Outstanding 802.3bt PoE++ Solution for Heavy Industrial Environment
مع EN 61000-6-2 و 61000-6-4 Heavy Industrial EMC, and railway EN 50121-4 certified design, and complying with the IEEE 802.3bt PoE++ technology, PLANET IGS-6329-8UP2S4X provides non-stop data communication and reliable PoE injection, even with noise interferences coming from the heavy industrial field applications.
Complying with the IEEE 802.3bt Power over Ethernet Plus Plus technology, PLANET IGS-6329-8UP2S4X L3 Industrial Managed PoE++ Switch series features eight 10/100/1000BASE-T 802.3bt PoE++ ports with each port powering up to 95 واط, two 100/1000/2500BASE-X SFP and up to four 10G SFP+ ports interfaces in a rugged IP30 metal case for stable operation in heavy industrial demanding environments. It supports rich PoE operation modes including 90-watt 802.3bt type-4 PoE++ ports, 95-watt PoH (Power over HD-BASE-T) mode and 4-pair force mode to solve the incompatibility of non-standard 4-pair PoE PDs in the field.
Being able to operate under wide temperature range from -40 to 75 degrees C, the IGS-6329 PoE++ Switch series can be placed in almost any difficult environment. The IGS-6329 PoE++ Switch series also allows either DIN rail or wall mounting for efficient use of cabinet space.
802.3bt PoE++ – 90~95-watt Power over 4-pair UTP Solution
As the IGS-6329 PoE++ Series adopts the IEEE 802.bt PoE++ standard and PoH technology, it is capable of sourcing up to 95 واط of power by using all the four pairs of standard Cat5e/6 Ethernet cabling to deliver power and full-speed data to each remote PoE compliant powered device (PD). It possesses the power capacity that is triple than the conventional 802.3at PoE+ and is an ideal solution to satisfy the growing demand for higher power consuming network PDs, such as:
-  PoE PTZ speed dome cameras
-  Network devices
-  Thin clients
-  AIO (all-in-one) touch PCs, point of sale (POS) and information kiosks
-  Remote digital signage displays
-  PoE lightings

إدارة وضع إخراج الطاقة المتقدمة بتقنية 802.3bt PoE++
To meet the demand of various powered devices consuming stable PoE power, the IGS-6329 PoE++ Switch series provides five different PoE power output modes for selection.
-  90W 802.3bt PoE++ Power Output Mode
-  95W UPOE/PoH Power Output Mode
-  60W Force Power Output Mode
-  30W End-span PoE Power Output Mode
-  30W Mid-span PoE Power Output Mode
أجهزة ONVIF سهلة الاستخدام وذكية مزودة بخاصية الكشف
PLANET has newly developed an awesome feature — ONVIF Support — which is specifically designed for co-operating with video IP surveillances. From the IGS-6329 PoE++ Switch series GUI, clients just need one click to search and show all of the ONVIF devices via network application.
In addition, clients can upload floor plans to the switch, allowing to locate surveillance devices for easier inspection and planning. Moreover, clients can get real-time surveillance’s information and online/offline status, and also allows cameras PoE reboot control from GUI.
فحص ذكي لحالة تشغيل الجهاز
The IGS-6329 PoE++ Series can be configured to monitor connected PD’s status in real time via ping action. Once the PD stops working and responding, the IGS-6329 PoE++ Series will recycle the PoE port power and bring the PD back to work. It also greatly enhances the reliability in that the PoE port will reset the PD power, thus reducing administrator’s management burden.

جدول PoE لتوفير الطاقة
Under the trend of energy savings worldwide and contributing to environmental protection on the Earth, the IGS-6329 PoE++ Series can effectively control the power supply besides its capability of giving high watts power. The built-in “PoE schedule” function helps you to enable or disable PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs or enterprises save power and money.

إعادة تدوير الطاقة المجدولة
The IGS-6329 PoE++ Series allows each of the connected PoE IP cameras or PoE wireless access points to reboot at a specific time each week. Therefore, it will reduce the chance of IP camera or AP crash resulting from buffer overflow.

دعم التوجيه من الطبقة الثالثة
The IGS-6329 Series enables the administrator to conveniently boost network efficiency by configuring Layer 3 IPv4/IPv6 VLAN static routing manually, the RIP(Routing Information Protocol) or OSPF (Open Shortest Path First) settings automatically. The RIP can employ the hop count as a routing metric and prevent routing loops by implementing a limit on the number of hops allowed in a path from the source to a destination. The OSPF is an interior dynamic routing protocol for autonomous system based on link state. The protocol creates a database for link state by exchanging link states among Layer 3 switches, and then uses the Shortest Path First algorithm to generate a route table based on that database.
حلقة احتياطية، استعادة سريعة لتطبيقات الشبكة الحيوية
The IGS-6329 Series supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced ITU-T G.8032 ERPS (تبديل حماية حلقة الإيثرنت) technology, Spanning Tree Protocol (802.1s MSTP), and redundant power input system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments. In a certain simple Ring network, the recovery time of data link can be as fast as 10ms.
التواصل مع متخصصي الأمن السيبراني يساعد في تقليل المخاطر الأمنية
The IGS-6329 Series comes with enhanced cybersecurity to fend off cyberthreats and cyberattacks. It supports SSHv2, TLSv1.2 and SNMPv3 protocols to provide strong protection against advanced threats. Served as a key point to transmit data and offering over 95-watt PoE output to customer’s critical equipment in a business network, the cybersecurity feature of the IGS-6329 Series protects the switch management and enhances the security of the mission-critical network without any extra deployment cost and effort.

