cat: 474
  • تاريخ دليل المستخدم 3: 20230207
  • دليل المستخدم الإصدار 3: 1.3
  • وصف دليل المستخدم 3: إصدار متوافق مع إصدار الجهاز 2.0.
  • users_manual_3_download_pdf: https://www.planet.com.sa/storage/products/igs-4215-4p4t2s-v2/EM-IGS-4215 PoE series_v1.3.pdf
  • ec_declaration_1_date: 20230426
  • ec_declaration_1_version: 2.0
  • ec_declaration_1_description: [إصدار للأجهزة الإصدار 2.0.] إعلان للجنة الاتصالات الفيدرالية.
  • ec_declaration_1_download_pdf: https://www.planet.com.sa/storage/products/igs-4215-4p4t2s-v2/IGS-4215-8P2T2Sv2_IGS-4215-4P4T2Sv2_IGS-4215-4P4Tv2_FCC.pdf
  • firmware_2_date: 20241230
  • firmware_2_version: 2.305b241115
  • firmware_2_description: [Release for hardware version 2.0.] Enhanced product security.
  • firmware_2_download_pdf: https://www.planet.com.tw/storage/products/49588/FW-IGS-4215-4P4T2S_v2.305b241115.zip
  • firmware_3_date: 20241106
  • firmware_3_version: 2.305b241016
  • firmware_3_description: [Release for hardware version 2.0.] Enhanced product security.
  • firmware_3_download_pdf: https://www.planet.com.tw/storage/products/49588/FW-IGS-4215-4P4T2S_v2.305b241016.zip
  • hide_related_products_tab: 0
  • rank_math_focus_keyword: IGS-4215-4P4T2S

Industrial 4-Port 10/100/1000T 802.3at PoE + 4-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Switch

» IGS-4215-4P4T2S

Cost-optimized Full PoE+ Power Solution Ideal for Hardened Environment

Designed to be installed in heavy industrial  environments, the IGS-4215-4P4T2S is the new model of PLANET Industrial-grade, DIN-rail type L2/L4 Managed Gigabit PoE+ Switch family featuring PLANET intelligent PoE functions to improve the availability of critical business applications. It provides IPv6/IPv4 dual stack management and built-in L2/L4 Gigabit switching engine along with 4 10/100/1000BASE-T منافذ تتميز 36-watt 802.3at PoE+, 4 additional Gigabit copper ports and another 2 extra 100/1000BASE-X SFP fiber slots for data and video uplink. The IGS-4215-4P4T2S is able to operate reliably, stably and quietly in any hardened environment without affecting its performance. It comes with a total power budget of up to 144 watts for different kinds of PoE applications and operating temperature ranging from من -40 إلى 75 درجة مئوية in a rugged IP30 metal housing.

 

IGS 4215 4P4T2Sv2 3

 

حلول شبكات الأمن السيبراني لتقليل المخاطر الأمنية

The IGS-4215-4P4T2S supports SSHv2 and TLSv1.2 protocols to provide strong protection against advanced threats. It includes a range of cybersecurity features such as DHCP Snooping, IP Source Guard, dynamic ARP Inspection Protection, 02.1x port-based network access control, RADIUS and TACACS+ user accounts management, SNMPv3 authentication, and so on to complement it as an all-security solution. 

IGS 4215 4P4T2Sv2 1 N

 

حلقة احتياطية، استعادة سريعة لتطبيقات الشبكة الحيوية

The IGS-4215-4P4T2S supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced ITU-T G.8032 ERPS (Ethernet Ring Protection Switching) technology, Spanning Tree Protocol (802.1s MSTP) into customer’s network to enhance system reliability and uptime in various environments.

IGS 4215 8T2S 21

 

وظائف PoE فريدة مدمجة لإدارة الأجهزة التي تعمل بالطاقة

As the industrial PoE+ managed switch for surveillance, wireless and VoIP networks, the IGS-4215-4P4T2S features special PoE management functions:

  • فحص حالة PD
  • إعادة تدوير الطاقة المجدولة
  • جدول PoE
  • PoE usage monitoring
  • تمديد PoE

 

فحص حالة الجهاز الذكي

The IGS-4215-4P4T2S can be configured to monitor connected PD (powered device) status in real time via ping action. Once the PD stops working and responding, the IGS-4215-4P4T2S will resume the PoE port power and bring the PD back to work. It will greatly enhance the network reliability through the PoE port resetting the PD’s power source and reducing the administrator’s management burden.

 

Common PD Alive Check

 

إعادة تدوير الطاقة المجدولة

The IGS-4215-4P4T2S allows each of the connected PoE IP cameras or PoE wireless access points to reboot at a specified time each week. Therefore, it will reduce the chance of IP camera or AP crash resulting from buffer overflow. 

 

 

Common Scheduled Power Recycling

 

جدول PoE لتوفير الطاقة

Under the global trend of energy saving and contributing to environmental protection, the IGS-4215-4P4T2S can effectively control the power supply besides its capability of giving high watts power. The “PoE schedule” function helps you to enable or disable PoE power feeding for each PoE port during specified time intervals, which is a powerful function to help SMBs or enterprises save power and budget. It also increases security by powering off PDs that should not be in use during non-business hours.

Common PoE Schedule for Energy Saving

 

Intelligent LED Indicator for Real-time PoE Usage Monitoring

Via the power usage chart in the web management interface, the IGS-4215-4P4T2S enables the administrator to monitor the status of the power usage of the connected PDs in real time. Thus, it greatly enhances the management efficiency of the facilities. Moreover, the IGS-4215-4P4T2S helps users to monitor the current status of PoE power usage easily and efficiently via its advanced LED indication. Called “استهلاك الطاقة عبر تقنية PoE”, the front panel of the IGS-4215-4P4T2S has four amber LEDs indicating four different PoE power usages, namely 30W, 60W, 90W, and 120W.

 

IGS 4215 4P4T2Sv2 2

 

802.3at PoE+ طاقة وتمديد مسافة نقل بيانات الإيثرنت

في "“Extend” operation mode, the IGS-4215-4P4T2S operates on a per-port basis at 10Mbps duplex operation but can support 20-watt PoE power output over a distance of up to 250 meters overcoming the 100m limit on Ethernet UTP cable. With this brand-new feature, the IGS-4215-4P4T2S provides an additional solution for 802.3at/af PoE distance extension, thus saving the cost of Ethernet cable installation. 

 

Common PoE switch Extend Mode

تصميم مقاوم للظروف البيئية

With the IP30 aluminum industrial case, the IGS-4215-4P4T2S provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curb-side traffic control cabinets without air conditioner. Being able to operate under the temperature range from -40 to 75 degrees C, the IGS-4215-4P4T2S can be placed in almost any difficult environment.

 

حماية قوية

The IGS-4215-4P4T2S provides contact discharge of ±6KV DC and air discharge of ±8KV DC for Ethernet ESD protection. It also supports ±4KV surge immunity to improve product stability and protects users’ networks from devastating ESD attacks, making sure the flow of operation does not fluctuate.

 

إدارة بروتوكول IPv6/IPv4 المزدوج

Supporting both IPv6 and IPv4 protocols, the IGS-4215-4P4T2S helps the SMBs to step in the IPv6 era with the lowest investment as its network facilities need not be replaced or overhauled if the IPv6 FTTx edge network is set up. 

Common IPv6 IPv4 Dual Stack Management

 

ميزات الطبقة الثانية القوية

The IGS-4215-4P4T2S can be programmed for advanced switch management functions such as dynamic port link aggregation, 802.1Q VLAN, شبكة VLAN من نوع Q-in-Q، وبروتوكول الشجرة الممتدة المتعددة (MSTP), حلقة و حارس وحدة توزيع الطاقة (BPDU), التجسس على بروتوكول إدارة مجموعات الإنترنت (IGMP), ، و التجسس على MLD. Via the link aggregation, the IGS-4215-4P4T2S allows the operation of a high-speed trunk to combine with multiple ports such as an 8Gbps fat pipe, and supports fail-over as well.  Also, the بروتوكول اكتشاف طبقة الربط (LLDP) هل بروتوكول الطبقة الثانية مُضمن للمساعدة في اكتشاف المعلومات الأساسية حول الأجهزة المجاورة في نطاق البث المحلي؟.

Common Robust Layer 2 Features

إدارة حركة المرور بكفاءة

The IGS-4215-4P4T2S is loaded with robust QoS features and powerful traffic management to enhance services to business-class data, voice, and video solutions. The functionality includes broadcast/multicast/unicast مكافحة العواصف, لكل ميناء bandwidth control, 802.1p/CoS/IP DSCP QoS priority and remarking. It guarantees the best performance in VoIP and video stream transmission, and empowers the enterprises to take full advantage of the limited network resources.