يوفر بروتوكول Modbus TCP اتصالاً شبكياً مرناً لأتمتة المصانع
بدعم مودبوس تي سي بي/آي بي protocol, the IGS-6329 Series can easily integrate with سكادا الأنظمة،, واجهة المستخدم الرسومية أنظمة جمع البيانات وغيرها من أنظمة جمع البيانات في أرضيات المصانع. يُمكّن ذلك المسؤولين من مراقبة محول إيثرنت الصناعي عن بُعد معلومات التشغيل, معلومات الميناء, communication status, and DI and DO status, thus easily achieving enhanced monitoring and maintenance of the entire factory.
بروتوكول التوقيت 1588 لشبكات الحوسبة الصناعية
The IGS-6329 Series is ideal for telecom and Carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for IEEE 1588 and synchronous Ethernet.

تنبيه حدث SMTP/SNMP
The IGS-6329 Series provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.

نظام إنذار فعال لحماية أفضل
The IGS-6329 Series supports a Fault Alarm feature which can alert the users when there is something wrong with the switches. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource.

مدخلات ومخرجات رقمية للإنذار الخارجي
The IGS-6329 Series supports Digital Input and Digital Output on its front panel. This external alarm enables users to use Digital Input to detect and log external device status (such as door intrusion detector), and send event alarm to the administrators. The Digital Output could be used to alarm the administrators if the IGS-6329 Series’ port shows link down, link up or power failure.

ميزات الطبقة الثانية القوية
The IGS-6329 Series can be programmed for advanced Layer 2 switch management functions such as dynamic port link aggregation, 802.1Q tagged VLAN, Q-in-Q VLAN, private VLAN, Multiple Spanning Tree Protocol (MSTP), Layer 2 to Layer 4 QoS, bandwidth control, IGMP snooping and MLD snooping. Via the aggregation of supporting ports, the IGS-6329 Series allows the operation of a high-speed trunk group that comes with multiple ports and supports fail-over as well.
الإدارة الفعالة
For efficient management, the IGS-6329 Series is equipped with console, Web and SNMP management interfaces.
-  With the built-in عبر الإنترنت توفر واجهة الإدارة هذه ميزة سهلة الاستخدام لإدارة وتكوين النظام الأساسي.
-  For نصي ويمكن الوصول إلى نظام الإدارة عبر Telnet ومنفذ وحدة التحكم.
-  For standard-based monitor and management software, it offers SNMPv3 connection which encrypts the packet content at each session for secure remote management.
أمان شبكي قوي
The IGS-6329 Series offers comprehensive Layer 2 to Layer 4- قائمة التحكم بالوصول (ACL) لتعزيز الأمن على مستوى الحافة. يمكن استخدامه لتقييد الوصول إلى الشبكة عن طريق رفض الحزم بناءً على عنوان IP المصدر والوجهة، أو منافذ TCP/UDP، أو تطبيقات الشبكة النموذجية المحددة. كما تتضمن آلية الحماية الخاصة به 802.1X Port-based و يعتمد على MAC مصادقة المستخدم والجهاز. مع شبكة VLAN خاصة يمكن منع الاتصال بين منافذ الحافة لضمان خصوصية المستخدم.
حماية متقدمة لشبكة IP
The IGS-6329 Series also provides التجسس على بروتوكول DHCP, حماية مصدر IP و فحص ARP الديناميكي تتضمن هذه الوظائف منع هجمات التجسس على عناوين IP وتجاهل حزم ARP ذات عناوين MAC غير صالحة. وبذلك، أصبح بإمكان مديري الشبكات إنشاء شبكات مؤسسية عالية الأمان بجهد ووقت أقل بكثير من السابق.
حل إيثرنت مرن وقابل للتوسيع بسرعة 10 جيجابت
10Gbps Ethernet is a big leap in the evolution of Ethernet. Each of the 10G SFP+ slots in the IGS-6329-8UP2S4X supports multiple speed و 10GBASE-SR/LR, 1000BASE-SX/LX or 2500BASE-X. With its 4-port, 10Gbps Ethernet link capability and additional 2-port 1G/2.5Gbps Ethernet link capability, the administrator now can flexibly choose the suitable SFP/SFP+ transceiver according to the transmission distance or the transmission speed required to extend the network efficiently. The IGS-6329-8UP2S4X provides broad bandwidth and powerful processing capacity.
آلية تشخيص ذكية لمرض SFP
The IGS-6329 Series supports SFP-DDM (digital diagnostic monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP and SFP+ transceivers, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.