 

أمان قوي

PLANET IGS-4215-4P4T2S offers comprehensive IPv4/IPv6 من الطبقة 2 إلى الطبقة 4 قائمة التحكم بالوصول (ACL) لتعزيز الأمن على مستوى الحافة. يمكن استخدامه لتقييد الوصول إلى الشبكة عن طريق رفض الحزم بناءً على عنوان IP المصدر والوجهة، أو منافذ TCP/UDP، أو تطبيقات الشبكة النموذجية المحددة. كما تتضمن آلية الحماية الخاصة به 802.1X قائم على المنافذ مصادقة المستخدم والجهاز، والتي يمكن نشرها مع RADIUS لضمان أمان مستوى المنفذ ومنع المستخدمين غير المصرح لهم. منفذ محمي يمكن منع الاتصال بين منافذ الحافة لضمان خصوصية المستخدم. علاوة على ذلك،, أمن الموانئ تتيح هذه الوظيفة تحديد عدد أجهزة الشبكة المتصلة بمنفذ معين. وبذلك، أصبح بإمكان مديري الشبكات إنشاء شبكات مؤسسية عالية الأمان بجهد ووقت أقل بكثير من السابق.

 

إدارة سهلة الاستخدام وآمنة 

For efficient management, the IGS-4215-4P4T2S is equipped with Command line, Web and SNMP management interfaces.

  • مع المدمج عبر الإنترنت management interface, the IGS-4215-4P4T2S offers an easy-to-use, platform-independent management and configuration facility.
  • ل نصي ويمكن الوصول إلى نظام الإدارة عبر Telnet ومنفذ وحدة التحكم.
  • من خلال دعم بروتوكول SNMP القياسي، يمكن إدارة المحول عبر أي برنامج إدارة قائم على SNMP.

 

Moreover, the IGS-4215-4P4T2S offers secure remote management by supporting SSHv2، TLSv1.2 و SNMP الإصدار 3 الاتصالات التي تشفر محتوى الحزمة في كل جلسة.

 

 

Common Secure Management

 

حلول مرنة لتمديد المكالمات لمسافات طويلة

The two SFP slots built in the IGS-4215-4P4T2S support SFP auto-detection and dual speed as it features 100BASE-FX و 1000BASE-SX/LX SFP (Small Form-factor Pluggable) fiber transceivers to uplink to backbone switch and monitoring center in long distance. The distance can be extended from 550 meters to 2 kilometers (multi-mode fiber) and to 10/20/40/60/80/120 kilometers (single-mode fiber or WDM fiber). They are well suited for applications within the enterprise data centers and distributions.

 

آلية تشخيص ذكية لمرض SFP

The IGS-4215-4P4T2S supports جهاز مراقبة التشخيص الرقمي (SFP-DDM) وظيفة يمكنها بسهولة مراقبة معلمات SFP في الوقت الحقيقي لمسؤول الشبكة، مثل طاقة الإخراج الضوئي، وطاقة الإدخال الضوئي، ودرجة الحرارة، وتيار انحياز الليزر، وجهد إمداد جهاز الإرسال والاستقبال.

 

Common Intelligent SFP SFP+ Diagnosis Mechanism

ITU-T G.8032 ERPS Makes Data Transmission Uninterrupted 

The IGS-4215-4P4T2S features strong rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates ITU-T G.8032 ERPS (تبديل حماية حلقة الإيثرنت) technology into customer’s automation network to enhance system reliability and uptime. Applying the IEEE 802.3at Power over Ethernet standard, the IGS-4215-4P4T2S can directly connect with any IEEE 802.3at end-nodes like PTZ (Pan, Tilt & Zoom) network cameras and speed dome cameras. The IGS-4215-4P4T2S can easily help system integrators with the available network infrastructure to build wireless AP, IP camera and VoIP systems where power can be centrally-controlled.

 

 

Industrial-grade PoE+ Switch for Building Automation and Security

Suitable for buildings where security is strictly to be enforced, the IGS-4215-4P4T2S, with 4 802.3at PoE+, in-line power interfaces, can easily build a power centrally controlled for an IP phone system, IP surveillance system, and wireless AP group in the harsh Industrial environment. For instance, 4 PoE IP cameras or PoE wireless APs can be easily installed for surveillance demands or a wireless roaming environment in the industrial area can be built. Without the power-socket limitation, the IGS-4215-4P4T2S makes the installation of IP cameras or wireless APs easier and more efficient.

 

 

حل تكامل مثالي لكاميرات IP PoE وأنظمة NVR

The IGS-4215-4P4T2S provides 4 10/100/1000BASE-T 802.3at PoE+ ports which can offer sufficient PoE power to 4 PoE IP cameras at the same time. In addition, with the two 100/1000BASE-X SFP interfaces, the IGS-4215-4P4T2S can connect to a core fiber switch and send video streams to an NVR and monitoring center. Through the high-performance switch architecture, the IGS-4215-4P4T2S facilitates the recorded video files from the 4 PoE+ IP cameras to be saved in the NVR systems. Furthermore, the NVR systems can be controlled and monitored in both the local LAN and the remote site via Internet. The IGS-4215-4P4T2S undoubtedly brings an ideal secure surveillance system at a lower total cost.

 

منفذ فعلي

  • Eight 10/100/1000BASE-T Gigabit Ethernet RJ45 ports (Ports 1 to 8)
  • Four منافذ مع IEEE 802.3at/af PoE+ Injector function (Ports 1 to 4)
  • Two 100/1000BASE-X SFP slots for SFP type auto detection (Ports 9 to 10)
  • واجهة وحدة تحكم RJ45 واحدة للإدارة والإعداد الأساسيين

 

الطاقة عبر الإيثرنت

  • يتوافق مع معيار IEEE 802.3at Power over Ethernet Plus، وPSE الطرفي
  • متوافق مع الإصدارات السابقة من معيار IEEE 802.3af لتزويد الطاقة عبر الإيثرنت
  • يدعم ما يصل إلى 4 منافذ من أجهزة IEEE 802.3af/802.3at
  • 144-watt PoE budget
  • يدعم طاقة PoE تصل إلى 36 واط لكل منفذ PoE
  • الكشف التلقائي عن الأجهزة التي تعمل بالطاقة (PD)
  • تمنع حماية الدائرة تداخل الطاقة بين المنافذ
  • تغذية الطاقة عن بعد لمسافة تصل إلى 100 متر في الوضع القياسي و250 متر في وضع التمديد
  • إدارة نقاط التزويد بالطاقة (PoE)
    • التحكم الكامل في ميزانية طاقة PoE
    • تفعيل/تعطيل وظيفة PoE لكل منفذ
    • أولوية تزويد منفذ PoE بالطاقة
    • تحديد الطاقة لكل منفذ PoE
    • تصنيف مرض باركنسون
  • ميزات PoE الذكية
    • فحص حالة PD
    • جدول PoE

 

علبة صناعية وتركيب

  • علبة ألومنيوم IP30 
  • تصميم للتركيب على سكة DIN أو على الحائط
  • 48~54 فولت تيار مستمر، طاقة احتياطية مع حماية من عكس القطبية
  • يدعم حماية من التفريغ الكهروستاتيكي عبر الإيثرنت بجهد 6000 فولت تيار مستمر
  • درجة حرارة التشغيل من -40 إلى 75 درجة مئوية 

 

التبديل

  • Hardware-based 10/100Mbps (half/full duplex), 1000Mbps (full duplex), auto-negotiation and uto MDI/MDI-X
  • التحكم في التدفق وفقًا لمعيار IEEE 802.3x للتشغيل ثنائي الاتجاه الكامل، والتحكم في الضغط الخلفي للتشغيل ثنائي الاتجاه الجزئي
  • حجم جدول عناوين MAC 8K
  • إطار جامبو 10K
  • التعلم التلقائي للعناوين وتقادم العناوين

 

ميزات الطبقة الثانية

  • يدعم شبكة VLAN
    • شبكة VLAN الموسومة IEEE 802.1Q
    • دعم ربط الموفر (VLAN Q-in-Q، IEEE 802.1ad)
    • بروتوكول VLAN
    • شبكة VLAN الصوتية
    • شبكة VLAN خاصة (منفذ محمي)
    • شبكة VLAN للإدارة
    • GVRP
  • يدعم بروتوكول الشجرة الممتدة
    • بروتوكول الشجرة الممتدة (STP)
    • بروتوكول الشجرة الممتدة السريعة (RSTP)
    • بروتوكول الشجرة الممتدة المتعددة (MSTP)
    • حماية بروتوكول الشجرة الممتدة (STP BPDU Guard)، وتصفية بروتوكول الشجرة الممتدة (BPDU Filtering)، وإعادة توجيه بروتوكول الشجرة الممتدة (BPDU Forwarding)
  • يدعم تجميع الروابط
    • بروتوكول التحكم في تجميع الروابط IEEE 802.3ad (LACP)
    • قناة إيثرنت سيسكو (جذع ثابت)
    • Supports 5 groups with 8 ports per trunk
  • يوفر خاصية النسخ المتطابق للمنفذ (من متعدد إلى واحد)
  • حماية من الحلقات لتجنب حلقات البث
  • يدعم تقنية ERPS (تبديل حماية حلقة الإيثرنت)
  • بروتوكول اكتشاف طبقة الربط (LLDP) 

 

جودة الخدمة

  • التحكم في عرض النطاق الترددي لكل منفذ، مع تحديد معدل الإدخال/الإخراج
  • تصنيف حركة المرور
    • IEEE 802.1p CoS
    • أولوية TOS/DSCP/IP لحزم IPv4/IPv6
  • سياسات الأولوية الصارمة والتناوب المرجح (WRR) لعقد الخدمة

 

البث المتعدد

  • يدعم بروتوكول مراقبة IGMP الإصدار 2 و 3 من بروتوكول IPv4
  • يدعم بروتوكول IPv6 MLD snooping الإصدارين 1 و2
  • دعم وضع استعلام IGMP
  • تصفية منافذ التجسس على بروتوكول إدارة مجموعات الإنترنت (IGMP)
  • تصفية منافذ التجسس MLD

 

حماية

  • دعم مكافحة العواصف
    • Broadcast/ unknown multicast/unknown unicast
  • المصادقة
    • مصادقة الوصول إلى الشبكة المستندة إلى المنافذ وفقًا لمعيار IEEE 802.1X
    • عميل RADIUS مدمج للتعاون مع خوادم RADIUS
    • خيار DHCP رقم 82
    • مصادقة RADIUS/TACACS+ 
  • قائمة التحكم بالوصول
    • قوائم التحكم بالوصول المستندة إلى بروتوكول الإنترنت IPv4/IPv6
    • نظام التحكم في الوصول القائم على بروتوكول الإنترنت IPv4/IPv6
    • التحكم في الوصول القائم على MAC
    • ACE القائم على MAC
  • أمان ماك
    • عنوان MAC ثابت
    • تصفية عناوين MAC
  • أمان المنفذ لتصفية إدخالات عنوان MAC المصدر
  • مراقبة بروتوكول DHCP لتصفية رسائل DHCP غير الموثوقة
  • يقوم فحص ARP الديناميكي بتجاهل حزم ARP التي تحتوي على ربط غير صالح بين عنوان MAC وعنوان IP
  • يحمي نظام حماية مصدر IP من هجمات انتحال عناوين IP
  • الوقاية من هجمات حجب الخدمة

 

إدارة

  • إدارة المكدس المزدوج لـ IPv4 و IPv6
  • واجهة إدارة المحول
    • إدارة تبديل الويب 
    • واجهة سطر الأوامر Console/Telnet 
    • إدارة المحولات SNMP الإصدار 1 والإصدار 2c
    • الوصول الآمن عبر SSHv2 وTLSv1.2 وSNMP v3
  • إدارة بروتوكول إدارة الشبكة البسيط (SNMP)
    • تنبيه SNMP لحالة اتصال الواجهة (تشغيل/إيقاف)
    • أربع مجموعات RMON (التاريخ، والإحصائيات، والإنذارات، والأحداث) 
  • التحكم في مستويات امتيازات المستخدم
  • عميل بروتوكول نقل الملفات البسيط (TFTP) المدمج
  • تخصيص عناوين IP الثابتة و DHCP
  • صيانة النظام
    • تحميل/تنزيل البرامج الثابتة عبر HTTP/TFTP
    • تحميل/تنزيل الإعدادات عبر HTTP/TFTP
    • صور مزدوجة
    • زر إعادة ضبط الجهاز لإعادة تشغيل النظام أو إعادة ضبطه إلى إعدادات المصنع الافتراضية
  • بروتوكول وقت الشبكة SNTP
  • تشخيص الشبكة
    • تشخيص الكابلات
    • اختبار الاتصال عن بعد ICMPv6/ICMPv4
    • جهاز مراقبة التشخيص الرقمي (SFP-DDM)
  • بروتوكول اكتشاف طبقة الربط (LLDP) وبروتوكول LLDP-MED
  • تسجيل رسائل الأحداث على خادم syslog البعيد
  • أداة PLANET Smart Discovery لإدارة عمليات النشر
  • نظام إدارة الشبكة PLANET وCloudViewer لإدارة النشر

مواصفات الأجهزة
موانئ نحاسيةEight 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports (Ports 1 to 8)
منفذ حقن PoEFour ports with 802.3af/802.3at PoE+ injector function (Ports 1 to 4)
منافذ SFPTwo 1000BASE-SX/LX/BX SFP interfaces (Ports 9 to 10)
متوافق مع 100BASE-FX SFP
وحدة التحكم1 x RS232-to-RJ45 serial port (115200,8, N, 1)
زر إعادة الضبطأقل من 5 ثوانٍ: إعادة تشغيل النظام
> 5 ثوانٍ: إعدادات المصنع الافتراضية
موصلكتلة طرفية قابلة للإزالة بستة دبابيس
الدبوس 1/2 للطاقة 1؛ الدبوس 3/4 لإنذار الأعطال؛ الدبوس 5/6 للطاقة 2
جهاز إنذارمخرج مرحل واحد لانقطاع التيار الكهربائي. قدرة تحمل تيار مرحل الإنذار: 1 أمبير عند 24 فولت تيار متردد
متطلبات الطاقة48~54V DC, 6A (max.) (>51V DC for PoE+ output recommended)
استهلاك الطاقة / تبديدهاMax. 6.72 watts/22.91BTU (system on)
Max. 156 watts/531.96BTU (Full loading)
الأبعاد (العرض × العمق × الارتفاع)76.8 x 107.3 x 152 mm
وزن1043g
حاويةعلبة ألومنيوم IP30
تثبيتطقم سكة DIN وحامل جداري
حماية من التفريغ الكهروستاتيكيتفريغ التلامس 6 كيلو فولت تيار مستمر
تفريغ هوائي 8 كيلو فولت تيار مستمر
قادنظام:
القوة 1 (أخضر)
القوة 2 (أخضر)
إنذار الأعطال (أحمر)
جرس (أخضر)
RO(أخضرn)
Per 10/100/1000T RJ45 PoE+ Ports (Port 1~Port 4)
LNK/ACT (أخضر)
استخدام تقنية PoE (العنبر)
Per 10/100/1000T RJ45Ports (Port 5~Port 8)
LNK/ACT (أخضر)
 1000 LNK (العنبر)
Per SFP Interface: (Port 9~Port 10)
1000 LNK/ACT (أخضرn)
100 LNK/ACT (العنبر)
PoE Usage:
 30W, 60W, 90W, 120W (العنبر)
مواصفات التبديل
بنية التبديلالتخزين والإرسال
تبديل النسيج20Gbps/non-blocking
معدل نقل البيانات في المحول 64 بايت14.8Mpps @64 bytes
جدول عناوين MAC8 آلاف مشاركة
مخزن البيانات المشترك4.1 ميغابت
التحكم في التدفقإطار الإيقاف المؤقت IEEE 802.3x للاتصال ثنائي الاتجاه الكامل
ضغط خلفي لنصف دوبلكس
إطار جامبو10 Kbytes
الطاقة عبر الإيثرنت
معيار PoEمعيار IEEE 802.3at لتزويد الطاقة عبر الإيثرنت بلس/PSE
نوع مزود الطاقة PoEنهاية الامتداد
تخصيص دبابيس الطاقة1/2(+), 3/6(-)
مخرج طاقة PoEمعيار IEEE 802.3af
- Per port 48V~51V DC, max. 15.4 watts
معيار IEEE 802.3at
- Per port 51V~54V DC, max. 36 watts
ميزانية طاقة PoEMaximum 144W (depending on power input)
الحد الأقصى لعدد مديري التطوير المهني من الفئة الثانية4
الحد الأقصى لعدد مديري التطوير المهني من الفئة 34
الحد الأقصى لعدد مديري التطوير المهني من الفئة 44
وظائف إدارة تقنية PoE
إدارة نقاط الطاقة عبر الإيثرنتفحص حالة المريض PD
إعادة تدوير الطاقة المجدولة
جدول PoE
مراقبة استخدام تقنية PoE
تمديد PoE
وضع PoE المحسّنStandard/Legacy/Force
الكشف المباشر عن أجهزة PoE النشطةنعم
إعادة تدوير طاقة PoEنعم، جدول يومي أو جدول زمني محدد مسبقاً
جدول PoE4 ملفات تعريف الجدول الزمني
وضع تمديد PoEنعم، بحد أقصى يصل إلى 250 متراً
وظائف الطبقة الثانية
نسخ المنفذإرسال/استقبال/كلاهما
شاشة متعددة إلى واحد
ما يصل إلى 4 جلسات
شبكة VLANشبكة VLAN موسومة بـ 802.1Q
تقنية النفق Q-in-Q (تكديس الشبكات المحلية الظاهرية) 802.1ad
شبكة VLAN الصوتية
بروتوكول VLAN
شبكة VLAN خاصة (منفذ محمي)
GVRP
شبكة VLAN للإدارة
ما يصل إلى 256 مجموعة VLAN، من أصل 4094 معرف VLAN
تجميع الروابطبروتوكول IEEE 802.3ad LACP والوصلة الثابتة
Supports 5 groups with 8 ports per trunk
بروتوكول الشجرة الممتدةبروتوكول الشجرة الممتدة IEEE 802.1D (STP)
بروتوكول الشجرة الممتدة السريع IEEE 802.1w (RSTP)
بروتوكول الشجرة الممتدة المتعددة IEEE 802.1s (MSTP)
حماية بروتوكول الشجرة الممتدة (STP BPDU Guard)، وتصفية بروتوكول الشجرة الممتدة (BPDU Filtering)، وإعادة توجيه بروتوكول الشجرة الممتدة (BPDU Forwarding)
التجسس على بروتوكول إدارة مجموعات الإنترنت (IGMP)مراقبة بروتوكول إدارة مجموعات الإنترنت IPv4 الإصدار 2، الإصدار 3
مستعلم IGMP
ما يصل إلى 256 مجموعة بث متعدد
التجسس على MLDمراقبة بروتوكول MLD لبروتوكول IPv6 الإصدارين 2 و3، بما يصل إلى 256 مجموعة بث متعدد
قائمة التحكم بالوصولقوائم التحكم بالوصول المستندة إلى بروتوكول الإنترنت IPv4/IPv6 / قوائم التحكم بالوصول المستندة إلى عنوان MAC
IPv4/IPv6 ACE المستند إلى IP/MAC المستند إلى ACE
جودة الخدمة8 معرّفات ربط بـ 8 مستويات من قوائم الانتظار ذات الأولوية
رقم المنفذ
أولوية 802.1p
أولوية DSCP/IP لحزم IPv4/IPv6
تصنيف حركة المرور، أولوية صارمة، وWRR
التحكم في عرض النطاق الترددي لكل منفذ، مع تحديد معدل الإدخال/الإخراج
جرسيدعم نظام ERPS، ويتوافق مع معيار ITU-T G.8032
زمن الاسترداد < 450 مللي ثانية
وظائف الأمان
قائمة التحكم بالوصولقوائم التحكم بالوصول المستندة إلى بروتوكول الإنترنت IPv4/IPv6 / قوائم التحكم بالوصول المستندة إلى عنوان MAC
IPv4/IPv6 ACE المستند إلى IP/MAC المستند إلى ACE
الحد الأقصى 256 إدخالًا في قائمة التحكم بالوصول
أمن الموانئمعيار IEEE 802.1X – المصادقة المستندة إلى المنفذ
عميل RADIUS مدمج للتعاون مع خادم RADIUS
مصادقة وصول المستخدم RADIUS/TACACS+
أمان ماكربط منفذ IP-MAC
مرشح MAC
عنوان MAC ثابت، بحد أقصى 256 مدخل MAC ثابت
أمان مُعززمراقبة بروتوكول DHCP وخيار DHCP 82
حماية بروتوكول الشجرة الممتدة (STP) لوحدات بيانات بروتوكول الشجرة الممتدة (BPDU)، وتصفية وحدات بيانات بروتوكول الشجرة الممتدة (BPDU)، وإعادة توجيه وحدات بيانات بروتوكول الشجرة الممتدة (BPDU).
الوقاية من هجمات حجب الخدمة
فحص ARP
حماية مصدر IP
الوظائف الإدارية
واجهات الإدارة الأساسيةوحدة تحكم RS232 إلى RJ45
متصفح الويب
تيلنت
SNMP الإصدار 1، الإصدار 2c
واجهات إدارة آمنةSSHv2، TLS v1.2، SNMP v3
إدارة النظامترقية البرامج الثابتة عبر بروتوكول HTTP/TFTP من خلال شبكة إيثرنت
تحميل/تنزيل الإعدادات عبر HTTP/TFTP
بروتوكول LLDP
بروتوكول نقل الملفات البسيط (SNTP)
أداة اكتشاف بلانيت الذكية
نظام إدارة الشبكة بلانيت/كلاود فيور
إدارة الفعالياتسجل النظام عن بعد/محلي
سجل النظام
قواعد معلومات إدارة بروتوكول إدارة الشبكة البسيط (SNMP MIBs)RFC 1213 MIB-II
RFC 1215 الفخاخ العامة
RFC 1493 Bridge MIB
امتدادات قاعدة معلومات إدارة الجسر RFC 2674
RFC 2737 Entity MIB (الإصدار 2)
RFC 2819 RMON (1, 2, 3, 9)
RFC 2863 مجموعة واجهة MIB
RFC 3635 MIB شبيه بشبكة إيثرنت
RFC 3621 Power Ethernet MIB
الامتثال للمعايير
الامتثال التنظيميالجزء 15 من لجنة الاتصالات الفيدرالية، الفئة أ، علامة CE
اختبار الثباتIEC 60068-2-32 (السقوط الحر)
IEC 60068-2-27 (صدمة)
IEC 60068-2-6 (الاهتزاز)
الامتثال للمعاييرIEEE 802.3 10BASE-T
معيار IEEE 802.3u 100BASE-TX/100BASE-FX
معيار IEEE 802.3z جيجابت SX/LX
IEEE 802.3ab جيجابت 1000BASE-T
التحكم في التدفق والضغط الخلفي وفقًا لمعيار IEEE 802.3x
وصلة منفذ IEEE 802.3ad مع LACP
بروتوكول الشجرة الممتدة IEEE 802.1D
بروتوكول الشجرة الممتدة السريع IEEE 802.1w
بروتوكول الشجرة الممتدة المتعددة IEEE 802.1s
فئة الخدمة IEEE 802.1p
وضع علامات VLAN وفقًا لمعيار IEEE 802.1Q
التحكم في شبكة مصادقة المنافذ وفقًا لمعيار IEEE 802.1x
بروتوكول LEDP 802.1ab من IEEE
معيار IEEE 802.3af لتزويد الطاقة عبر الإيثرنت
تقنية IEEE 802.3at Power over Ethernet Plus
معيار IEEE 802.3az لشبكة إيثرنت موفرة للطاقة
RFC 768 UDP
بروتوكول نقل الملفات البسيط RFC 783
RFC 791 IP
RFC 792 ICMP
RFC 2068 HTTP
RFC 1112 IGMP الإصدار 1
RFC 2236 IGMP الإصدار 2
RFC 3376 IGMP الإصدار 3
RFC 2710 MLD v1
RFC 3810 MLD v2
ITU G.8032 ERPS Ring
بيئة
درجة حرارة التشغيل-40 ~ 75 درجة مئوية
درجة حرارة التخزين-40 ~ 85 درجة مئوية
رطوبة5 ~ 95% (غير مكثف)
تاريخإصداروصفتحميل
2023/01/122.0

IGS-4215-4P4T2S

Download Icon
تاريخإصداروصفتحميل
2024/05/072.2

[إصدار للأجهزة الإصدار 2.0.]
تمت إضافة وظيفة PSTI.

Download Icon
2023/23/092.1

Add IGS-4215-16P2T2S.

Download Icon
2023/07/012.0

إصدار متوافق مع إصدار الجهاز 2.0.

Download Icon
تاريخإصداروصفتحميل
2025/11/092.1

[إصدار للأجهزة الإصدار 2.0.]
قم بتعديل محتويات دليل الأوامر.

Download Icon
2025/16/011.5

[إصدار للأجهزة الإصدار 2.0.]
تمت إضافة وظيفة PSTI.

Download Icon
2023/28/042.0

[دليل الأوامر]
إصدار متوافق مع إصدار الجهاز 2.0.

Download Icon
2023/07/021.3

إصدار متوافق مع إصدار الجهاز 2.0.

Download Icon
تاريخإصداروصفتحميل
2023/26/042.0

إصدار متوافق مع إصدار الجهاز 2.0.

Download Icon
2023/26/042.0

[إصدار للأجهزة الإصدار 2.0.]
إعلان للجنة الاتصالات الفيدرالية.

Download Icon
تاريخإصداروصفتحميل
2025/20/102.305b251017

[إصدار للأجهزة الإصدار 2.0.]
دعم نظام إدارة الشبكة السحابية PLANET.

Download Icon
2025/23/072.305b250717

[إصدار للأجهزة الإصدار 2.0.]
تعزيز أمان المنتج.

Download Icon
2024/30/122.305b241115

[إصدار للأجهزة الإصدار 2.0.]
تعزيز أمان المنتج.

Download Icon
2024/06/112.305b241016

[إصدار للأجهزة الإصدار 2.0.]
تعزيز أمان المنتج.

Download Icon

معلومات الطلب

IGS-4215-4P4T2S

Industrial 4-Port 10/100/1000T 802.3at PoE + 4-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Switch

معلومات الطلب

IGS-4215-4P4T2S

Industrial 4-Port 10/100/1000T 802.3at PoE + 4-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Switch
✉

انضم إلى قائمتنا البريدية

احصل على آخر الأخبار والعروض والتحديثات من شركة بلانيت تكنولوجي مباشرة إلى بريدك الإلكتروني.

نحن نحترم خصوصيتك. يمكنك إلغاء الاشتراك في أي وقت.

اشترك في النشرة الإخبارية الإلكترونية لـ PLANET

احصل على أحدث معلومات المنتجات وأخبار الشركة!